For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 8-27 — General Standards

Code of Ordinances of the City of Sugar Land, Texas (Supp. No. 56: codified through Ordinance No. 2403, adopted June 16, 2026) · Sugar Land Development Code § 8-27

Corpus is an independent public-information project, not the official City of Sugar Land website. Stable reference: corpuslaw.us/code/4800f28f-c16d-433b-a81f-f889396805d0

Sec. 8-27. - General Standards.

In all areas of special flood hazards, the following provisions are required for all new construction and substantial improvements: A. All new construction or substantial improvements shall be designed (or modified) and adequately anchored to prevent flotation, collapse or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy; B. All new construction or substantial improvements shall be constructed by methods and practices that minimize flood damage; C. All new construction or substantial improvements shall be constructed with materials resistant to flood damage; D. All new construction or substantial improvements must be designed and constructed with electrical, heating, ventilation, plumbing, air conditioning equipment, and other service facilities, including machinery or equipment placed within attached garages, elevated to at least 1 foot above the BFE so as to prevent water from entering or accumulating within the components during conditions of flooding; E. All new and replacement water supply systems shall be designed to minimize or eliminate infiltration of flood waters into the system; F. New and replacement sanitary sewage systems shall be designed to minimize or eliminate infiltration of flood waters into the system and discharge from the systems into flood waters; G. On-site waste disposal systems shall be located to avoid impairment to them or contamination from them during flooding; H. The lowest elevation of the first floor of all structures and buildings must be constructed at least 2 feet above the 100-year floodplain base flood elevation as established by Atlas 14, Vol. 11, Texas, 1.5 feet above adjacent natural ground, or 1 foot above top of curb, whichever is the higher elevation shown on the latest FIRM map panels or the latest available data provided by the City if there is no FIRM that provides for a BFE as indicated in Section 8.3.9. All public streets must to designed so that the lowest top of curb elevation is equal to or above the 100-year floodplain elevation, or, in lieu thereof, the developer may provide documentation satisfactory to the City to show that the lowest public street top of curb elevation is not exceeded by the 100-year floodplain elevation for more than 4 hours. The 100-year floodplain is the 100-year water surface elevation in the outfall channel, receiving stream, or detention facility designated to receive storm runoff from the proposed development as established by Atlas 14, Vol. 11, Texas. For leveed areas subject to multiple outlet condition analyses under the City's Design Standards and the Fort Bend County Drainage District drainage criteria, the requirements in this paragraph must to be met for all conditions. Special consideration may be given to tracts containing natural aesthetic amenities within existing developed areas and served by existing outfall drainage facilities, where the addition of fill would result in the destruction of those amenities and for which there is no other feasible method to meet the aforementioned criteria. When base flood elevation data is not available in accordance with Section 8-12 of this Chapter, and reliable base flood elevation data and floodway data is not available from a federal, state or other source, a floodplain study must be provided by a professional engineer that establishes the base flood elevation (BFE) and the floodplain and floodway boundaries prior to the City issuing a development permit; and I. Any encroachment, including fill, new construction, substantial improvement, or other development within a special flood hazard area, must provide compensatory floodplain storage that is at least equal to the amount of encroachment within at a location within the same watershed, within ½ mile of the encroachment, and within the corporate limits of the City. Mitigation plans that do not meet these conditions must be supported by an engineering study and a recommendation prepared by a registered professional engineer and must be approved by the Floodplain Administrator.

(Ord. No. 1979, § 2, 12-2-14; Ord. No. 2192, § 5, 5-5-20; Ord. No. 2248, § 6, 11-2-21)

Ask a question about Sugar Land law

Corpus searches the Sugar Land sections it holds and shows the ones that match, with their citations. Free, no sign-in.