§ 39.05.013 — Specific standards

Code of Ordinances of the City of Lubbock, Texas (Lubbock Code of Ordinances, Charter and Unified Development Code current through Ordinance 2026-O0123 adopted September 22, 2026 (eCode360 publication LU6396, scraped 2026-11-17)) · Lubbock Unified Development Code § 39.05.013

Corpus is an independent public-information project, not the official City of Lubbock website. Stable reference: corpuslaw.us/code/b6759b5c-d8e5-4d26-87ed-3dfe66ba834d

§ 39.05.013: Specific standards.

a. Generally. In all areas of City Floodplain and special flood hazard where base flood elevation data is provided, as set forth in this Section, the following provisions apply. b. Residential construction. New construction and substantial improvement of any residential structure shall have the lowest floor (including basement), electrical, heating, ventilation, plumbing, air conditioning equipment, and other service facilities, including ductwork, elevated to the most restrictive flood protection elevation as set forth below. 1. Lowest floor elevation. A. One foot above the one percent annual chance flood elevation established by the City of Lubbock Master Drainage Plan; B. If located in a flood hazard area, the lowest floor (including basement) will be one foot above the flood elevation established by the FIRM of the Federal Emergency Management Agency (FEMA); C. Two feet above the applicable playa lake overflow elevation; D. Eighteen inches above the highest gutter elevation (or if no curb and gutter is present, one foot above top of crown) of the nearest adjacent street(s); E. Six inches above the calculated peak water surface elevation if a design waiver is granted in accordance with the Drainage Criteria Manual; or F. One foot above the 500-year 24-hour base flood elevation if located within the limits of a non-overflow playa lake. 2. Certification. A registered professional engineer, architect, or land surveyor shall submit a certificate to the Floodplain Administrator that the standard of this Subsection, as provided in Subsection b.1 of this Subsection, is satisfied. c. Nonresidential construction. New construction and substantial improvement of any commercial, industrial, or other nonresidential structure shall have the lowest floor (including basement and associated electrical and mechanical equipment) elevated to or above: 1. Lowest floor elevation. If located in a flood hazard area, the lowest floor (including basement) will be one foot above the peak water surface elevation established by the FIRM of FEMA. 2. Playa lake overflow. Two feet above the applicable playa lake overflow elevation. 3. Gutter elevation. 18 inches above the highest gutter elevation (or if no curb and gutter is present, one foot above top of crown) of the nearest adjacent street(s). 4. Peak water surface elevation. Six inches above the calculated peak water surface elevation if a design waiver is granted in accordance with the Drainage Criteria Manual. 5. Five-hundred-year flood. One foot above the 500-year 24-hour base flood elevation if located within the limits of a non-overflow playa lake or together with attendant utility and sanitary facilities, be designed so that below the base flood level the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. 6. Record. A record of that certification (floodproofing certificate), which includes the specific elevation (in relation to mean sea level) to which the structures are floodproofed, shall be maintained by the Floodplain Administrator. 7. Grading design. A finished floor elevation may be set in conjunction with a Grading Plan prepared by a licensed professional engineer that shows adequate drainage paths away from the site and with confirmation that no other flooding influences the subject site. d. Enclosures. 1. Design. New construction and substantial improvements with fully enclosed areas below the lowest floor that are usable solely for parking of vehicles, building access, or storage in an area other than a basement and which are subject to flooding shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. 2. Certification. Designs for meeting this requirement must either be certified by a registered professional engineer or architect or meet or exceed the following minimum criteria: A. A minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding shall be provided. B. The bottom of all openings shall be no higher than one foot above grade. C. Openings may be equipped with screens, louvers, valves, or other coverings or devices provided that they permit the automatic entry and exit of floodwaters. e. Manufactured homes. 1. All manufactured homes to be placed or substantially improved within zone A, AO, AH, or AE on the City's FIRM and within City Floodplains on sites that are in the following locations shall be placed on a permanent foundation so that the lowest floor of the manufactured home, electrical, heating, ventilation, plumbing, air conditioning equipment, and other service facilities, including ductwork shall be elevated to the most restrictive flood protection level as set for above: A. Outside of a manufactured home park or subdivision; B. In a new manufactured home park or subdivision; C. Existing manufactured home park or subdivision being enlarged; or D. In an existing manufactured home park or subdivision in which the manufactured home has incurred substantial damage as a result of a flood or other causes. 2. In addition, all manufactured homes to be placed or substantially improved within zone A, AO, AH, or AE on the City's FIRM and within City Floodplains on sites that are in the locations listed in Subsections A through D, above. shall be securely anchored to an anchored foundation system to resist flotation, collapse, and lateral movement, including, but not limited to over the top or frame ties to ground anchors, while complying with all other state and local regulations. Submit FEMA Elevation Certificate and engineering foundation report showing the flood protection level is satisfied. 3. Special flood hazard areas. If located in a Special Flood Hazard Area (SFHA), the lowest floor (including basement) shall be elevated to or above the most stringent of the following: A. One foot above the 500-year 24-hour base flood elevation if located within the limits of a non-overflow playa lake. B. Six inches above the calculated peak water surface elevation if a design waiver has been granted in accordance with the Drainage Criteria Manual; C. Eighteen inches above the highest gutter elevation (or if no curb and gutter is present, one foot above top of crown) of the nearest adjacent street; D. Two feet above the applicable playa lake overflow elevation; or E. One foot above the peak water surface elevation established by the FIRM; 4. Manufactured home otherwise exempted from section. Manufactured homes that are placed or substantially improved on sites in an existing manufactured home park or subdivision within a SFHA on the community's FIRM that are not subject to the provisions in this Section shall be elevated so that either: A. The lowest floor (including basement) of the manufactured home is 12 inches above the base flood elevation; or B. The manufactured home chassis is supported by reinforced piers or other foundation elements of at least equivalent strength that are no less than 36 inches in height above grade and be securely anchored to an adequately engineered anchor foundation system to resist flotation, collapse, and lateral movement. f. Recreational vehicles. Recreational vehicles placed on sites within zones of SFHA on the community's FIRM shall: 1. Duration. Be on the site for fewer than 180 consecutive days; 2. Licensed and ready for use. Be fully licensed and ready for highway use; and 3. Elevation and anchoring. Meet the elevation and anchoring requirements for manufactured homes in Subsection e., Manufactured Homes, of this Section. g. Playa lakes. Playa lakes provide critical water storage and drainage functions. All new construction and substantial improvement of structures shall follow the provisions in Division 5.3, Playa Lakes Development and Ownership.

( Ordinance 2023-O0054 adopted 5/9/2023 )

Ask a question about Lubbock law

Corpus searches the Lubbock sections it holds and shows the ones that match, with their citations. Free, no sign-in.