For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 11-1-6.03 — Lighting standards

Municipal Code of the City of Midland, Texas (Supp. No. 1, Update 2: codified through Ordinance No. 10709, enacted February 10, 2026) · Midland Municipal Code § 11-1-6.03

Corpus is an independent public-information project, not the official City of Midland website. Stable reference: corpuslaw.us/code/b8f38e36-db16-4173-a4fe-59231bb7cda4

Sec. 11-1-6.03. - Lighting standards.

(A) Purpose. The purpose of this subsection is to: 1. Reduce the problems created by improperly designed and installed outdoor lighting; 2. Reduce problems of glare on operators of motor vehicles, pedestrians and land uses; 3. Minimize light trespass; 4. Reduce the energy and financial costs of outdoor lighting by establishing regulations, which limit the area that certain kinds of outdoor lighting fixtures can illuminate; and 5. Preserve the night sky as a natural resource. (B) General Requirements. The following standards shall apply to all exterior lighting except public street lighting and other lighting (see the City's engineering standards for lighting requirements in a public right-of-way) that is specifically exempted by this subsection. 1. Shielded Light Source Required. (a) All luminaires located on nonresidential use properties shall be designed so that the light source (bulb or lamp) is completely shielded from direct view of at a point three feet above grade on the lot line abutting a residentially used or zoned property. (b) In all other instances, the light source must be completely shielded from direct view of at a point six feet above grade on the lot line. (c) See Figure 7: Shielded/Cutoff Light Source Required for examples. 2. Light Emitting Diode (LED) Lighting Required. All exterior lighting governed by this Section 11-1-6.03 Lighting Standards shall be composed of LED luminaires and no other form or type of luminaire, such as a metal halide lamp, is permitted. 3. Light Trespass (foot-candle) Limitation. All luminaires located on private property shall be designed or positioned so that the maximum illumination at the property line next to a residentially used or zoned property shall not exceed one-quarter (¼) foot-candle and shall not exceed one-half (½) foot-candle adjacent to a street right-of-way. 4. Canopy Lighting. Lighting recessed for canopies covering fueling stations at automobile service stations and drive-through facilities shall not illuminate abutting properties and the luminaires shall be designed so that the light source and lenses (bulb or lamp) are completely shielded from direct view at a point five feet above the grade on the lot line. 5. Outdoor Advertising Lighting. Outdoor advertising lighting shall conform to all applicable laws, ordinances, rules, and regulations. [image omitted; see the official code] Figure 7: Shielded/Cutoff Light Source Required 6. Wall or Roof Lighting. (a) Wall or roof lighting may be used to illuminate the pedestrian walkways, entrance areas and yard areas within 30 feet of the building. (b) No wall or roof lighting shall be used to illuminate areas for motor vehicle parking or access unless the Building Official finds the following: i. That the proposed lighting is not in conflict with the stated purpose; ii. That the proposed lighting will not unreasonably harm or restrict public health, safety and welfare or create a nuisance; and iii. The proposed lighting will not result in an impairment of vision creating a hazard for vehicular or pedestrian traffic. 7. Open Area Used for Motor Vehicle Parking, Storage or Access. (a) Any open area used for motor vehicle parking, storage or access may be illuminated with freestanding luminaires. (b) Freestanding luminaires are permitted to be a maximum of 30 feet in height. (c) When a luminary is located within 100 feet of a residentially used or zoned property, the maximum permitted luminaires height shall be 20 feet. (d) All luminaires must have a total cutoff angle equal to or less than 90 degrees. (e) The use of exterior lighting with a cutoff angle greater than 90 degrees shall be permitted only when the Building Official finds the following: i. That the proposed lighting is not in conflict with the stated purpose; ii. That the proposed lighting will not unreasonably harm or restrict public health, safety and welfare or create a nuisance; and iii. The proposed lighting will not result in an impairment of vision creating a hazard for vehicular or pedestrian traffic. 8. Signs. Signs shall conform to all applicable laws, ordinances, rules, and regulations. 9. Flags, Statues, and Other Similar Objects. Outdoor light fixtures used to illuminate flags, statues, or any other objects mounted on a pole, pedestal, or platform shall use a very narrow cone of light for the purpose of confining the light to the object of interest and minimize spill-light and glare. 10. Buildings. Building façades and architectural features of buildings may be floodlighted when the following conditions are met: (a) Illumination Levels. i. Engineering Society of North America Lighting Handbook. The illumination levels contained in the Illuminating Engineering Society of North America Lighting Handbook, as amended from time to time, shall be used as a guide for providing adequate and safe illumination levels. ii. Private or Public Development Project. The Building Official may require conformance with the illumination levels contained in the Lighting Handbook, Illuminating Engineering Society of North America as part of the review and approval of a private or public development project. (b) Method of Measurement. i. Light Measuring Meter. a. The light measuring meter shall have a color and cosine-corrected sensor with multiple scales and shall read within an accuracy of plus or minus five percent. b. It shall be tested, calibrated, and certified by an independent commercial photometric laboratory or the manufacturer within one year of its use. ii. Measurements/Readings. a. Illumination levels shall be measured in foot-candles with a meter sensor in a horizontal position at an approximate height of three feet above grade. b. Maximum illumination readings are to be taken directly beneath the luminaires. (c) Exterior Lighting Plan. i. Submission. a. Applicability. A lighting plan shall be required anytime exterior lighting is proposed, or modified, that is associated with a use of greater intensity than a one or two family dwelling. b. Submission Official. The lighting plan shall be submitted to the Building Official. c. Submission Criteria. The submission shall contain but shall not necessarily be limited to the following: (i) Plans indicating the location of the exterior lighting on the premises, and the type of illuminating devices, fixtures, lamps, supports, reflectors, and other devices; (ii) Description of the illuminating devices, fixtures, lamps, supports, reflectors, and other devices and the description may include, but is not limited to, catalog cuts by manufacturers and drawings (including sections where required) and height of the luminaires; and (iii) Photometric plan and data sheets, such as that furnished by manufacturers, or similar to that furnished by manufacturers, showing the angle of cut off or light emissions. d. Once the plan is approved by the Building Official, the exterior lighting of the property shall conform to the approved lighting plan. e. A lighting plan required by Section 11-1-6.03.E Exterior Lighting Plan shall expire at the same time that the approved Site Plan for which it was submitted expires. ii. Lamp or Fixture Substitution. Should any outdoor light fixture or the type of light source therein be changed after the issuance of the Building Permit or Certificate of Occupancy and Compliance, a change request with adequate information, as required in Section 11-1-6.03.E.1 above herein, to ensure compliance with the Zoning Ordinance must be submitted to the Building Official for review and approval prior to the substitution. (d) Prohibited. i. Prohibited Lighting Fixtures. a. "Cobra head" type lighting fixtures having dished or "drop" lenses or refractors shall be prohibited. b. See Figure 7: Shielded/Cutoff Light Source Required for examples. ii. Lights Prohibited from Flickering or Flashing. Flickering or flashing lights shall be prohibited. (e) Exemptions. The following are exempt from the standards contained in the Zoning Ordinance. i. Decorative Seasonal Lighting. Decorative seasonal lights used for temporary purposes. ii. Residential Dwellings. a. Lighting for residential dwellings, provided that: (i) The lamps have a power rating of less than or equal to 75 watts, (ii) A cutoff component is incorporated in the design of the luminaires, and (iii) The lighting level at the property line shall not exceed the maximum level specified within the Zoning Ordinance. b. The maximum lighting level at the property line may be exceeded in cases where the lamp is turned on and off by a motion sensor and the lamp is not on for a continuous period exceeding ten minutes. iii. Luminous Tube Lighting. Luminous tube lighting is exempt from the Zoning Ordinance. iv. Specific Signs. Signs of the type constructed of translucent materials and wholly illuminated from within are exempt from the shielding requirement. v. Temporary Emergency Lighting. Temporary emergency lighting used by police, fire fighters, or other emergency services, as well as all vehicular luminaires. vi. Hazard Warnings. Hazard warning luminaires, which are required by federal and state regulatory agencies. vii. Residential Party Lights. a. Residential party lights for social gatherings. Such temporary outdoor lighting includes, but is not limited to, strings of lights and lanterns. b. The party lights shall be removed within a two weeks after a social gathering. viii. Specific Recreation. a. Because of their unique requirement for nighttime visibility and their limited hours of operations, ball diamonds, playing fields and tennis courts are exempted from the general standards of this section. b. Lighting for these outdoor recreational uses shall be shielded to minimize light and glare from spilling over onto a residentially used or zoned property. c. The maximum permitted illumination at the residential property line shall not exceed two foot-candles. iv. Public Street or Sidewalk Projects. The City Council may vary from the requirements of this section as part of the approval of public street or sidewalk projects.

(Ordinance 9920, sec. 1,(Exh. A) adopted 5/28/2019)

Ask a question about Midland law

Corpus searches the Midland sections it holds and shows the ones that match, with their citations. Free, no sign-in.