(a) An approved backflow preventor shall be installed on each service line to a customer's system at or near the property line or immediately inside the building being served; but in all cases, before the first branch line leading off the service line wherever the following conditions exist: (1) In the case of premises having an auxiliary water supply that is not, or may not be, of safe bacteriological or chemical quality; and that is not acceptable as an additional source by the city official. (2) In the case of premises on which any industrial fluids or any other objectionable substances are handled in such a fashion as to create an actual or potential hazard to the public water system. This shall include the handling of processed waters and waters originating from the utility system that have been subject to deterioration in quality. (3) In the case of premises having: a. Internal cross connections that cannot be permanently corrected and controlled; or b. Intricate plumbing and piping arrangements or where entry to all portions of the premises is not readily accessible for inspection purposes, making it impracticable or impossible to ascertain whether or not uncontrolled cross connections exist. (b) The type of backflow preventor required under subsections (a)(1), (a)(2) and (a)(3) above, shall depend upon the degree of hazard that exists as follows: (1) In the case of any premises where there is an auxiliary water supply as stated in subsection (a)(1) of this section and it is not subject to any of the following rules, the public water system shall be protected by an approved air-gap separation or an approved reduced-pressure backflow prevention assembly. (2) In the case of any premises where there is water or a substance that would be objectionable, but not a health hazard, if introduced into the public water system, an approved double check valve assembly shall protect the public water system. (3) In the case of any premises where there is any material dangerous to health that is handled in such a fashion as to create an actual or potential hazard to the public water system, the public water system shall be protected by an approved air-gap separation or an approved reduced-pressure backflow prevention assembly. Examples of premises where these conditions may exist include sewage treatment plants, sewage pumping stations, chemical manufacturing plants, hospitals, mortuaries, and plating plants. (4) In the case of any premises where there are "uncontrolled" cross-connections, either actual or potential, the public water system shall be protected by an approved air-gap separation or an approved reduced-pressure backflow prevention assembly at the service connection. (5) In the case of any premises where, because of security requirements or other prohibitions or restrictions, it is impossible or impractical to make a complete in-plant cross-connection survey, the public water system shall be protected by either an approved air-gap separation or an approved reduced-pressure backflow prevention assembly on each service to the premises. (6) In the case of any premises where, in the opinion of the utilities superintendent, an undue health hazard exists because of the presence of extremely toxic substances, the utilities superintendent may require an air-gap at the service connection to protect the public water system. This requirement will be at the discretion of the city official and is dependent on the degree of hazard.

(Ord. No. 3325, § 1, 9-20-99)

Ask a question about Mesquite law

Corpus searches the Mesquite sections it holds and shows the ones that match, with their citations. Free, no sign-in.