Sec. 4-114. - Same—Amendments.

The city adopts the following revisions and additions to the 2018 Edition of the International Fuel Gas Code. Section 101.1; amend to read as follows: 101.1 Title. These regulations shall be known as the Fuel Gas Code of the City of Lewisville, hereinafter referred to as "this code." Section 102.2; add an exception to read as follows: Exception: Existing dwelling units shall comply with Section 621.2. Section 102.8; change to read as follows: 102.8 Referenced codes and standards. The codes and standards referenced in this code shall be those that are listed in Chapter 8 and such codes, when specifically adopted, and standards shall be considered part of the requirements of this code to the prescribed extent of each such reference. Where differences occur between provisions of this code and the referenced standards, the provisions of this code shall apply. Whenever amendments have been adopted to the referenced codes and standards, each reference to said code and standard shall be considered to reference the amendments as well. Any reference to NFPA 70 or the National Electrical Code shall mean the Electrical Code as adopted. Section 103; amend title to read as follows: SECTION 103 DEPARTMENT OF NEIGHBORHOOD AND INSPECTION SERVICES Section 103.1; amend to read as follows: 103.1 General. The Department of Neighborhood and Inspection Services is hereby created and the official in charge thereof shall be known as the code official. Section 104.8; delete. Section 104.8.1; delete. Section 109.2; amend to read as follows: 109.2 Fee schedule. The fee for each permit shall be as set forth in the City Code section 2-201 providing for permit, inspection, and license fees. Section 109.4; amend to read as follows: 109.4 Work commencing before permit issuance. Any person who commences work on a mechanical system before obtaining the necessary permits shall be subject to an investigation fee, in addition to the permit fee. The investigation fee shall be equal to the amount of the permit fee as set forth in city ordinance 2-201. The payment of such investigation fee shall not exempt the applicant from compliance with all other provisions of either this code or the technical codes nor from penalty prescribed by law. Section 113.1; amend to read as follows: 113.1 Means of Appeal. An applicant may appeal any order, decision, or determination made by the code official relative to the application and interpretation of this code. In order to hear and decide appeals of orders, decisions, or determinations made by the code official relative to the application and interpretation of this code, the City Council shall act as the Board of Appeals. An appeal must be filed in writing with the City Manager within thirty (30) days after the date of the order, decision, or determination. After receiving an appeal in accordance with this section, the City Manager shall submit the appeal to the City Council for their consideration. The City Council's decision on the appeal shall be the final decision. Section 113.3; delete. Section 113.4; delete. Section 114; delete in its entirety. Section 115.2; amend and add exception to read as follows: 115.2 Notice of violation. The code official is authorized to serve a notice of violation or order on the person responsible for the erection, installation, alteration, extension, repair, removal or demolition of mechanical work in violation of the provisions of this code, or in violation of a detail statement or the approved construction documents thereunder, or in violation of a permit or certificate issued under the provisions of this code. Such order shall direct the discontinuance of the illegal action or condition and the abatement of the violation. Exception: Citations for violations of this code may be issued without requiring the issuance of a notice. Section 115.3; amend to read as follows: 115.3 Prosecution of violation. If a notice of violation is issued and is not complied with in the time prescribed by such notice, the code official is authorized to request the legal counsel of the jurisdiction to institute the appropriate proceedings at law or in equity to restrain, correct or abate such violation, or to require the removal or termination of the unlawful occupancy of the structure in violation of the provisions of this code or of the order or direction made pursuant hereto. Section 115.4; amend to read as follows: 115.4 Violation penalties. Persons who violate a provision of this code or fail to comply with any of the requirements thereof or who erect, install, alter or repair work in violation of the approved construction documents or directive of the code official, or of a permit or certificate issued under the provisions of this code, shall be subject to penalties as prescribed by Section 1-15 of the Code of Ordinances of the City of Lewisville. Each day that a violation continues shall be deemed a separate offense. Section 116.4; amend to read as follows: 116.4 Failure to comply. Any person who shall continue any work after having been served with a stop work order, except such work as that person is directed to perform to remove a violation or unsafe condition, shall be subject to penalties as prescribed by Section 1-15. Section 306.3; amend to read as follows: [M] 306.3 Appliances in attics. Attics containing appliances shall be provided . . . {bulk of paragraph unchanged} . . . side of the appliance. The clear access opening dimensions shall be a minimum of 20 inches by 30 inches (508 mm by 762 mm), or larger where such dimensions are not large enough to allow removal of the largest appliance. A walkway to an appliance shall be rated as a floor as approved by the building official. As a minimum, for access to the attic space, provide one of the following: 1. A permanent stair. 2. A pull down stair with a minimum 300 lb (136 kg) capacity. 3. An access door from an upper floor level. 4. Access panel may be used in lieu of items 1, 2, and 3 with prior approval of the code official due to building conditions. Exceptions: 1. The passageway and level service space are not required where the appliance is capable of being serviced and removed through the required opening. 2. Where the passageway is not less than 6 feet (1,829 mm) high for its entire length, the passageway shall be not greater than 50 feet (15,250 mm) in length. Section 306.5; change to read as follows: [M] 306.5 Equipment and appliances on roofs or elevated structures. Where equipment requiring access or appliances are located on an elevated structure or the roof of a building such that personnel will have to climb higher than 16 feet (4,877 mm) above grade to access, a permanent interior or exterior means of access shall be provided. Permanent exterior ladders providing roof access need not extend closer than 12 feet (2,438 mm) to the finish grade or floor level below and shall extend to the equipment and appliances' level service space. Such access shall . . . {bulk of section to read the same}. . . on roofs having a slope greater than 4 units vertical in 12 units horizontal (33-percent slope). ... {remainder of section to read the same}. Section 306.5.1; amend to read as follows: [M] 306.5.1 Sloped roofs. Where appliances, equipment, fans or other components that require service are installed on a roof having a slope of 3 units vertical in 12 units horizontal (25-percent slope) or greater and having an edge more than 30 inches (762 mm) above grade at such edge, a catwalk at least 16 inches in width with substantial cleats spaced not more than 16 inches apart shall be provided from the roof access to a level platform at the appliance. The level platform shall be provided on each side of the appliance to which access is required for service, repair or maintenance. The platform shall be not less than 30 inches (762 mm) in any dimension and shall be provided with guards. The guards shall extend not less than 42 inches (1,067 mm) above the platform, shall be constructed so as to prevent the passage of a 21-inch-diameter (533 mm) sphere and shall comply with the loading requirements for guards specified in the International Building Code. Section 401.5; add a second paragraph to read as follows: Both ends of each section of medium pressure gas piping shall identify its operating gas pressure with an approved tag. The tags are to be composed of aluminum or stainless steel and the following wording shall be stamped into the tag: "WARNING ½ to 5 psi gas pressure Do Not Remove" Section 404.12; amend to read as follows: 404.12 Minimum burial depth. Underground piping systems shall be installed a minimum depth of 18 inches (458 mm) top of pipe below grade. Section 404.12.1; delete in its entirety. Section 406.1; amend to read as follows: 406.1 General. Prior to acceptance and initial operation, all piping installations shall be inspected and pressure tested to determine that the materials, design, fabrication, and installation practices comply with the requirements of this code. The permit holder shall make the applicable tests prescribed in Sections 406.1.1 through 406.1.6 to determine compliance with the provisions of this code. The permit holder shall give reasonable advance notice to the code official when the piping system is ready for testing. The equipment, material, power and labor necessary for the inspections and test shall be furnished by the permit holder and the permit holder shall be responsible for determining that the work will withstand the test pressure prescribed in the following tests. Section 406.4; amend to read as follows: 406.4 Test pressure measurement. Test pressure shall be measured with a monometer or with a pressure-measuring device designed and calibrated to read, record, or indicate a pressure loss caused by leakage during the pressure test period. The source of pressure shall be isolated before the pressure tests are made. Mechanical gauges used to measure test pressures shall have a range such that the highest end of the scale is not greater than five times the test pressure. Spring type gauges do not meet the requirement of a calibrated gauge. Section 406.4.1; amend to read as follows: 406.4.1 Test pressure. The test pressure to be used shall be no less than 3 psig (20 kPa gauge), or at the discretion of the Code Official, the piping and valves may be tested at a pressure of at least six (6) inches (152 mm) of mercury, measured with a manometer or slope gauge. For tests requiring a pressure of 3 psig, diaphragm gauges shall utilize a dial with a minimum diameter of three and one-half inches (3½"), a set hand, 1/10 pound incrementation and pressure range not to exceed 6 psi for tests requiring a pressure of 3 psig. For tests requiring a pressure of 10 psig, diaphragm gauges shall utilize a dial with a minimum diameter of three and one-half inches (3½"), a set hand, a minimum of 2/10 pound incrementation and a pressure range not to exceed 20 psi. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure (3.48 kPa) (½ psi) and less than 200 inches of water column pressure (52.2 kPa) (7.5 psi), the test pressure shall not be less than ten (10) pounds per square inch (69.6 kPa). For piping carrying gas at a pressure that exceeds 200 inches of water column (52.2 kPa) (7.5 psi), the test pressure shall be not less than one and one-half times the proposed maximum working pressure. Diaphragm gauges used for testing must display a current calibration and be in good working condition. The appropriate test must be applied to the diaphragm gauge used for testing. Section 406.4.2; amend to read as follows: 406.4.2 Test duration. Test duration shall be held for a length of time satisfactory to the Code Official, but in no case for less than fifteen (15) minutes. For welded piping, and for piping carrying gas at pressures in excess of fourteen (14) inches water column pressure (3.48 kPa), the test duration shall be held for a length of time satisfactory to the Code Official, but in no case for less than thirty (30) minutes. Section 409.1; add Section 409.1.4 to read as follows: 409.1.4 Valves in CSST installations. Shutoff valves installed with corrugated stainless steel (CSST) piping systems shall be supported with an approved termination fitting, or equivalent support, suitable for the size of the valves, of adequate strength and quality, and located at intervals so as to prevent or damp out excessive vibration but in no case greater than 12-inches from the center of the valve. Supports shall be installed so as not to interfere with the free expansion and contraction of the system's piping, fittings, and valves between anchors. All valves and supports shall be designed and installed so they will not be disengaged by movement of the supporting piping. Section 410.1; add a second paragraph and exception to read as follows: Access to regulators shall comply with the requirements for access to appliances as specified in Section 306. Exception: A passageway or level service space is not required when the regulator is capable of being serviced and removed through the required attic opening. Section 621.2; add this new exception to read as follows: Exception: Existing approved unvented heaters may continue to be used in dwelling units, in accordance with the code provisions in effect when installed, when approved by the Code Official unless an unsafe condition is determined to exist as described in Section 108.7.

(Ord. No. 2758-12-2001, § IV, 12-10-01; Ord. No. 3264-10-2005, § I, 10-17-05; Ord. No. 3521-12-2007, § I, 12-17-07; Ord. No. 4038-12-2013, § 4, 12-16-13; 0242-20-ORD, § 4, 8-17-20; 0617-23-ORD, § 4, 11-6-23)

Ask a question about Lewisville law

Corpus searches the Lewisville sections it holds and shows the ones that match, with their citations. Free, no sign-in.