§ 16-352 — Definitions
Code of Ordinances of the City of Lewisville, Texas (Supp. No. 34: codified through Ordinance No. 0854-26-ORD, adopted July 6, 2026) · Lewisville City Code § 16-352
Corpus is an independent public-information project, not the official City of Lewisville website. Stable reference: corpuslaw.us/code/be80964b-0c34-4e6a-a46a-55022403ded9
Sec. 16-352. - Definitions.
For the purpose of this article, the following words and terms shall have the meanings respectively ascribed: Approved shall mean accepted by the director of public services as meeting an applicable specification stated or cited in this article, or as suitable for the proposed use. Auxiliary water supply shall mean any water supply on or available to the premises other than the approved public water supply. These auxiliary waters may include water from another public potable water supply or any natural source such as a well, spring, river, stream, etc., or used waters or industrial fluids. Auxiliary waters may be contaminated, polluted or may be objectionable and constitute an unacceptable water source over which the water utility does not have sanitary control. Backflow shall mean the reversal of the normal flow of water caused by either back-pressure or back-siphonage. Backflow preventer shall mean a device or means designed to prevent backflow. (1) Air-gap. The unobstructed vertical distance through the free atmosphere between the lowest opening from any pipe or faucet supplying water to a tank, plumbing fixture or other device and the flood level rim of such vessel. An approved air-gap shall be at least double the diameter of the supply pipe, measured vertically, above the top of the overflow rim of the vessel; and in no case less than one inch. (2) Reduced pressure principle device. An assembly of two independently acting approved check valves together with a hydraulically operating, mechanically independent pressure relief valve located between the check valves and at the same time below the first check valve. The unit shall include properly located test cocks and tightly closing shutoff valves at each end of the assembly. The entire assembly shall meet the design and performance specifications as determined by a laboratory and field evaluation program resulting in an approval by a recognized and approved testing agency for backflow prevention assemblies as listed in this text. The assembly shall operate to maintain the pressure in the zone between the two check valves at an acceptance level less than the pressure on the public water supply side of the device. At cessation of normal flow, the pressure between the two check valves shall be less than the pressure on the public water supply side of the device. In case of leakage of either of the check valves the differential relief valve shall operate to maintain the reduced pressure in the zone between the check valves by discharging to the atmosphere. When the inlet pressure is two pounds per square inch or less, the relief valve shall open to the atmosphere. To be approved these devices must be readily accessible for in-line testing and maintenance and be installed in a location where no part of the device will be submerged. (3) Double check valve assembly. An assembly of two independently operating approved check valves with tightly closing shutoff valves on each end of the check valves, plus properly located test cocks for the testing of each check valve. The entire assembly shall meet the design and performance specification as determined by a laboratory and field evaluation program resulting in an approval by a recognized and approved testing agency for backflow prevention assemblies. To be approved these devices must be readily accessible for in-line testing and maintenance. Back-pressure shall mean the flow of water or other liquids, mixtures or substances under pressure into the distribution pipes of a potable water supply system from any source other than the intended source. Back-siphonage shall mean the flow of water or other liquids, mixtures or substances into the distribution pipes of a potable water supply system from any source other than its intended source caused by the sudden reduction of pressure in the potable water supply system. Contamination shall mean an impairment of the quality of the potable water by sewage, industrial fluids or waste liquids, compounds or other materials to a degree which creates an actual or potential hazard to the public health through poisoning or through the spread of disease. Cross connection, as based upon the U.S. Department of Health, Education and Welfare's Public Health Service Publication No. 525, shall mean any physical connection or arrangement of pipes between two otherwise separate water supply systems, one of which contains potable water and the other water of unknown or questionable safety, whereby water may flow from one system to the other, the direction of flow depending on the pressure differential between the two systems. Cross connection control by containment shall mean the installation of an approved backflow prevention device at the water service connection (meter) to any customer's premises which shall be required if determined necessary by the director of public services. Cross connection, controlled. A connection between a potable water system and a nonpotable water system with an approved backflow prevention device properly installed and maintained so that it will continuously afford the protection commensurate with the degree of hazard. Cross connection section shall mean any physical connection or arrangement of piping or fixtures between two otherwise separate piping systems, one of which contains potable water and the other nonpotable water or industrial fluids of questionable safety, through which, or because of which, backflow may occur into the potable water system. This would include any temporary connections, such as swing connections, removable sections, four-way plug valves, spools, dummy sections of pipe, swivel or change-over devices or sliding multiport tube. Director of public services shall mean the individual in charge of the water utilities of the city, who is invested with the authority and responsibility for the implementation of an effective cross connection control program and for the enforcement of the provisions of this article. Hazard, degree of, is a term which is derived from an evaluation of the potential risk to public health and the adverse effect of the hazard upon the potable water system. (1) Hazard, health. Any condition, device, or practice in the water supply system and its operation which would create, or in the judgement of the director of public services or director of the health and code enforcement division of the community development department, may create a danger to the health and well-being of the water consumer. (2) Hazard, plumbing. A plumbing type cross connection in a consumer's potable water system that has not been properly protected by an approved air-gap or approved backflow prevention device. (3) Hazard, pollutional. An actual or potential threat to the physical properties of the water system or to the potability of the public or the consumer's potable water system but which would constitute a nuisance or be aesthetically objectionable or could cause damage to the system or its appurtenances, but would not be dangerous to health. (4) Hazard, system. An actual or potential threat of severe damage to the physical properties of the public potable water system or the consumer's potable water system or of a pollution or contamination which would have a protracted effect on the quality of the potable water in the system. Industrial fluids system shall mean any system containing a fluid or solution which may be chemically, biologically or otherwise contaminated or polluted in a form or concentration such as would constitute a health, system, pollutional or plumbing hazard if introduced into an approved water supply. This may include, but not be limited to, polluted or contaminated waters; all types of process waters and used waters originating from the public potable water system which may have deteriorated in sanitary quality; chemicals in fluid form; plating acids and alkalies, circulating cooling waters connected to an open cooling tower and/or cooling towers that are chemically or biologically treated or stabilized with toxic substances; contaminated natural waters such as from wells, springs, streams, rivers, bays, harbors, seas, irrigation canals or systems, etc.; oils, gases, glycerine, paraffins, caustic and acid solutions and other liquid and gaseous fluids used in industrial or other purposes or for firefighting purposes. Pollution shall mean the presence of any foreign substance (organic, inorganic or biological) in water which tends to degrade its quality so as to constitute a hazard to or impair the usefulness or quality of the water to a degree which does not create an actual hazard to the public health but which does adversely and unreasonably affect such waters of domestic use. Water, nonpotable, shall mean water which is not safe for human consumption or which is of questionable potability. Water, potable, shall mean any water which, according to recognized standards, is safe for human consumption. Water service connection shall mean the terminal end of a service connection from the public potable water system; i.e., where the public services department loses jurisdiction and sanitary control over the water at its point of delivery to the customer's water system. If a meter is installed at the end of the service connection, then the service connection shall mean the downstream end of the meter. There should be no unprotected takeoffs from the service line ahead of any meter or backflow prevention device located at the point of delivery to the customer's water system. Service connection shall also include water service connection from a fire hydrant and all other temporary or emergency water service connections from the public potable water system. Water, used, shall mean any water supplied by the public services department from a public potable water system to a consumer's water system after it has passed through the point of delivery and is no longer under the sanitary control of the public services department.
(Ord. No. 1270, § II, 1-21-85)
Ask a question about Lewisville law
Corpus searches the Lewisville sections it holds and shows the ones that match, with their citations. Free, no sign-in.