§ 11-1-6.05 — Building design standards for nonresidential buildings
Municipal Code of the City of Midland, Texas (Supp. No. 1, Update 2: codified through Ordinance No. 10709, enacted February 10, 2026) · Midland Municipal Code § 11-1-6.05
Corpus is an independent public-information project, not the official City of Midland website. Stable reference: corpuslaw.us/code/12fbdf46-b615-493d-a8a8-17632cb48693
Sec. 11-1-6.05. - Building design standards for nonresidential buildings.
(A) Purpose and Intent. This section of the Zoning Ordinance is intended to ensure that all nonresidential buildings shall be compatible with the architectural character and design in terms of style, mass, height, roof design, and other exterior elements. (B) Applicability. All nonresidential buildings shall comply with this Section 11-1-6.05, except buildings within the LI, Light Industrial District or the HI, Heavy Industrial District. (C) Nonresidential Building Orientation. Any building (excluding parking garages) within view of a public Right-of-Way shall either face such Right-of-Way or shall have a façade facing such Right-of-Way in keeping with the character of the Front Façade. (D) Nonresidential Design Elements Requirements. 1. Following is a list of design elements that, based upon the size of a building (see Section 11-1-6.05.D.2 below), shall be incorporated into a building's design: Table 12: Menu of Nonresidential Design Elements 1 | Canopies, awnings, or porticos 2 | Overhangs 3 | Recesses or projections 4 | Arcades 5 | Peaked roof forms 6 | Arches 7 | Outdoor patios 8 | Display windows 9 | Architectural details; such as, tile work or moldings, integrated into the building façade 10 | Integrated planters or wing walls that incorporate landscape and sitting areas 11 | Offsets, reveals or projecting ribs used to express architectural or structural bays 2. A building's floor area shall determine the minimum number of required design elements implemented in its construction as set forth in the table below: Table 13: Required Minimum Number of Design Elements Building Square Footage | Minimum Number of Design Elements 0—50,000 s.f. | 3 50,001—100,000 s.f. | 5 Over 100,001 s.f. | 7 (E) Nonresidential Front Façade Entry Requirements. 1. A Front Façade shall be articulated and designed to present a distinctive entry presence, emphasizing the building's entry point along the façade. 2. Each building shall provide a sheltered entry. (F) Nonresidential Building Articulation. Façade depth and height articulation shall be required on the front façade of a building, per the following: 1. Depth articulation of at least three feet shall be required for every 50 feet of building façade length. Depth articulation applies only below the roofline. 2. Height articulation for flat roofs of at least five feet shall be required for every 50 feet of building façade length. Pitched roofs do not require height articulation. (G) Tripartite Building Design/Composition. 1. Buildings shall incorporate a tripartite building composition (base, middle and top). 2. The tripartite shall be proportioned to the other elements of the tripartite and the overall structure. [image omitted; see the official code] Figure 8: Tripartite Building Design/Composition (H) Roof Design Standards. 1. All structures shall be constructed with a pitched roof, flat roof with a parapet, true mansard roof, or any combination thereof. 2. All flat roof surfaces shall be screened from ground level views so that such roof surfaces are not visible. 3. Roofs of stairwells and elevator machine rooms and other similar spaces shall be exempt from roofing design standards so long as they are not visible from ground level. For the purpose of this paragraph, visible shall be defined as "capable of being seen at a height of six feet while standing at the highest grade on the property line."
(Ordinance 9920, sec. 1,(Exh. A) adopted 5/28/2019)
Ask a question about Midland law
Corpus searches the Midland sections it holds and shows the ones that match, with their citations. Free, no sign-in.