For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 5-288 — Use of approved backflow prevention assemblies

Code of the City of Mesquite, Texas (Supp. No. 71: codified through Ordinance No. 5259, enacted July 20, 2026) · Mesquite City Code § 5-288

Corpus is an independent public-information project, not the official City of Mesquite website. Stable reference: corpuslaw.us/code/ff3b10ba-15ee-4b6d-becb-a16a6acb4a4a

Sec. 5-288. - Use of approved backflow prevention assemblies.

(a) Any backflow prevention assembly that is required herein shall be an approved backflow prevention assembly of a model and size approved by the city official. (1) The term approved backflow prevention assembly shall mean an assembly that: a. Has been manufactured in full conformance with the standards established by the American Water Works Association ("AWWA") titled: AWWA C510-89 - Standard for Double Check Valve Backflow Prevention Assembly; AWWA C511-89 - Standard for Reduced-Pressure Principle Backflow Prevention Assembly; and b. Has met completely the laboratory and field performance specifications of the Foundation for Cross-Connection Control and Hydraulic Research ("FCCHR") of the University of Southern California established by "Specification of Backflow-Prevention Assemblies" Section 10 of the most current issue of the Manual of Cross-Connection Control. (2) The City of Mesquite has adopted said AWWA and FCCHR standards and specifications. (b) Final approval shall be evidenced by a "certificate of approval" issued by an approved testing laboratory certifying full compliance with said AWWA standards and FCCHR specifications. (1) The following testing laboratory has been qualified by the utilities superintendent to test and certify backflow prevention assemblies: Foundation for Cross-Connection Control and Hydraulic Research University of Southern California University Park Los Angeles, CA 90089 (2) Testing laboratories, other than the laboratory listed above, will be added to an approved list as the utilities superintendent qualifies them. (c) Backflow prevention assemblies that may be subjected to backpressure or backsiphonage that have been fully tested and have been granted a certificate of approval by a qualified laboratory and are listed on the laboratory's current list of approved backflow-prevention assemblies may be used without further testing or qualification.

(Ord. No. 3325, § 1, 9-20-99)

Ask a question about Mesquite law

Corpus searches the Mesquite sections it holds and shows the ones that match, with their citations. Free, no sign-in.