§ 14-188 — Operational safety
Code of the City of Chesapeake, Virginia (Supp. No. 148: codified through Ordinance No. 26-O-071, enacted August 11, 2026) · Chesapeake City Code § 14-188
Corpus is an independent public-information project, not the official City of Chesapeake website. Stable reference: corpuslaw.us/code/87988515-ae94-4b99-847b-130489615f06
Sec. 14-188. - Operational safety.
(a) Pumps, filters and other mechanical and electrical equipment for public pools and spas/hot tubs shall be enclosed in such a manner accessible only to authorized persons. Construction and drainage shall be such as to avoid the entrance and accumulation of water in the vicinity of the electrical equipment. (b) The crossing of outdoor public swimming pools and spas/hot tubs by overhead electrical conductors is prohibited. (c) All metal barriers or railings on which a broken electrical conductor might fall shall be effectively grounded. (d) All lighting fixtures shall be prohibited directly above the water surface, except as permitted by the Virginia Uniform Statewide Building Code, and shall be protected in a manner which will prevent broken glass from falling on any surface within the pool area. All electrical switches and receptacles shall be of weatherproof construction and resistant to corrosion. (e) Lights shall be prohibited directly above or within one meter horizontally of the pool or spa/hot tub rim in any indoor or covered swimming pool except as permitted in the Virginia Uniform Statewide Building Code.
(Ord. No. 05-O-047, 4-26-05)