For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 4-112 — Same—Amendments

Code of Ordinances of the City of Lewisville, Texas (Supp. No. 34: codified through Ordinance No. 0854-26-ORD, adopted July 6, 2026) · Lewisville City Code § 4-112

Corpus is an independent public-information project, not the official City of Lewisville website. Stable reference: corpuslaw.us/code/51cbadc9-beaa-43a5-adeb-45126c838bb1

Sec. 4-112. - Same—Amendments.

The city adopts the following revisions and additions to the International Plumbing Code 2021 Edition: Table of Contents, Chapter 7, Section 713; amend to read as follows: 713 Engineered Drainage Design .....7-12 Section 101.1; amend to read as follows: 101.1 Title. The regulations shall be known as the Plumbing Code of the City of Lewisville, hereinafter referred to as "this code." Section 102.8; amend to read as follows: 102.8 Referenced codes and standards. The codes and standards referenced in this code shall be those that are listed in Chapter 15 and such codes, when specifically adopted, and standards shall be considered as part of the requirements of this code to the prescribed extent of each such reference. Where the differences occur between provisions of this code and the referenced standards, the provisions of this code shall be the minimum requirements. Whenever amendments have been adopted to the referenced codes and standards, each reference to said code and standard shall be considered to reference the adopted amendments. Any reference to NFPA 70 or the National Electrical Code (NEC) shall mean the Electrical Code as adopted. Section 103; amend title to read as follows: SECTION 103 DEPARTMENT OF NEIGHBORHOOD AND INSPECTION SERVICES Section 103.1; amend to read as follows: 103.1 General. The Department of Neighborhood & Inspection Services is hereby created and the official in charge thereof shall be known as the code official. The function of the agency shall be the implementation, administration and enforcement of the provisions of this code. Section 104.8; delete. Section 104.8.1; delete. Section 109.2; amend to read as follows: 109.2 Fee schedule. The fees for all plumbing work shall be as set forth in the Lewisville City Code, Section 2-201. Section 109.3; amend to read as follows: 109.3 Work commencing before permit issuance. Any person who commences work on a mechanical system before obtaining the necessary permits shall be subject to an investigation fee, in addition to the permit fee. The investigation fee shall be equal to the amount of the permit fee as set forth in city ordinance 2-201. The payment of such investigation fee shall not exempt the applicant from compliance with all other provisions of either this code or the technical codes nor from penalty prescribed by law. Section 113.1; amend to read as follows: 113.1 General. An applicant may appeal any order, decision, or determination made by the code official relative to the application and interpretation of this code. In order to hear and decide appeals of orders, decisions, or determinations made by the code official relative to the application and interpretation of this code, the City Council shall act as the Board of Appeals. An appeal must be filed in writing with the City Manager within thirty (30) days after the date of the order, decision, or determination. After receiving an appeal in accordance with this section, the City Manager shall submit the appeal to the City Council for their consideration. The City Council's decision on the appeal shall be the final decision. Section 113.3; delete in its entirety. Section 113.4; delete in its entirety. Section 114; delete in its entirety. Section 115.1; amend and add exception to read as follows: 115.1 Notice of violation. The code official is authorized to serve a notice of violation or order on the person responsible for the erection, installation, alteration, extension, repair, removal or demolition of plumbing work in violation of the provisions of this code, or in violation of a detail statement or the approved construction documents thereunder, or in violation of a permit or certificate issued under the provisions of this code. Such order shall direct the discontinuance of the illegal action or condition and the abatement of the violation. Exception: Citations for violations of this code may be issued without requiring the issuance of a notice. Section 115.3; amend to read as follows: 115.3 Prosecution of violation. If a notice of violation is issued and is not complied with in the time prescribed by such notice, the code official is authorized to request the legal counsel of the jurisdiction to institute the appropriate proceedings at law or in equity to restrain, correct or abate such violation, or to require the removal or termination of the unlawful occupancy of the structure in violation of the provisions of this code or of the order or direction made pursuant hereto. Section 115.4; amend to read as follows: 115.4 Violation penalties. Persons who violate a provision of this code or fail to comply with any of the requirements thereof or who erect, install, alter or repair mechanical work in violation of the approved construction documents or directive of the code official, or of a permit or certificate issued under the provisions of this code, shall be subject to penalties as prescribed by Section 1-15 of the Code of Ordinances of the City of Lewisville. Each day that a violation continues shall be deemed a separate offense. Section 305.1; amend to read as follows: 305.1 Protection against contact. Metallic piping, except for cast iron, ductile iron and galvanized steel, shall not be placed in direct contact with steel framing members, concrete or cinder walls and floors or other masonry. Metallic piping shall not be placed in direct contact with corrosive soil. Where sheathing is used to prevent direct contact, the sheathing shall have a thickness of not less than 0.008 inch (8 mil) (0.203 mm) and the sheathing shall be made of approved material. Where sheathing protects piping that penetrates concrete or masonry walls or floors, the sheathing shall be installed in a manner that allows movement of the piping within the sheathing. Section 305.4.1; amend to read as follows: 305.4.1 Sewer depth. Building sewers shall be a minimum of 12 inches (304 mm) below grade. Section 306.2.4; add a new section to read as follows: 306.2.4 Plastic sewer and DWV piping installation. Plastic sewer and DWV piping installed underground shall be installed in accordance with the manufacturer's installation instructions. Trench width shall be controlled to not exceed the outside the pipe diameter plus 16 inches or in a trench which has a controlled width equal to the nominal diameter of the diameter of the piping multiplied by 1.25 plus 12 inches. The piping shall be bedded in 4 inches of granular fill and then backfilled compacting the side fill in 6-inch layers on each side of the piping. The compaction shall be to minimum of 85 percent standard proctor density and extend to a minimum of 6 inches above the top of the pipe. Section 413.4; amend to read as follows: 413.4 Required location for floor drains. Floor drains shall be installed in the following areas. 1. In public coin-operated laundries and in the central washing facilities of multiple family dwellings, the rooms containing automatic clothes washers shall be provided with floor drains located to readily drain the entire floor area. Such drains shall have a minimum outlet of not less than 3 inches (76 mm) in diameter. 2. Commercial kitchens. In lieu of floor drains in commercial kitchens, the code official may accept floor sinks. 3. Public restrooms. Section 502.3; amend to read as follows: 502.3 Water heaters installed in attics. Attics containing a water heater shall be provided . . . {bulk of paragraph unchanged} . . . at the front or service side of the water heater. The clear access opening dimensions shall be a minimum of 20 inches by 30 inches (508 mm by 762 mm), or larger where such dimensions be not less than 20 inches by 30 inches (508 mm by 762 mm) where such dimensions are large enough to allow removal of the water heater. A walkway to an appliance shall be rated as a floor as approved by the building official. As a minimum, for access to the attic space, provide one of the following: 1. A permanent stair. 2. A pull down stair with a minimum 300 lb (136 kg) capacity. 3. An access door from an upper floor level. 4. Access panel may be used in lieu of items 1, 2, and 3 with prior approval of the code official due to building conditions. Exception: The passageway and level service space are not required where the appliance is capable of being serviced and removed through the required opening. Section 504.6; amend to read as follows: 504.6 Requirements for discharge piping. The discharge piping serving a pressure relief valve, temperature relief valve or combination thereof shall: 1. Not be directly connected to the drainage system. 2. Discharge through an air gap. 3. Not be smaller than the diameter of the outlet of the valve served and shall discharge full size to the air gap. 4. Serve a single relief device and shall not connect to piping serving any other relief device or equipment. Exception: Multiple relief devices may be installed to a single T & P discharge piping system when approved by the administrative authority and permitted by the manufactures installation instructions and installed with those instructions. 5. Discharge to the floor, to the pan serving the water heater or storage tank, to a waste receptor or to the outdoors. 6. Discharge in a manner that does not cause personal injury or structural damage. 7. Discharge to a termination point that is readily observable by the building occupants. 8. Not be trapped. 9. Be installed so as to flow by gravity. 10. Terminate not more than 6 inches above and not less than two times the discharge pipe diameter above the floor or flood level rim of the waste receptor. 11. Not have a threaded connection at the end of such piping. 12. Not have valves or tee fittings. 13. Be constructed of those materials listed in Section 605.4 or materials tested, rated and approved for such use in accordance with ASME A112.4.1. 14. Be one nominal size larger than the size of the relief valve outlet, where the relief valve discharge piping is installed with insert fittings. The outlet end of such tubing shall be fastened in place. Section 504.7.1; amend to read as follows: Section 504.7.1 Pan size and drain. The pan shall be not less than 1½ inches (38 mm) in depth and shall be of sufficient size and shape to receive all dripping or condensate from the tank or water heater. The pan shall be drained by an indirect waste pipe having a diameter of not less than ½ inch (19 mm). Piping for safety pan drains shall be of those materials listed in Table 605.4. Multiple pan drains may terminate to a single discharge piping system when approved by the code official and permitted by the manufacturer's installation instructions and installed with those instructions. Section 608.1; amend to read as follows: 608.1 General. A potable water supply system shall be designed, installed and maintained in such a manner so as to prevent contamination from non-potable liquids, solids or gases being introduced into the potable water supply through cross-connections or any other piping connections to the system. Backflow preventer applications shall conform to applicable local regulations, Table 608.1, and as specifically stated in Sections 608.2 through 608.17.10. Section 608.17.5; amend to read as follows: 608.17.5 Connections to Lawn Irrigation Systems. Definitions. The following words and terms, when used in this section, have the following meanings, unless the context clearly indicates otherwise. (1) Air gap—The unobstructed vertical distance through the free atmosphere between the lowest opening from any pipe or faucet conveying water to a tank, fixture, receptor, sink, or other assembly and the flood level rim of the receptacle. The vertical, physical separation must be at least twice the diameter of the water supply, but never less that 1.0 inch. (2) As-built drawing—The final irrigation plan produced at the completion of an irrigation system installation and provided to the irrigation system's owner or the owner's representative. The as-built drawing(s) will reflect all changes made to the original irrigation plan and/or specifications during the construction process and show all aspects of the irrigation system including the dimensions, geometry, and location of all elements of the irrigation system. May be referred to as "record drawings" or "as-builts." (3) Backflow prevention—The prevention of the reversal of flow, due to back siphonage or backpressure, of nonpotable water from an irrigation system into the potable water supply. (4) Backflow prevention assembly—A mechanical assembly used to prevent backflow into a potable water system. The type of assembly used is based on the degree of hazard (health hazard or non-health hazard) and hydraulic conditions. (5) Completion of irrigation system installation—When the landscape irrigation system has been installed, all minimum standards met, all tests performed, and the irrigator is satisfied that the system is operating correctly. (6) Consulting—The act of providing advice, guidance, review or recommendations related to landscape irrigation systems. (7) Cross-connection—A physical connection between a public water system and either another supply of unknown or questionable quality, any source which may contain contaminating or polluting substances, or any source of water treated to a lesser degree in the treatment process. (8) Design—The act of determining the various elements of a landscape irrigation system that will include, but not be limited to, elements such as collecting site specific information, defining the scope of the project, defining plant watering needs, selecting and laying out emission devices, locating system components, conducting hydraulics calculations, identifying any local regulatory requirements, or scheduling irrigation work at a site. Completion of the various components will result in an irrigation plan. (9) Design pressure—The pressure that is required for an emission device to operate properly and in conjunction with head-to-head spacing requirement. Design pressure is the sum of the minimum operating pressure of an emission device to the total of all pressure losses accumulated from the emission device to the water source. (10) Double Check Valve Assembly—An assembly that is composed of two independently acting, approved check valves, including tightly closing resilient seated shutoff valves attached at each end of the assembly and fitted with properly located resilient seated test cocks. Also known as a Double Check Valve Backflow Prevention Assembly. (11) Emission device—Any device that is contained within an irrigation system and that is used to apply water. Common emission devices in an irrigation system include, but are not limited to, spray and rotary sprinkler heads, and drip irrigation emitters. (12) Employed—The state of being engaged or hired to provide irrigation services and of being in an employer-employee relationship as defined by Internal Revenue Code, 26 United States Code Service, §3212(d) based on the behavioral control, financial control, and the type of relationship involved in performing employment related tasks. (13) Exempt business owner—An owner of a business who employs a licensed irrigator to supervise the irrigation services performed by the business as referenced in V.T.C.A., Occupations Code, Ch. 1903. (14) Graywater—Wastewater from showers, bathtubs, handwashing lavatories, sinks that are used for disposal of household or domestic products, sinks that are not used for food preparation or disposal, and clothes-washing machines. Graywater does not include wastewater from the washing of material, including diapers, soiled with human excreta or wastewater that has come into contact with toilet waste. (15) Head-to-head spacing—The spacing of emission devices such that the distance between them is within the manufacturer's published radius range and the water spray reached from device to device. A deviation of 10% or less is acceptable. (16) Health hazard—A cross-connection, potential contamination hazard, or other situation involving any substance that can cause death, illness, spread of disease, or has a high probability of causing such effects if introduced into the potable drinking water supply. (17) Hydraulics—The science of dynamic and static water; the mathematical computation of determining pressure losses and pressure requirements of an irrigation system. (18) Irrigation inspector—A water district operator, governmental entity, or licensed irrigation inspector who inspects irrigation systems and performs other enforcement duties for a municipality or water district and is required to be licensed under Chapter 30 of this title (relating to Occupational Licenses and Registrations) or a licensed plumbing inspector. (19) Irrigation plan—A scaled drawing of a new landscape irrigation system to be installed. The irrigation plan shall meet all the requirements in §§ 344.60—344.65 of this title (relating to Water Conservation; Minimum Design and Installation Requirements; Completion of Irrigation System Installation; Maintenance, Alteration, Repair, or Service of Irrigation Systems; and Reclaimed Water) and is provided as an as-built drawing to the owner or owner's representative upon completion of the irrigation system installation. (20) Irrigation services—All activities involving an irrigation system including selling, designing, installing, maintaining, altering, repairing, servicing, permitting, consulting services, or connecting an irrigation system to a water supply. (21) Irrigation system—A system permanently installed on a site and that is composed of an assembly of component parts for the controlled distribution and conservation of water to irrigate, reduce dust, and control erosion in any type of landscape vegetation in any location. This term includes sprinklers and sprinkler systems used for irrigation. This term does not include a system that is used on or by an agricultural operation as defined by V.T.C.A., Agricultural Code, § 251.002. (22) Irrigation technician—A person who works under the supervision of a licensed irrigator to perform irrigation services including the connection of an irrigation system to a private or public, raw or potable water supply system or any other water supply, and who is required to be licensed under Chapter 30 (relating to Occupational Licenses and Registrations). (23) Irrigation zone—A subdivision of an irrigation system with a matched precipitation rate based on plant material type (such as turf, shrubs, or trees), microclimate factors (such as sun/shade ratio), topographic features (such as slope) and soil conditions (such as sand, loam, clay, or combination) or for hydrological control. (24) Irrigator—A person who sells, designs, offers consultations regarding, installs, maintains, alters, repairs, services or supervises the installation of an irrigation system, including the connection of such system to a private or public, raw or potable water supply system or any water supply, and who is required to be licensed under Title 30, Texas Administrative Code, Chapter 30. (25) Irrigator-in-Charge—The irrigator responsible for all irrigation work performed by an exempt business owner, including, but not limited to, obtaining permits, developing design plans, supervising the work of other irrigators or irrigation technicians, and installing, selling, maintaining, altering, repairing, or servicing a landscape irrigation system. (26) Landscape irrigation—The science of applying the necessary amount of water to promote or sustain healthy growth of plant material or turf. (27) License—An occupational license that is issued by the Texas Commission on Environmental Quality under Title 30, Texas Administrative Code, Chapter 30 to an individual that authorizes the individual to engage in an activity that is covered by Title 30, Texas Administrative Code, Chapter 30. (28) Mainline—A pipe within an irrigation system that delivers water from the water source to the individual zone valves. (29) Maintenance checklist—A document made available to the irrigation system's owner or owner's representative that contains information regarding the operation and maintenance of the irrigation system, including, but not limited to: checking and repairing the irrigation system, setting the automatic controller, checking the rain or moisture sensor, cleaning filters, pruning grass and plants away from irrigation emitters, using and operating the irrigation system, the precipitation rates of each irrigation zone within the system, any water conservation measures currently in effect from the water purveyor, the name of the water purveyor, a suggested seasonal or monthly watering schedule based on current evapotranspiration data for the geographic region, and the minimum water requirements for the plant material in each zone based on the soil type and plant material where the system is installed. (30) Major maintenance, alteration, repair, or service—Any activity that involves opening to the atmosphere the irrigation main line at any point prior to the discharge side of any irrigation zone control valve. This includes, but is not limited to, repairing or connecting into a main supply pipe, replacing a zone control valve, or repairing a zone control valve in a manner that opens the system to the atmosphere. (31) Master valve—A remote control valve located after the backflow prevention device that controls the flow of water to the irrigation system mainline. (32) Matched precipitation rate—The condition in which all sprinkler heads within an irrigation zone apply water at the same rate. (33) New installation—An irrigation system installed at a location where one did not previously exist. (34) Pass-through contract—A written contract between a contractor or builder and a licensed irrigator or exempt business owner to perform part or all of the irrigation services relating to an irrigation system. (35) Potable water—Water that is suitable for human consumption. (36) Pressure Vacuum Breaker—An assembly containing an independently operating internally loaded check valve and an independently operating loaded air inlet valve located on the discharge side of the check valve. Also known as a Pressure Vacuum Breaker Back—siphonage Prevention Assembly. (37) Reclaimed water—Domestic or municipal wastewater which has been treated to a quality suitable for beneficial use, such as landscape irrigation. (38) Records of landscape irrigation activities—The irrigation plans, contracts, warranty information, invoices, copies of permits, and other documents that relate to the installation, maintenance, alteration, repair, or service of a landscape irrigation system. (39) Reduced Pressure Principle Backflow Prevention Assembly—An assembly containing two independently acting approved check valves together with a hydraulically operating mechanically independent pressure differential relief valve located between the two check valves and below the first check valve. (40) Static water pressure—The pressure of water when it is not moving. (41) Supervision—The on-the-job oversight and direction by a licensed irrigator who is fulfilling his or her professional responsibility to the client and/or employer in compliance with local or state requirements. Also a licensed installer working under the direction of a licensed irrigator or beginning January 1, 2009, an irrigation technician who is working under the direction of a licensed irrigator to install, maintain, alter, repair or service an irrigation system. (42) Water conservation—The design, installation, service, and operation of an irrigation system in a manner that prevents the waste of water, promotes the most efficient use of water, and applies the least amount of water that is required to maintain healthy individual plant material or turf, reduce dust, and control erosion. (43) Zone flow—A measurement, in gallons per minute or gallons per hour, of the actual flow of water through a zone valve, calculated by individually opening each zone valve and obtaining a valid reading after the pressure has stabilized. For design purposes, the zone flow is the total flow of all nozzles in the zone at a specific pressure. (44) Zone valve—An automatic valve that controls a single zone of a landscape irrigation system. Valid License Required. Any person who connects an irrigation system to the water supply within the city or the city's extraterritorial jurisdiction (ETJ) must hold a valid license, as defined by Title 30, Texas Administrative Code, Chapter 30 and required by V.T.C.A., Occupations Code, ch. 1903, or as defined by Chapter 365, Title 22 of the Texas Administrative Code and required by V.T.C.A., Occupations Code, ch. 1301. Exemptions. A property owner is not required to be licensed in accordance with V.T.C.A., Occupations Code, Title 12, § 1903.002(c)(1) if he is performing irrigation work in a building or on a premises owned or occupied by the person as the person's home. A home or property owner who installs an irrigation system must meet the requirements of this ordinance and the standards contained in Title 30, Texas Administrative Code, Chapter 344 regarding spacing, water pressure, spraying water over impervious materials, rain, moisture or freeze shut-off devices or other technology, backflow prevention and isolation valves. See V.T.C.A., Occupations Code § 1903.002 for other exemptions to the licensing requirement. Permit Required. Any person installing an irrigation system within the city or its ETJ is required to obtain a permit from the city. Any plan approved for a permit must be in compliance with the requirements of this chapter. Permits for the installation on an irrigation system within the city shall be obtained from the building official of the Building Services Division of the Neighborhood and Inspection Services Department. Exemptions. (1) An irrigation system that is that an on-site sewage disposal system, as defined by V.T.C.A., Health and Safety Code § 366.002; or (2) An irrigation system used on or by an agricultural operation as defined by V.T.C.A., Agriculture Code § 251.002; or (3) An irrigation system connected to a groundwater well used by the property owner for domestic use. Backflow Prevention Methods and Devices. (a) Any irrigation system that is connected to the potable water supply must be connected through a backflow prevention method approved by the Texas Commission on Environmental Quality (TCEQ). The backflow prevention device must be installed in accordance with the laboratory approval standards or if the approval does not include specific installation information, the manufacturer's current published recommendations. (b) If there are no conditions that present a health hazard, double check valve backflow prevention assemblies may be used to prevent backflow if the device is tested upon installation and test cocks are used for testing only. (c) If a double check valve is installed below ground: (1) Test cocks must be plugged, except when the double check valve is being tested; (2) Test cock plugs must be threaded, water-tight, and made of non-ferrous material; (3) A Y-type strainer is installed on the inlet side of the double check valve; (4) There must be a clearance between any fill material and the bottom of the double check valve to allow space for testing and repair; and (5) There must be space on the side of the double check valve to test and repair the double check valve. (d) If an existing irrigation system without a backflow-prevention assembly requires major maintenance, alteration, repair, or service, the system must be connected to the potable water supply through an approved, properly installed backflow prevention method before any major maintenance, alteration, repair, or service is performed. (e) If an irrigation system is connected to a potable water supply through a double check valve, pressure vacuum breaker, or reduced pressure principle backflow assembly and includes an automatic master valve on the system, the automatic master valve shall be installed on the discharge side of the backflow prevention assembly. (f) The irrigator shall ensure the backflow prevention device is tested by a licensed Backflow Prevention Assembly Tester prior to being placed in service and the test results provided to the local water purveyor and the irrigation system's owner or owner's representative within ten business days of testing of the backflow prevention device. Specific Conditions and Cross-Connection Control. (a) Before any chemical is added to an irrigation system connected to the potable water supply, the irrigation system must be connected through a reduced pressure principle backflow prevention assembly or air gap. (b) Connection of any additional water source to an irrigation system that is connected to the potable water supply can only be done if the irrigation system is connected to the potable water supply through a reduced-pressure principle backflow prevention assembly or an air gap. (c) Irrigation system components with chemical additives induced by aspiration, injection, or emission system connected to any potable water supply must be connected through a reduced pressure principle backflow device. (d) If an irrigation system is designed or installed on a property that is served by an on-site sewage facility, as defined in Title 30, Texas Administrative Code, Chapter 285, then: (1) all irrigation piping and valves must meet the separation distances from the On-Site Sewage Facilities system as required for a private water line in Title 30, Texas Administrative Code, Section 285.91(10); (2) any connections using a private or public potable water source that is not the city's potable water system must be connected to the water source through a reduced pressure principle backflow prevention assembly as defined in Title 30, Texas Administrative Code, Section 344.50; and (3) any water from the irrigation system that is applied to the surface of the area utilized by the On-Site Sewage Facility system must be controlled on a separate irrigation zone or zones so as to allow complete control of any irrigation to that area so that there will not be excess water that would prevent the On-Site Sewage Facilities system from operating effectively. Water Conservation. All irrigation systems shall be designed, installed, maintained, altered, repaired, serviced, and operated in a manner that will promote water conservation as defined in the Definitions section of this ordinance [section 608.17.5]. Irrigation Plan Design: Minimum Standards. (a) An irrigator shall prepare a site-specific irrigation plan for each new irrigation system. A paper or electronic copy of the irrigation plan must be on the job site at all times during the installation of the irrigation system and must be consulted for installation requirements. A drawing showing the actual installation of the system is due to each irrigation system owner after all new irrigation system installations. During the installation of the irrigation system, variances from the original plan may be authorized by the licensed irrigator if the variance from the plan does not: (1) Diminish the operational integrity of the irrigation system; (2) Violate any requirements of this ordinance [section 608.17.5]; and (3) Go unnoted in red on the irrigation plan. (b) The irrigation plan must show that the irrigation system provides complete coverage of all areas to be irrigated. If there are areas that are not to be irrigated, they must be clearly identified on the irrigation plan. (c) All irrigation plans used for construction must be drawn to scale. The plan must include, at a minimum, the following information: (1) The irrigator's seal, signature, and date of signing; (2) All major physical features in accordance with subsection (b) of this section including, but not limited to, property lines, streets, sidewalks, buildings, fences, flower bed lines, and the boundaries of the areas to be watered; (3) A North arrow; (4) A legend showing the symbols used in the irrigation plan and an accurate description of what the symbol represents; (5) The zone flow measurement for each zone which includes the zone/controller station number and the zone valve size; (6) Location and type of each: (A) Controller; and (B) Sensor (for example, but not limited to, rain, moisture, wind, flow, or freeze); (7) Specifications for all irrigation system components to include, but not limited to, location, type, size, manufacturer, model number, operating pressure, flow range, radius of throw; (8) The scale used; and (9) The design pressure. (d) During the installation of the irrigation system, changes from the original plan may be authorized by the licensed irrigator if they are clearly documented in red ink on the irrigation plan and the change does not: (1) Diminish the operational integrity of the irrigation system; and (2) Violate any requirements of this chapter. (e) All changes to the irrigation plan shall be documented as an as-built drawing. Design and Installation: Minimum Requirements. (a) No irrigation design or installation shall require the use of any component, including the water meter, in a way which exceeds the manufacturer's published performance limitations for the component. (b) Spacing. (1) The maximum spacing between emission devices must not exceed the manufacturer's published radius or spacing of the device(s). The radius or spacing is determined by referring to the manufacturer's published specifications for a specific emission device at a specific operating pressure. In no instance shall the spacing exceed plus or minus 10% of the manufacturer's published radius or spacing of the device(s). (2) New irrigation systems shall not utilize above-ground spray emission devices in Landscapes that are less than 48 inches not including the impervious surfaces in either length or width and which contain impervious pedestrian or vehicular traffic surfaces along two or more perimeters. If pop-up sprays or rotary sprinkler heads are used in a new irrigation system, the sprinkler heads must direct flow away from any adjacent surface and shall not be installed closer than four inches from a hardscape, such as, but not limited to, a building foundation, fence, concrete, asphalt, pavers, or stones set with mortar. (3) Pop-up spray heads or rotary sprinkler heads must direct flow away from any adjacent surface and shall not be installed closer than four inches from a hardscape, such as, but not limited to, a building foundation, fence, concrete, asphalt, pavers, or stones set with mortar. Narrow paved walkways, jogging paths, golf cart paths or other small areas located in cemeteries, parks, golf courses or other public areas may be exempted from this requirement if the runoff drains into a landscaped area. (c) Water pressure. Emission devices must be installed to operate at the optimum or recommended sprinkler head pressure as published by the manufacturer for the nozzle and head spacing that is used. If an optimum or recommended pressure is not published, then the emission devices must be installed to operate at not below the minimum and not above the maximum sprinkler head pressure as published by the manufacturer for the nozzle and head spacing that is used. Methods to achieve the water pressure requirements include, but are not limited to, flow control valves, a pressure regulator, or pressure compensating spray heads. (d) Piping. Polyvinyl chloride (PVC) piping in irrigation systems must be designed and installed so that the flow of water in the pipe will not exceed a velocity of five feet per second. (e) Irrigation Zones. Irrigation systems shall have separate zones based on plant material type, microclimate factors, topographic features, soil conditions, and hydrological requirements. (f) Matched precipitation rate. Zones must be designed and installed so that all of the emission devices in that zone irrigate at the same precipitation rate. (g) Irrigation systems shall not spray water on or over any surfaces made of impervious material including, but not limited to, concrete, asphalt, brick, wood, stones set with mortar, walls, fences, sidewalks, and streets. (h) Master valve. When provided, a master valve shall be installed on the discharge side of the backflow prevention assembly on all new installations. (i) PVC pipe primer solvent. All new irrigation systems that are installed using PVC pipe and fittings shall be primed with a colored primer prior to applying the PVC cement in accordance with the Uniform Plumbing Code (Section 316) or the International Plumbing Code (Section 605). (j) Rain, moisture or freeze shut-off devices or other technology. All new automatically controlled irrigation systems must include sensors or other technology designed to inhibit or interrupt operation of the irrigation system during periods of moisture, rainfall or freezing. Rain, moisture or freeze shut-off technology must be installed according to the manufacturer's published recommendations. Repairs to existing automatic irrigation systems that require replacement of an existing controller must include a sensor or other technology designed to inhibit or interrupt operation of the irrigation system during periods of moisture, rainfall or freezing. As of January 1, 2010 all existing irrigation systems, except those systems for single- family properties, shall be retrofit with rain, moisture and freeze shut-off sensor devices. Existing single-family properties shall be exempt from the retrofit provision, except when repair/replacement provisions outlined above take place. (k) Isolation valve. All new irrigation systems must include an isolation valve between the water meter and the backflow prevention assembly. (l) Depth coverage of piping. Piping in all irrigation systems must be installed according to the manufacturer's published specifications for depth coverage of piping. (1) If the manufacturer has not published specifications for depth coverage of piping, the piping must be installed to provide minimum depth coverage of six inches of select backfill, between the top of the topmost pipe and the natural grade of the topsoil. All portions of the irrigation system that fail to meet this standard must be noted on the irrigation plan/as-built drawing. If the area being irrigated has rock at a depth of six inches or less, select backfill may be mounded over the pipe. Mounding must be noted on the irrigation plan and discussed with the irrigation system owner or owner's representative to address any safety issues. (2) If a utility, man-made structure, or roots create an unavoidable obstacle, which makes the six-inch depth coverage requirement impractical, the piping shall be installed to provide a minimum of two inches of select backfill between the top of the topmost pipe and the natural grade of the topsoil. (3) All trenches and holes created during installation of an irrigation system must be backfilled and compacted to the original grade. (m) Wiring irrigation systems. (1) Underground electrical wiring used to connect an automatic controller to any electrical component of the irrigation system must be listed by Underwriters Laboratories as acceptable for burial underground. (2) Electrical wiring that connects any electrical components of an irrigation system must be sized according to the manufacturer's recommendation. (3) Electrical wire splices which may be exposed to moisture must be waterproof as certified by the wire splice manufacturer. (4) Underground electrical wiring that connects an automatic controller to any electrical component of the irrigation system must be buried with a minimum of six inches of select backfill. (n) Water contained within the piping of an irrigation system is deemed to be non-potable. No drinking or domestic water usage, such as, but not limited to, filling swimming pools or decorative fountains, shall be connected to an irrigation system. If a hose bib (an outdoor water faucet that has hose threads on the spout) is connected to an irrigation system for the purpose of providing supplemental water to an area, the hose bib must be installed using a quick coupler key on a quick coupler installed in a covered purple valve box and the hose bib and any hoses connected to the bib must be labeled "non potable, not safe for drinking." An isolation valve must be installed upstream of a quick coupler connecting a hose bib to an irrigation system. (o) A licensed irrigator or a licensed irrigation technician shall be on-site at all times while the landscape irrigation system is being installed. When an irrigator is not onsite, the irrigator shall be responsible for ensuring that a licensed irrigation technician is on-site to supervise the installation of the irrigation system. (p) Valve boxes. A valve box shall be used as a durable, rigid enclosure for valves and/or any other irrigation system components that require subsurface protection. Completion of Irrigation System Installation. Upon completion of the irrigation system, the irrigator or irrigation technician who provided the on-site supervision for the installation shall be required to provide four items: (1) A final "walk through" with the irrigation system's owner or the owner's representative to explain the operation of the system; (2) The completed maintenance checklist on which the irrigator or irrigation technician shall obtain the signature of the irrigation system's owner or owner's representative and shall sign, date, and seal the checklist. If the irrigation system's owner or owner's representative is unwilling or unable to sign the maintenance checklist, the irrigator shall note the time and date of the refusal on the irrigation system's owner or owner's representative's signature line. The irrigation system owner or owner's representative will be given the original maintenance checklist and a duplicate copy of the maintenance checklist shall be maintained by the irrigator. The items on the maintenance checklist shall include but are not limited to: (A) The manufacturer's manual for the automatic controller, if one is used; (B) A seasonal (spring, summer, fall, winter) watering schedule based on either current/real time evapotranspiration data or monthly historical reference evapotranspiration (historical ET) data, monthly effective rainfall estimates, plant landscape coefficient factors, and site factors; (C) A list of irrigation system components, such as the nozzle, or pump filters, and other such components; that require maintenance and the recommended frequency for the service; and (D) The statement, "This irrigation system has been installed in accordance with all applicable state regulations as well as applicable local laws, ordinances, rules, regulations or orders. I have tested the system and determined that it has been installed according to the Irrigation Plan/As-built drawing and is properly adjusted for the most efficient application of water at this time." (3) A permanent sticker printed with waterproof ink which contains the irrigator's name, license number, company name, telephone number and the dates of the warranty period shall be affixed to each automatic controller installed by the irrigator or irrigation technician. If the irrigation system is manual, the sticker shall be affixed to the original maintenance checklist. (4) The irrigation plan/as-built drawing indicating the actual installation of the system must be provided to the irrigation system's owner or owner's representative. Maintenance, Alteration, Repair, or Service of Irrigation Systems. (a) All trenches and holes created during the maintenance, alteration, repair, or service of an irrigation system must be backfilled and returned to the original grade suitable soil free on any objects that could damage the plumbing of the irrigation system. The backfill must be compacted such that a depression does not develop. (b) Colored polyvinyl chloride (PVC) pipe primer solvent must be used on all PVC pipes and fittings used in the maintenance, alteration, repair, or service of an irrigation system in accordance with the Uniform Plumbing Code (Section 316) or the International Plumbing Code (Section 605). (c) When maintenance, alteration, repair or service of an irrigation system involves excavation work at the water meter or backflow prevention device, an isolation valve shall be installed, if an isolation valve is not present. Reclaimed Water. Reclaimed water may be utilized in landscape irrigation systems if: (a) There is no direct contact with edible crops, unless the crop is pasteurized before consumption; (b) The irrigation system does not spray water across property lines that do not belong to the irrigation system's owner; (c) The irrigation system is installed using purple components; (d) The domestic potable water line providing water to the site is connected using an air gap or a reduced pressure principle backflow prevention device, in accordance with Title 30, Texas Administrative Code, Section 290.47(f) (relating to Appendices); (e) A minimum of an eight inch by eight inch sign, in English and Spanish, is prominently posted on/in the area that is being irrigated, that reads, "RECLAIMED WATER - DO NOT DRINK" and "AGUA DE RECUPERACIÓN - NO BEBER"; and (f) Backflow prevention on the reclaimed water supply line shall be in accordance with the regulations of the city's water provider. Advertisement Requirements. (a) All vehicles used in the performance of irrigation services must display the irrigator's license number in the form of "LI _______" in a contrasting color of block letters at least two inches high, on both sides of the vehicle. (b) All forms of advertisement for irrigation services, regardless of the type of media, must display the irrigator's license number in the form of "LI _______." Any form of advertisement, including business cards, and estimates which displays an entity's or individual's name other than that of the licensed irrigator must also display the name of the licensed irrigator and the licensed irrigator's license number. Trailers that advertise irrigation services must display the irrigator's license number. (c) At the location of the permanent structure where the irrigation business is primarily conducted and irrigation records are kept, the name, mailing address, and telephone number of the commission must be prominently displayed on a legible sign and displayed in plain view for the purpose of addressing complaints. Duties and Responsibilities of City Irrigation Inspectors. A licensed irrigation inspector shall enforce the ordinance of the city, and shall be responsible for: (a) Verifying that the appropriate permits have been obtained for an irrigation system and that the irrigator and installer or irrigation technician, if applicable, are licensed; (b) Inspecting the irrigation system; (c) Determining that the irrigation system complies with the requirements of this chapter; (d) Determining that the appropriate backflow prevention device was installed, tested, and test results provided to the city; (e) Investigating complaints related to irrigation system installation, maintenance, alteration, repairs, or service of an irrigation system and advertisement of irrigation services; and (f) Maintaining records according to this chapter. Items not covered by this section 608.17.5. Any item not covered by this section 608.17.5 and required by law shall be governed by the Texas Occupations Code, the Texas Water Code, Title 30 of the Texas Administrative Code, and any other applicable state statute or Texas Commission on Environmental Quality rule. Fees. The fee for each permit shall be as set forth in the city ordinance providing the permit, inspection and license fees which is set out in Section 2-201 of the City Code. The City will collect all applicable permit fees in accordance with the city fee ordinance. Enforcement. (a) The city shall have the power to administer and enforce the provisions of this section as may be required by governing law. Any person, firm, corporation or agent who shall violate a provision of this code, or fails to comply therewith, or with any of the requirements thereof, is subject to suit for injunctive relief as well as prosecution for criminal violations, as outlined in this plumbing code. Any violation of this section 608.17.5 codified in this section is declared to be a nuisance. (b) Any person violating any provision of this section shall, upon conviction, be fined a sum not exceeding $2,000.00. Each day that a provision of this section is violated shall constitute a separate offense. An offense under this section is a Class C misdemeanor, punishable by a fine of up to $2,000.00. (c) Nothing in this chapter shall be construed as a waiver of the city's right to bring a civil action to enforce the provisions of this section and to seek remedies as allowed by law, including, but not limited to the following: (1) Injunctive relief to prevent specific conduct that violates this section 608.17.5 or to require specific conduct that is necessary for compliance with this section 608.17.5; and (2) Other available relief. Section 608.18; amend to read as follows: 608.18 Protection of individual water supplies. An individual water supply shall be located and constructed so as to be safeguarded against contamination in accordance with applicable local regulations. Installation shall be in accordance with Sections 608.18.1 through 608.18.8 of the City's plumbing code. Section 703.6; delete. Section 704.5; added to read as follows: 704.5 Single stack fittings. Single stack fittings with internal baffle, PVC schedule 40 or cast-iron single stack shall be designed by a registered engineer and comply to a national recognized standard. Section 712.5; add a new section to read as follows: 712.5 Dual Pump System. All sumps shall be automatically discharged and, when in any "public use" occupancy where the sump serves more than 10 fixture units, shall be provided with dual pumps or ejectors arranged to function independently in case of overload or mechanical failure. For storm drainage sumps and pumping systems, see Section 1113. Section 713; amend title to read as follows: SECTION 713 ENGINEERED DRAINAGE DESIGN Section 713.1; amend to read as follows: 714.1 Design of drainage system. The sizing, design and layout of the drainage system shall be designed by a registered engineer using approved design methods. Section 903.1.1; amend to read as follows: 903.1.1 Roof extension unprotected. Open vent pipes that extend through a roof shall terminate not less than six (6) inches (152 mm) above the roof. Section 1003.3.5.1; amend to read as follows: 1003.3.5.1. Sizing of grease receptacles. (a) Interceptors. Sizing of grease interceptors shall be determined by: (1) A grease interceptor is defined as a device designed and installed so as to separate and retain deleterious or undesirable matter such as light density liquids, fats, grease, and oil, from normal waste and permit normal sewage or liquid waste to discharge into the sewer system by gravity. These devices also serve to collect solids, generated by and from food preparation activities, prior to the water exiting the interceptor and entering the sanitary sewer collection system. (2) Sizing of interceptors for industrial facilities shall be determined by flow and industrial process. (3) All interceptors shall provide required capacity no less than 500 gallons and shall be at least a two chamber, watertight, vented system. The interceptors shall be constructed of impervious material acceptable to the control authority. The interceptors shall be capable of withstanding traffic loads. All interceptors shall be sized by a professional engineer or architect. (4) A four-inch inspection port with screw type lid shall be installed on the receptacle influent and effluent lines. (5) The maximum required grease interceptor for food service establishments and single service kitchens is 5,000 gallons. Larger units will be required if deemed necessary by the owner, design engineer, or controlling authority. (6) Food Establishment sizing criteria. a. Parameters. The parameters for sizing a grease interceptor are hydraulic loading and grease storage capacity, for one or more fixtures. b. Sizing Formula. The size of the interceptor shall be determined by the following formula but no less than 500 gallons in capacity: Number of meals Per peak hour 1 | × | Waste flow rate 2 | × | Retention time 3 | × | Storage factor 4 | × | Interceptor size (liquid capacity) 1. Meals Served at Peak Hour Seating Capacity × Meal Factor = Meals per Peak Hour Establishment Type | Meal Factor Fast Food (45 min) | 1.33 Restaurant (60 min) | 1 Leisure Dining (90 min) | 0.67 2. Waste Flow Rate With dishwashing machine: 6-gallon (22.17 L) flow Without dishwashing machine: 5-gallon (18.9 L) flow Single service kitchen: 2-gallon (7.6 L) flow Food waste disposer: 1-gallon (3.8 L) flow 3. Retention Times Commercial kitchen waste dishwasher: 2.5 hours Single service kitchen single serving: 1.5 hours 4. Storage Factors Fully equipped commercial kitchen 8-hour operation: 1 16-hour operation: 2 24-hour operation: 3 Single Service Kitchen: 1.5 (7) Unless a facility sells only prepackaged food, a grease interceptor is required at new food establishments. Section 1101.8; delete the exception and amend to read as follows: 1101.8 Cleanouts required. Cleanouts or manholes shall be installed in the storm drainage system and shall comply with the provisions of this code for sanitary drainage pipe cleanouts. Section 1106.1; amend to read as follows: 1106.1 General. The size of the vertical conductors and leaders, building storm drains, building storm sewers, and any horizontal branches of such drains or sewers shall be based on six (6) inches per hour rainfall rate. Section 1109; delete. Section 1202.1; delete Exceptions 1 and 2.

(Code 1990, § 3-3-2; Ord. No. 1672-2-92, § II, 2-3-92; Ord. No. 2009-3-95, § II, 3-6-95; Ord. No. 2758-12-2001, § II, 12-10-01; Ord. No. 3102-08-2004, § I, 8-2-04; Ord. No. 3264-10-2005, § I, 10-17-05; Ord. No. 3521-12-2007, § I, 12-17-07; Ord. No. 3646-02-2009, § 1, 2-2-09; Ord. No. 4038-12-2013, § 2, 12-16-13; 0242-20-ORD, § 2, 8-17-20; 0617-23-ORD, § 2, 11-6-23)

Ask a question about Lewisville law

Corpus searches the Lewisville sections it holds and shows the ones that match, with their citations. Free, no sign-in.