Sec. 16-355. - Policies, procedures and standards.

(a) No water service connection to any premises shall be installed or maintained by the public services department unless the water supply is protected as required by state laws and regulation and this article. Service of water to any premises shall be discontinued by the public services department if a backflow prevention device required by this article is not installed, tested and maintained, or if it is found that a backflow prevention device has been removed, bypassed, or if an unprotected cross connection exists on the premises. Service will not be restored until such conditions or defects are corrected. If required, all businesses, commercial and industrial users shall provide, maintain and routinely test an approved backflow device. The director of public services, the director of the building inspection division of the community development department, or the director of the health and code enforcement division of the community development department may require such devices as deemed necessary. Residential dwellings with any design of lawn watering devices shall require a backflow device. The device shall be determined by the director of public services, the director of the building inspection division of the community development department or the director of the health and code enforcement division of the community development department. All irregular types of lawn watering devices shall require an approved backflow device. (b) The customer's system should be open for inspection at all reasonable times to authorized representatives of the public services department or the health and code enforcement division of the community development department to determine whether cross connections or other structural or sanitary hazards, including violations of these regulations, exist. When such a condition becomes known, the director of public services or the director of the health and code enforcement division of the community development department shall deny or immediately discontinue service to the premises by providing for a physical break in the service line until the customer has corrected the condition in conformance with state and city statutes relating to plumbing and water supplies and the regulations adopted pursuant thereto. Any cost of such disconnection and the estimated cost of reconnection must be paid by the customer before service shall be restored. (c) No cross connection shall be permitted between any system of piping supplied by water from the mains of the public services department and any other source of supply, either public or private; or any secondary supplies known to be unsafe for drinking water, such as shallow wells, reused industrial supplies, raw surface water or swimming pools. (d) Where city water is used as an auxiliary supply to a roof or suction tank, which is also supplied by water from any other source, such tank shall not be of the pressure type but open. The delivery of city water shall be above the tank overflow line and controlled by an approved automatic valve. (e) It shall be unlawful, also, to maintain storage tanks supplied only with city water, unless the tanks are satisfactorily built, and covered so as to prevent the entrance of contamination. They shall also be subject to periodic inspection by the public services department and maintained in a manner wholly satisfactory to the standards and requirements of the state department of health. Pumps taking suction from the city supply, serving such building storage shall be installed or operated only upon request and/or permit from the public services department subject to their approval as to size, rate, capacity and valving arrangements. Storage tanks supplied with city water shall require an approved backflow device. In such cases, a specific backflow device shall be required at the service connection. (f) It shall be unlawful for anyone to interconnect private supplies, including deep well systems, with the city water system except as hereinafter provided: (1) Correction and maintenance, in a manner satisfactory to the state department of health and the public services department, of all existing sanitary defects in and around the private supply system. (2) Provision to be made for complete bacteriological analysis by the American Public Health Association. This requirement means not less than four analyses each month of two standard samples, or more, if the analyses warrant. (3) Approval from the city manager, the director of the building inspection division of the community development department, the director of public services and the director of the health and code enforcement division of the community development department. (4) Provision by the owner of the private system involved to pay an equitable pro rata part of the cost of all inspections and testing herein required. The rates and method of paying for the same shall be determined by the public works department subject to the approval of the city manager. (g) If required, an approved backflow prevention device shall be installed on each service line to a customer's water system at or near the property line before the first branch line leading off the service line wherever the following conditions exist: (1) In the case of a premises having an auxiliary water supply which is not or may not be of safe bacteriological or chemical quality, the public water system shall be protected against backflow from the premises by installing an approved backflow prevention device in the service line appropriate to the degree of hazard. (2) In the case of a premises on which any industrial fluids or any other objectionable substance is handled in such a fashion as to create an actual or potential hazard to the public water system, the public system shall be protected against backflow from the premises by installing an approved backflow prevention device in the service line appropriate to the degree of hazard. This shall include the handling of process waters and waters originating from the utility system which have been subject to deterioration in quality. (3) In the case of premises having internal cross-connections that cannot be permanently corrected and controlled, or intricate plumbing and piping arrangements or where entry to all portions of the premises is not readily accessible for inspection purposes, making it impracticable or impossible to ascertain whether or not dangerous cross connections exist, the public water system shall be protected against backflow from the premises by installing an approved backflow prevention device in the service line. (4) Any nonresidential building greater than one story elevation. (5) Any residential building structure greater than two stories elevation. (6) For fire lines, approved double check detector check valves must be installed on all privately maintained fire lines. Such valves shall be installed in an underground vault located on private property at the boundary of the public/private property line. Exception: When the fire line serves only the automatic fire sprinkler system, and with prior written permission from the City which shall be given at its sole discretion, the double check detector check valve may be located on the interior of the building in the fire control room. The length of the fire line as measured from the nearest edge of right of way or utility easement to the interior double check detector check valve shall not exceed 50 feet, or as otherwise approved by the Fire Code Official. (h) All boilers shall require internal protection such as an approved air-gap separation or an approved reduced pressure principle device. (i) All bypass systems shall include a required backflow device as determined by the director of public service. (j) The type of protective device required shall depend upon the degree of hazard which exists as follows: (1) In the case of any premises where there is an auxiliary water supply, the public water system shall be protected by an approved air-gap separation or an approved reduced pressure air-gap separation or an approved reduced pressure principle backflow prevention device. (2) In the case of any premises where there is water or substance that would be objectionable but not hazardous to health if introduced into the public water system, the public water system shall be protected by an approved double check valve assembly or an approved air-gap separation. (3) In the case of any premises where there is any material dangerous to health which is handled in such a fashion as to create an actual or potential hazard to the public water system, the public water system shall be protected by an approved air-gap separation or an approved reduced pressure principle backflow prevention device. Examples of premises where these conditions will exist include sewage treatment plants, sewage pumping stations, chemical manufacturing plants, hospitals, mortuaries and plating plants. (4) In the case of any premises where there are uncontrolled cross connections, either actual or potential, the public water system shall be protected by an approved air-gap separation or an approved reduced pressure principle backflow prevention device at the service connection. (5) In the case of any premises where, because of security requirements or other prohibitions or restrictions, it is impossible or impractical to make a complete in-plant cross connection survey, the public water system shall be protected against backflow from the premises by either an approved air-gap separation or an approved reduced pressure principle backflow prevention device on each service to the premises. (6) Any residential or commercial user shall provide backflow prevention on all irrigation systems. Atmospheric or pressure vacuum breakers may be utilized on irrigation systems subject to the degree of hazard and approval from the director of the building inspection division of the community development department, the director of the health and code enforcement division of the community development department and the director of public services. (k) Any backflow prevention device required herein shall be of a model and size approved by the director of the building inspection division of the community development department. The term "approved backflow prevention device" shall mean a device that has been manufactured in full conformance with the standards established by the American Water Works Association entitled: AWWA C506-78 Standards for Reduced Pressure Principle and Double Check Valve Backflow Prevention Devices and have met completely the laboratory and field performance specifications of the Foundation for Cross-Connection Control and Hydraulic Research of the University of Southern California established by: Specifications of Backflow Prevention Devices #69-2, dated March 1969, or the most current issue. Such AWWA and FCCC and HR standards and specifications have been adopted by the director of public services. Final approval shall be evidenced by a certificate of approval issued by an approved testing laboratory certifying full compliance with AWWA standards and FCCC and HR specifications. The following testing laboratories have been qualified by the director of public services to test and certify backflow preventers: Foundation for Cross-Connection Control & Hydraulic Research University of Southern California University Park Los Angeles, CA 90007 Texas A & M University Extension Services College Station, TX 77843-8000 Testing laboratories other than the laboratories listed above will be added to an approved list as they are qualified by the director of public services. Backflow preventers which may be subjected to back pressure or back siphonage that have been fully tested and have been granted a certificate of approval by such qualified laboratory and are listed on the laboratory's current list of approved backflow prevention devices may be used without further test or qualifications. (l) It shall be the duty of the user at any premises where backflow prevention devices are installed to have certified inspections and operational tests made at least once per year. In those instances where the director of public services deems the hazard to be great, he may require certified inspections at more frequent intervals. These inspections and tests shall be at the expense of the water user and shall be performed by the device manufacturer's representative, public services department personnel or by a certified tester approved by the director of public services. It shall be the duty of the director of public services to see that these tests are made in a timely manner. The user shall notify the director of public services in advance when the tests are to be undertaken so that he or his representative may witness the tests, if so desired. These devices shall be repaired, overhauled or replaced at the expense of the user whenever such devices are found to be defective. Records of such tests, repairs and overhauls shall be kept and made available to the director of public services. Records shall be kept for a period of not less than three years. If devices which service a particular line, including fire hydrants, etc., must require extended repair time, the owner shall notify the director of public services and the city fire department. (m) All fire lines shall utilize a double check-detector check, unless required otherwise by the director of public services. (n) All backflow/backsiphonage assemblies shall be installed in accordance with current public services department standards. Vaults, dimensions, etc., shall conform to local regulations. (o) All devices shall be inspected by the public services department upon completion of such project or development. (p) The director of public services shall administer an inspection program to assure that backflow prevention devices are properly maintained and operated. The director of public services, in administering the inspection program, shall take into account the complexity and operating characteristics of the devices and the protection afforded the potable water system by the devices. Reduced pressure and double check backflow prevention devices installed pursuant to the Uniform Plumbing Code (the city plumbing code) are subject to inspection and testing by the public services department. (q) Testers must successfully complete the state certification program directly related to backflow device certification. The approved tester must be registered by the public services department. (r) Should any system supplied by the city water be operated in violation of any provision of this article, it shall be the duty of the public services department to completely disconnect all service lines serving such system until this section is properly complied with. Any cost of such disconnection and the estimated cost of reconnection must be paid by the consumer before service shall be restored. If fire protection is being supplied by the noncompliant system, the public services department shall provide necessary manpower to reconnect the system in case of an emergency. However, the owner is responsible for proper protection and liability in association with all cross connection circumstances. (s) All backflow prevention devices installed as of January 1, 1985, which do not meet the requirements of this section but which were approved devices for the purposes described herein at the time of installation and which have been properly maintained shall, except for the inspection and maintenance requirements, be excluded from the requirements of these rules so long as the director of public services is assured that they will satisfactorily protect the utility system. Whenever the existing device is moved from the present location, or requires more than minimum maintenance, or when the director of public services finds that the maintenance constitutes a hazard to health, the unit shall be replaced by an approved backflow prevention device meeting the requirements of this article. (t) Test cocks shall be required on all devices. (u) Identification, including the size, model number and serial number shall be placed on the actual unit at least one-fourth inch in height and of durable marking material. (v) A plumbing permit must be obtained for installation of all backflow installations. (w) All approved backflow devices should be of the type which is basically nonremovable and installed in such a manner that removal of the device would prohibit water flow. (x) If a cross connection situation arises, the director of public services may recommend to the director of the health and code enforcement division of the community development department and the city manager a boil water order. The order would provide some protection in a hazardous situation. The time for such order shall be determined by the director of public services based upon laboratory analysis. (y) All instances of cross connection cases shall be reported to the director of public services, the director of the health and code enforcement division of the community development department and the director of the building inspection division of the department of community development. The cases shall also be submitted to the University of Southern California Foundation for Cross-Connection Control and Hydraulic Research as informational data only. (z) Internal protection surveys and system protection surveys shall be performed once each year per establishment or as determined by need or as determined by the director of public services.

(Ord. No. 4093-07-2014, § 6, 7-7-14)

Ask a question about Lewisville law

Corpus searches the Lewisville sections it holds and shows the ones that match, with their citations. Free, no sign-in.