§ 39.05.016: Improvement and repair requirements.

Table 39.05.016-1, SI/SD FEMA Desk Reference, outlines common improvements and repairs. The measures as described in Table 39.05.016-1 are required to maintain compliance with the NFIP floodplain management requirements. If a map revision has resulted in a higher base flood elevation (BFE), a post-FIRM building shall comply based on the new BFE. Table 39.05.016-1, SI/SD FEMA Desk Reference, is reprinted and edited from SI/SD FEMA Desk Reference as amended. Table 39.05.016-1SI/SD FEMA Desk Reference SI = Substantial Improvement | SD = Substantial Damage Types of Work | Building is Pre-FIRM | Building is Post-FIRM Rehabilitation (renovate or remodel), not SI | Compliance not required | Work shall comply and shall not make the building noncompliant with any aspect of the building that was required for compliance Rehabilitation (renovate or remodel), SI | Building required to comply | Work shall comply and shall not make the building noncompliant with any aspect of the building that was required for compliance Lateral addition and rehabilitation, SI | Addition required to comply; building required to comply | Addition required to comply; building required to comply (see note below table) Lateral addition, not SI | Addition not required to comply | Additional required to be elevated to or at least the elevation of the existing lowest floor Lateral addition, SI, not structurally connected | Addition required to comply; building not required to comply | Addition required to comply; building required to comply Lateral addition, SI, structurally connected | Addition required to comply; building required to comply | Addition required to comply; building required to comply (see note below table) Vertical addition above building, not SI | Compliance not required | Work shall comply and shall not make the building noncompliant with any aspect of the building that was required for compliance Vertical addition above building, SI | Building required to comply | Work shall comply and shall not be allowed to make the building noncompliant with any aspect of the building that was required for compliance (see note below table) Repair foundation, not SI | Compliance not required | Repairs shall comply and shall not make the building noncompliant with any aspect of the building that was required for compliance Repair foundation, SI | Building required to comply | Building required to comply (see note below table) Replace/extend foundation, SI (including "elevate-in-place") | Building required to comply | Building required to comply (see note below table) Repair damage, SD | Building required to comply | Work shall comply and shall not make the building noncompliant with any aspect of the building that was required for compliance (see note below table) Reconstruct new building on existing or new foundation, SI | Reconstructed building required to comply | Reconstructed building required to comply (see note below table) TABLE NOTES: 1 | Maintain existing floor elevations. Floor elevations shall not be lowered by improvements.

( Ordinance 2023-O0054 adopted 5/9/2023 )

Ask a question about Lubbock law

Corpus searches the Lubbock sections it holds and shows the ones that match, with their citations. Free, no sign-in.