§ 14-186 — Recirculation systems; filter rooms
Code of the City of Chesapeake, Virginia (Supp. No. 148: codified through Ordinance No. 26-O-071, enacted August 11, 2026) · Chesapeake City Code § 14-186
Corpus is an independent public-information project, not the official City of Chesapeake website. Stable reference: corpuslaw.us/code/44a07c8a-3a37-478d-af10-6dfffa0c6118
Sec. 14-186. - Recirculation systems; filter rooms.
(a) All swimming pools shall be equipped with a recirculation system consisting of pumps, hair and lint catchers, filters, disinfection equipment and necessary pipe connections to the inlets and outlets. Adequate provisions shall be made for backwashing filters. (b) Public pools, spas/hot tubs and wading pools shall have maximum turnover rates as follows: Public pools: Six hours. Public spas/hot tubs: Thirty minutes. Wading pools: One hour. (c) Filter room. Public pools shall be provided with a structure or room to contain the filtration equipment, pumps and other recirculation system appurtenances, and disinfection equipment. The room shall be finished in a light color and be constructed of materials, which are impervious to water, and chemicals necessary for the operation of the pool. Adequate illumination of 20 foot-candles measured 24 inches (61 centimeters) above floor level, shall be provided by National Electric Code (NEC) approved vapor-proof lighting fixtures. The floor of the filter room shall be designed to provide for an adequate drainage with a minimum floor slope of 1:50 and a maximum of 1:24 to the drain and shall be kept dry, particularly in the vicinity of electrical panels. All enclosures shall be located at or above ground level. The enclosure shall be provided with ducts from the bottom of the enclosure to the atmosphere in an unrestricted area, a motor-driven exhaust fan capable of producing at least one air change per minute, and louvers of good design near the top of the enclosure for admitting fresh air. Warning signs shall be posted on the doors. Doors to the chlorine room shall open away from the pool. Electrical switches for control of artificial lighting and ventilation shall be on the outside of the enclosure adjacent to the door. The provision of any facility for discharging filter backwashing water into the filter room floor is prohibited. The room shall be provided with a door or doors of sufficient width to permit the removal of equipment, and shall be capable of being secured against entry by unauthorized persons. The entrance to the filter room shall be adjacent to the pool area or so located that the operator can enter the room without having to exit the enclosed pool area. Protective clothing, i.e., respirators, facemasks, rubber gloves and aprons or coveralls, shall be provided for personnel handling chlorine chemical compounds and other caustic chemicals. Respirators approved by the National Institute for Occupational Safety and Health (NIOSH) shall be provided for protection against chlorine. At least one approved self-contained breathing apparatus shall be provided. Respiratory equipment shall be mounted outside the chlorine enclosure. Training and maintenance programs for respirators shall be provided in accordance with Occupational Safety and Health Administration (OSHA) requirements. (d) Filters. The recirculation system shall be equipped with a filtration system that will filter the entire contents of the pool at the required rate. Filtration equipment shall be operated continuously 24 hours per day. Design criteria for the indicated type of filters shall be as follows: (1) Rapid sand filter. A filter utilizing sand as the filter media, with filtration flow rate not exceeding three gallons per minute per square foot (122 liters per minute per square meter) of filter area. The backwash rate of flow shall be three times the filtration rate. (2) Anthracite filter. A filter utilizing anthracite as a filter media, with filtration flow rate not exceeding three gallons per minute per square foot (122 liters per minute per square meter) of filter area. The backwash rate of flow shall be three times the filtration rate. (3) High rate filter. A filter utilizing a media capable of filtration at a high rate of flow. The rate of flow shall be greater than five gallons per minute per square foot (203.7 liters per minute per square meter) of filter area. The backwash rate of flow shall be the same as filtration rate. (4) Diatomaceous earth filter. A filter utilizing diatomaceous earth as a filter media. There are two types of these filters: a. Pressure or vacuum-type. A diatomaceous earth filter through which the rate of flow does note exceed two gallons per minute per square foot (81.5 liter per minute per square meter). b. Pressure or vacuum-type with slurry feeder. A filter equipped to continuously feed a diatomaceous earth suspension and having a rate of flow not to exceed three gallons per minute per square foot (122 liters per minute per square meter). A backwash sump pit with a stand pipe shall be installed to collect spent diatomaceous earth so that it can be collected and disposed of with solid waste. Any other method for accomplishing this may be submitted for consideration. Other filtration systems which are equal to or better than those described above may be used in a pool recirculation system with the approval of the director of public health. (e) Gauges. Gauges shall be installed as required, on all filter systems to readily indicate the operating pressures of recirculating systems. All gauges shall measure pressure directly in pounds per square inch or kilograms per square meter and shall have an indicator at least two inches (5.08 centimeters) in diameter. (f) Rate of flow indicators. The recirculating system shall be equipped with a rate of flow indicator, which has been approved by the director of public health. The indicator shall read in gallons per minute or liters per minute and shall be located to indicate the rate of flow of filtered water being returned to the pool. The indicator shall be of fixed calibration and properly sized so as to indicate the designed rate of flow at approximately midscale. (g) Hair and lint strainer. At all installations where it is possible for water from the pool to pass through the filters, a strainer shall be provided on the suction side of the pump to prevent hair, lint and other matter from reaching the pump and filters. Strainers shall be corrosion-resistant with openings not over one-eighth-inch in size providing a free flow area at least four times the area of the pump suction line at the strainer connection and shall be accessible for frequent cleaning.
(Ord. No. 05-O-047, 4-26-05)
Ask a question about Chesapeake law
Corpus searches the Chesapeake sections it holds and shows the ones that match, with their citations. Free, no sign-in.