Sec. 8-151. - Standards and specifications.

(a) Materials, equipment, safety standards. Conformity of electrical equipment with the applicable standards of the Underwriters' Laboratories, Inc., ANSI or NEC, shall be prima facie evidence that such equipment is reasonably safe to persons and properties. (b) Installations creating hazards to fire protection and prevention. No wires shall be installed, operated or maintained over any street, alley, sidewalk or building: (1) Which may foreseeably interfere with the work of the fire department in the use of ladders or other apparatus; or (2) Which shall obstruct or render hazardous the use of fire escapes. On complaint of the city fire marshal, said wires shall be removed or properly rearranged. (c) Special electrical circuit requirements. The following additional requirements shall be met for all new construction: (1) All circuits shall have conductors sized in accordance with article 310 of the NEC. No conductor smaller than No. 12 copper American wire gauge size, shall be used in any electrical work as covered by this Code, except the following as approved by the NEC: a. Pendant and portable cords; b. No. 14 for control circuits, operating contractors, relays, etc.; c. Wiring within display cases; d. Wiring for system covered by chapter 7 of the NEC; (2) All panels must be large enough to accommodate the present load requirements and have at least two spaces for future use. (3) All 125-volt, single phase 15 or 20 ampere rated devices installed in commercial and industrial installations shall be of the nonresidential type or shall be 20-ampere rated only. (4) Temporary service for construction sites are required to have a driven ground rod. (5) Flexible metal conduit smaller than one-half-inch electrical trade size shall not be permitted. (6) Kerneys or split bolt connectors shall not be allowed for taps in electrical services and gutters. Only blocks and couple taps are permitted. (7) All building services shall have a UFER grounded and be grounded by Art. 250 of NEC. (8) All closets and storage areas that are over 48 inches deep or more shall have a luminaire controlled by a switch that is readily accessible and complies with Section 410.16 of the NEC. (d) Construction, rodent proof. All exterior wall openings around electrical cables and conduits shall be closed with cement mortar, concrete masonry, or other approved material to prevent the passage of rodents. (e) Commercial buildings. (1) All commercial buildings shall be wired in raceways. However, this provision shall not apply to pre-existing wiring in buildings which were originally constructed and used as residential-use buildings and thereafter converted to commercial usage. (2) For each panel in commercial construction, a minimum of one spare one-inch raceway shall be installed from the panel to an accessible location in the attic or crawlspace for recessed panels only. (3) All thermostat wire, doorbell wire, fire alarm wire and other wire 50 volts or less must be run in conduit, with the exception of plenum cable. (f) Special safety measures. (1) Color coding of conductors. a. Single phase, 120/240-Volt System. Phase A | Black B | Red Neutral | White b. Three phase, 120/240-volt center tap Delta System. Phase A | Black B | Red C | Orange (high leg) Neutral | White c. Three phase, 480-volt Delta System. Phase A | Brown B | Yellow C | Purple d. Three phase, 120/208-volt WYE System. Phase A | Black B | Red C | Blue Neutral | White e. Three phase, 277/480-volt WYE System. Phase A | Brown B | Yellow C | Purple Neutral | Natural Gray (2) Except upon written permission of the chief electrical inspector, no electrical conductor of any nature shall be installed nearer than three inches to any metal pipe or duct which could operate in excess of 120 degrees Fahrenheit. (3) Doorbell transformers must be mounted in an attic, heater closet, bedroom closet or other space where air can flow freely around the transformer. The transformer shall not be covered after it has been mounted. (4) It will not be acceptable to use flexible metal conduit outside. Liquid-tight flexible conduit or liquid-tight flexible nonmetallic conduit are considered acceptable. (g) Smoke detector systems. (1) Every dwelling and every dwelling unit within an apartment house, condominium or town house, and every guest or sleeping room in a child-care facility, motel, hotel or dormitory, shall be provided with an approved listed smoke detector in accordance with V.T.C.A., Property Code § 92.251 et seq. (2) Detectors shall be listed and meet the installation requirements of NFPA 74 and NFPA 72E and be hard wired with battery pack in series where all alarms will be activated. (h) Engineer seal required. In accordance with the Texas Engineering Practice Act, all drawings pertaining to non-dwelling construction projects of 5,000 square feet or more shall bear the seal of an engineer registered in the state. The chief electrical inspector is hereby authorized to require, at his discretion, said seal to be placed upon drawings for non-dwelling construction projects of lesser square footage. (i) Use of unapproved appliance prohibited. It shall be unlawful for any person within the city to install electrical equipment or appliances which have not been: (1) Endorsed by the Underwriters' Laboratories, Inc., or other nationally recognized standards association; or (2) Approved by the chief electrical inspector.

(Ord. No. O-2017-4343, § I, 4-27-2017; Ord. No. O-2018-5866, § IX, 9-27-2018; Ord. No. O-2019-0466, § I, 11-26-2019; Ord. No. O-2024-116, § II, 5-9-2024)

Ask a question about Round Rock law

Corpus searches the Round Rock sections it holds and shows the ones that match, with their citations. Free, no sign-in.