Sec. 7-613. - Technical regulations.
(a) Onsite requirements. (1) Abandoned wells. All wells shall be abandoned in accordance with the rules of the railroad commission; however, all well casings shall be cut and removed to a depth of at least three feet below the surface unless the surface owner submits a written agreement otherwise. Three feet shall be the minimum depth. No structures shall be built over an abandoned well. (2) Blowout prevention. In all cases, blowout prevention equipment shall be used on all wells being drilled, worked-over or in which tubing is being changed. Protection shall be provided to prevent blowout during oil or gas operations as required by and in conformance with the requirements of the commission and the recommendations of the American Petroleum Institute. The operator must equip all drilling wells with adequate blowout preventors, flow lines and valves commensurate with the working pressures involved as required by the commission. (3) Compliance. Operator shall comply at all times with all applicable federal, state and city requirements. (4) Discharge. No person shall place, deposit, discharge, or cause or permit to be placed, deposited or discharged, any oil, naphtha, petroleum, asphalt, tar, hydrocarbon substances or any refuse including wastewater or brine from any oil or gas operation or the contents of any container used in connection with any oil or gas operation in, into, or upon any public right-of-way, alleys, streets, lots, storm drain, pit, ditch or sewer, sanitary drain or any body of water or water course that may ultimately enter into waters of the city, state or United States. (5) Drill stem testing. All open hole formation or drill stem testing shall be done during daylight hours. Drill stem tests may be conducted only if the well effluent during the test is produced through an adequate gas separator to storage tanks and the effluent remaining in the drill pipe at the time the tool is closed is flushed to the surface by circulating drilling fluid down the annulus and up the drill pipe. The material flushed shall be secured and contained without release into the environment. (6) Dust, vibration, odors, debris on roadways. All drilling and production operations shall be conducted in such a manner as to minimize, so far as practicable, dust, vibration, or noxious odors, and shall be in accordance with the best accepted practices incident to drilling for the production of oil, gas and other hydrocarbon substances in urban areas. All equipment used shall be so constructed and operated so that, vibrations, dust, odor or other harmful or annoying substances or effect will be minimized by the operations carried on at any drilling or production site or from anything incident thereto, to the injury or annoyance of persons living in the vicinity; nor shall the site or structures thereon be permitted to become dilapidated, unsightly or unsafe. Proven technological improvements in industry standards of drilling and production in this area shall be adopted as they become available if capable of reducing factors of dust, vibration and odor. No operation at a pad site shall cause mud, dirt, debris, etc. to be deposited onto public roadways. (7) Electric lines. All operations on the site shall be powered by underground electric lines when sufficient power is available within 800 feet of the pad site. When electric utility lines are located within 800 feet of the pad site and are determined to be sufficient for operations, the operator may use fuel powered generators only as a backup in the event of a power failure. When such electric utility lines are not located within 800 feet of the pad site the operator may use fuel powered generators. (8) Electric motors. Only electric prime movers or motors shall be permitted for the purpose of pumping wells. No electric power shall be generated on location except for thermal electric generators. All electrical installations and equipment shall conform to the city ordinances and the appropriate national codes. (9) Emergency response plan. Prior to the commencement of any oil, gas or other hydrocarbons production activities, operator shall submit to the oil and gas inspector an emergency response plan establishing written procedures to minimize any hazard resulting from drilling, completion or producing of oil or gas wells. Said plan shall use existing guidelines established by the commission, Texas Commission on Environmental Quality, Department of Transportation and/or the Environmental Protection Agency. (10) Equipment painted. All production equipment on the site shall be painted a light tan color and be maintained at all times, including pumping units, storage tanks, buildings and structures. (11) Fire prevention; sources of ignition. Firefighting apparatus and supplies as approved by the fire department and required by any applicable federal, state, or local law shall be provided by the operator, at the operator's cost, and shall be maintained on the drilling site at all times during drilling and production operations. The operator shall be responsible for the maintenance and upkeep of such equipment. Each well shall be equipped with an automated valve that closes the well in the event of an abnormal change in operating pressure. All well heads shall contain an emergency shut off valve to the well distribution line. (12) Fresh water wells. It shall be unlawful to drill any oil or gas well, the center of which, at the surface of the ground, is located within 300 feet of any existing fresh water well, except for fresh water wells used solely for operation of the oil or gas well operation. The measurement shall be in a direct line from the closest well bore to the fresh water well bore. The operator of an oil or gas well shall provide the oil and gas inspector with a "pre-drilling" and "post-drilling" water analysis from any fresh water well within 800 feet of the oil or gas well. Within 180 days of its completion date, each oil or gas well shall be equipped with a cathodic protection system to protect the production casing from external corrosion. The oil and gas inspector may approve an alternative method of protecting the production casing from external corrosion. (13) Grass, weeds, trash. All drill and operation sites shall be kept clear of high grass, weeds, and trash. All landscaping shall be continuously maintained in an acceptable manner. (14) Hazardous plan. A hazardous materials management plan shall be on file with the fire marshal and the oil and gas inspector. (15) Lights. No person shall permit any lights located on any drill or operation site to be directed in such a manner so that they shine directly on public roads, adjacent property or property in the general vicinity of the operation site. To the extent practicable, and taking into account safety considerations, site lighting shall be directed downward and internally so as to avoid glare on public roads and adjacent dwellings and buildings within 500 feet. Except as may otherwise be required by the state railroad commission, all lighting shall comply with city codes regulating lighting. (16) Muffling exhaust. Exhaust from any internal combustion engine, stationary or mounted on wheels, used in connection with the drilling of any well or for use on any production equipment shall not be discharged into the open air unless it is equipped with an exhaust muffler, or mufflers or an exhaust muffler box constructed of noncombustible materials sufficient to suppress noise and prevent the escape of obnoxious gases, fumes or ignited carbon or soot. All formation fracturing operations shall be conducted during daylight hours unless the operator has notified the oil and gas inspector that fracing will occur before or after daylight hours to meet safety requirements. (17) Closed loop mud systems. A closed loop mud system shall be used in conjunction with all drilling and reworking operations for all gas well permits, unless specifically waived by the city council. (18) Private roads and drill sites. Prior to the commencement of any drilling operations, all private roads used for access to the drill site and the operation site itself shall comply with fire access lane requirements contained in the Fire Code except that the minimum unobstructed width shall be at least 12 feet wide, have an overhead clearance of 14 feet and shall be paved with asphalt or concrete capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. Said roadway shall be maintained by the operator in proper repair for the life of the well. In particular cases these requirements governing surfacing of private roads may be altered at the discretion of the oil and gas inspector after consideration of all circumstances including, but not limited to, the following: distances from public streets and highways; distances from adjoining and nearby property owners whose surface rights are not leased by the operation; the purpose for which the property of such owners is or may be used; topographical features; nature of the soil; and exposure to wind. (19) Salt water wells. No salt water wells, injection wells or disposal wells shall be located within the city. (20) Signs. a. A sign shall be immediately and prominently displayed adjacent to the public right-of-way at the gate on the temporary and permanent site fencing erected pursuant to this article. Such sign shall be durable material, maintained in good condition and, unless otherwise required by the commission, shall have a surface area of not less than two square feet nor more than four square feet and shall be lettered with the following: 1. Well name and number; 2. Name of operator; 3. The emergency 911 number; and 4. Telephone numbers of two persons responsible for the well who may be contacted in case of emergency. b. Permanent weatherproof signs reading "DANGER NO SMOKING ALLOWED" shall be posted immediately upon completion of the well site fencing at the entrance of each well site and tank battery or in any other location approved or designated by the fire marshal of the city. Sign lettering shall be four inches in height and shall be red on a white background or white on a red background. Each sign shall include the emergency notification numbers of the fire department and the operator, well and lease designations required by the commission. (21) Storage of equipment. Onsite storage is prohibited on the operation site. No equipment shall be stored on the drilling or production operation site, unless it is necessary to the everyday operation of the well. Lumber, pipes, tubing and casing shall not be left on the operation site except when drilling or well servicing operations are being conducted on the site. No vehicle or item of machinery shall be parked or stored on any street, right-of-way or in any driveway, alley or upon any operation site which constitutes a fire hazard or an obstruction to or interference with fighting or controlling fires except that equipment which is necessary for drilling or production operations on the site. The fire department shall be the entity that determines whether equipment on the site shall constitute a fire hazard. No refinery, processing, treating, dehydrating or absorption plant of any kind shall be constructed, established or maintained on the premises. This shall not be deemed to exclude a conventional gas separator or dehydrator. (22) Storage tanks. All tanks and permanent structures shall conform to the American Petroleum Institute (A.P.I.) specifications unless other specifications are approved by the city. All storage tanks shall be equipped with a secondary containment system including lining with an impervious material. The secondary containment system shall be a minimum of three feet in height and one and one-half times the contents of the largest tank in accordance with the fire code, and buried at least one foot below the surface. Drip pots shall be provided at the pump out connection to contain the liquids from the storage tank. All tanks permanently stored on site shall be painted the same light tan color as other permanent equipment unless an alternative color is deemed acceptable by the oil and gas inspector. All tanks shall be set back pursuant to the standards of the commission and the International Fire Code, but in all cases, shall be at least 25 feet from any public right-of-way or property line. Each storage tank shall be equipped with a level control device that will automatically activate a valve to close the well in the event of excess liquid accumulation in the tank. No meters, storage tanks, separation facilities, or other aboveground facilities, other than the well head and flow lines, shall be placed in a floodway. (23) Tank battery facilities. Tank battery facilities shall be equipped with a remote foam line and a lightning arrestor system. (24) Surface casing. Surface casing shall be run and set in full compliance with the applicable rules and regulations of the commission. (25) Valves. All gas well sites shall be equipped with a manual shut off valve or device in order for the city to terminate the well's production in the event of an emergency. The location of the valve shall be determined by the oil and gas inspector. (26) Bradenhead gauge. Operators shall be required to install a bradenhead gauge on all gas wells. The bradenhead gauge shall be subject to inspection by the city at all times. Pressure readings shall be provided to the gas well inspector upon request. (27) Waste disposal. Unless otherwise directed by the commission, all tanks used for storage shall conform to the following: Operator must use portable closed steel storage tanks for storing liquid hydrocarbons. Tanks must meet the American Petroleum Institute standards. All tanks must have a vent line, flame arrester and pressure relief valve. All tanks must be enclosed by a fence applicable to the issued permit classification. No tank battery shall be within 100 feet of any dwelling or other combustible structure. Drilling mud, cuttings, liquid hydrocarbons and all other field waste derived or resulting from or connected with the drilling, reworking or deepening of any well shall be processed through a closed loop mud system. All disposals must be in accordance with the rules of the commission and any other appropriate local, state or federal agency. Unless otherwise directed by the commission, waste materials shall be removed from the site and transported to an offsite disposal facility not less often than every 30 days. Water stored in onsite tanks shall be removed as necessary. All waste shall be disposed of in such a manner as to comply with the air and water pollution control regulations of the state, this article and any other applicable ordinance of the city. (28) Watchman. The operator must keep a watchman or security personnel on site during the drilling or reworking of a well when other workmen are not on the premises. (29) Painting. All production equipment shall be painted light tan in color and be maintained at all times, including wellheads, pumping units, tanks and secondary containment. When requiring painting of such facilities, the gas inspector shall consider the deterioration of the quality of the material of which such facility or structure is constructed, the degree of rust, and its appearance. The color of all tanks, fixed equipment and painted surfaces shall be the same throughout the pad site. (30) Driveway. A driveway shall be constructed, conforming to the detail titled Commercial and Industrial Driveway Layout—Truck Entrances as contained in the city's general development ordinance, at the entrance to a gas well or related site to a public road, and extending from the right-of-way to the pad site conforming to all applicable city ordinances. (b) Installation of pipelines on, under or across public property. The operator shall apply to the city for a franchise agreement on, over, under, along or across the city streets, sidewalks, alleys and other city property for the purpose of constructing, laying, maintaining, operating, repairing, replacing and removing pipelines so long as production or operations may be continued under any oil or gas well permit issued pursuant to this article. operator shall: (1) Not interfere with or damage existing water, sewer or gas lines or the facilities of public utilities located on, under or across the course of such rights-of-way. (2) Furnish to the oil and gas inspector of the city a plat showing the location of such pipelines. (3) Construct such lines out of pipe in accordance with the city codes and regulations properly cased and vented if under a street. (4) Grade, level and restore such property to the same surface condition, as nearly as practicable, as existed when operations for the drilling of the well were first commenced. No oil or gas well permit shall be issued for any well to be drilled within any of the streets or alleys of the city and/or projected streets or alleys shown by the current thoroughfare plan of the city, and no street or alley shall be blocked or encumbered or closed due to any exploration, drilling or production operations unless prior consent is obtained from the oil and gas inspector. Any consent from the oil and gas inspector shall be temporary in nature and state the number of hours and/or days that any street or alley may be blocked, encumbered or closed.
(Ord. No. 3673-05-2009, § 1, 5-4-09; Ord. No. 3809-10-2010, §§ 5—10, 10-4-10; Ord. No. 3849-04-2011, §§ 4—7, 4-4-11)
Ask a question about Lewisville law
Corpus searches the Lewisville sections it holds and shows the ones that match, with their citations. Free, no sign-in.