§ 11-62 — Specific standards
Code of Ordinances of the City of Waco, Texas (Supp. No. 88: codified through Ordinance No. 2026-250, enacted April 21, 2026) · Waco City Code § 11-62
Corpus is an independent public-information project, not the official City of Waco website. Stable reference: corpuslaw.us/code/a23ca84b-a026-4cf7-a9b1-69b717f20557
Sec. 11-62. - Specific standards.
In all areas of special flood hazard where base flood elevation data has been provided, as set forth in subsections 11-2(b) or 11-63(c), the following provisions are required: (1) Residential construction. New construction and substantial improvement of any residential structure shall have the lowest floor (including basement) elevated to two feet or more above the base flood elevation, together with attendant utility and sanitary facilities. A registered professional engineer, architect or land surveyor shall submit a certification to the floodplain administrator that the standard of this subsection as proposed in subsection 11-39(1) is satisfied. (2) Nonresidential construction. New construction and substantial improvements of any commercial, industrial or other nonresidential structure shall either have the lowest floor (including basement) elevated to two feet or more above the base flood level or, together with attendant utility and sanitary facilities, be designed so that below two feet above the base flood level, the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. A registered professional engineer or architect shall develop and/or review structural design, specifications and plans for the construction and shall certify that the design and methods of construction are in accordance with accepted standards of practice, as outlined in this subsection. A record of such certification, which includes the specific elevation (in relation to mean sea level) to which such structures are floodproofed, shall be maintained by the floodplain administrator. (3) Enclosures. New construction and substantial improvements, with fully enclosed areas below the lowest floor that are usable solely for parking of vehicles, building access or storage in an area other than a basement and that are subject to flooding, shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. Designs for meeting this requirement must either be certified by a registered professional engineer or architect or meet or exceed the following minimum criteria: a. A minimum of two openings on separate walls having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding shall be provided. b. The bottoms of all openings shall be no higher than one foot above grade. c. Openings may be equipped with screens, louvers, valves or other coverings or devices, provided that they permit the automatic entry and exit of floodwaters. (4) Manufactured homes. a. All manufactured homes to be placed within Zone A shall be installed using methods and practices which minimize flood damage. For the purposes of this requirement, manufactured homes must be elevated and anchored to resist flotation, collapse or lateral movement. Methods of anchoring may include, but are not limited to, use of over-the-top or frame ties to ground anchors. This requirement is in addition to applicable state and local anchoring requirements for resisting wind forces. b. All manufactured homes shall be in compliance with subsection 11-62(1). c. All manufactured homes to be placed or substantially improved within Zones AH and/or AE on the community's FIRM shall be elevated on a permanent foundation, such that the lowest floor of the manufactured home is at least two feet or more above the base flood elevation and be securely anchored to an adequately anchored foundation system, in accordance with the provisions of this subsection. (5) Recreational vehicles. a. Require that recreational vehicles placed on sites within Zones A, AE, and/or AH on the community's FIRM either: i. Be on the site for fewer than 180 consecutive days; and be fully licensed and ready for highway use; or ii. Meet the permit requirements of section 11-39, and the elevation and anchoring requirements for "manufactured homes" in subsection (4) of this section. A recreational vehicle is ready for highway use if it is on its wheels or jacking system, is attached to the site only by quick disconnect type utilities and security devices, and has no permanently attached additions. b. Park model recreational vehicles shall meet the requirements for manufactured homes. (6) Detached accessory structures used only for parking of vehicles and storage are permitted at grade if: a. It is not larger than a one-story two car garage and walls have flood openings in compliance with requirements in section 11-62(3); b. Anchored to resist flotation, collapse and lateral movement; c. Flood damage-resistant materials are used below two feet above the base flood elevation; and d. Mechanical, electrical, and utility equipment are elevated two feet above the base flood elevation.
(Ord. No. 2013-486, § 2, 8-20-13; Ord. No. 2025-477, § 4, 6-17-25)
Ask a question about Waco law
Corpus searches the Waco sections it holds and shows the ones that match, with their citations. Free, no sign-in.
