Sec. 33.1-30. - Preliminary plan review—Submittal requirements; major and minor subdivisions.

The preliminary plan for a minor or major subdivision shall be on a blue-line or black-line print. If more than one sheet is used, sheets shall be numbered in sequence and an index shall be provided on the first sheet. The preliminary plan for a minor or major subdivision shall include the following information: (a) The name of the subdivision, owner, subdivider, and surveyor or engineer, the date of drawing, number of sheets, north arrow, graphic scale, legend for all symbols used, the names of all subdivisions immediately adjacent thereto, and the names of the owners of record of adjacent unsubdivided property. Meridian shown shall be based on City of Portsmouth geodetic control network. If shown on more than one sheet, match lines shall clearly indicate where the several sheets join. The preliminary plan shall also list any proffers or use permit conditions that affect the property. (b) The location of the proposed subdivision on an inset map at a scale of not less than one inch equals 1,000 feet, showing adjoining roads, their names and numbers, subdivisions and other landmarks. (c) A closed boundary survey, or existing survey of record, total acreage, acreage of subdivided area, existing buildings, existing graves, objects or structures marking a place of burial, names of owners and existing property lines within the boundaries of the tract and for adjacent properties thereto, proposed monuments, lots, lot numbers, lot areas, blocks, building setback and yard lines. The boundary survey shall conform to the requirements of Section 18VAC10-20-370 of the Code of Virginia. If any exceptions have been granted by the agent in accordance with section 33.1-23, the preliminary plan shall include a note detailing any exception so granted. In addition any use permit conditions, variances or proffers attached to the property shall also be noted. (d) All existing, platted and proposed streets, both private and public, including their names, numbers and widths; existing and proposed utility or other easements, culverts, drains, watercourses, lakes, their names and other pertinent data. If the streets are to be private, the plan shall include a private streets declaration in accordance with section 33.1-19. (e) Where the plan includes or abuts any natural or artificial body of water, show the approximate high waterline, bulkhead and pierhead lines where officially established, top of bank and toe of slope, proposed elevations and slopes for grading, and FEMA flood map and floodplain information. (f) Lot lines with dimensions and proposed setback lines; if a residential lot, the total number, type, and density per type of dwelling units to be placed thereon if more than one. (g) All parcels of land proposed to be dedicated or reserved for public use, and the conditions, if any, of such dedication. (h) A statement that appropriate erosion and sediment control methods shall be utilized prior to any clearing, grading or construction. (i) The preliminary plan for a major subdivision shall contain a copy of conceptual plan reviewed under the requirements of section 33.1-24. (j) Prior to application for final approval, the subdivider shall also submit to the city engineer and/or director of public utilities and secure approval of engineering development plans for those physical improvements set forth in sections 33.1-49 and 33.1-50 in accordance with the following: i. Such plans shall be prepared by a licensed professional engineer or land surveyor in the Commonwealth of Virginia and shall be complete, showing all essential details of the construction of the improvements at a scale generally acceptable to the city engineer. ii. The city engineer and/or the director of public utilities shall examine such plans and determine whether they meet the requirements of the zoning ordinance in chapter 40.2 and this chapter and whether they are in accord with sound engineering principles. The subdivider shall then be advised of their approval, disapproval or any change that might be necessary to merit approval. iii. Approval of the development plans by the city engineer or the director of public utilities does not constitute a guarantee of approval of the final plat. iv. Such plan shall show existing and proposed sidewalks. v. A drainage plan showing the proposed drainage system including all open ditches, closed storm drain pipes and stormwater management facilities proposed to convey the subdivision drainage to an adequate channel. The plan shall include sizes of all pipes and ditches, types of pipes and ditch linings, drainage easements and construction details of any stormwater management facilities. Drainage calculations shall be submitted with a drainage area map to verify the design of the drainage system including the adequacy of the channel receiving drainage from the proposed subdivision. vi. For multi-phased subdivisions, a drainage area map shall be provided with drainage calculations for all phases of the subdivision to determine the adequacy of receiving channels. If receiving channels are not adequate, the map shall include the location of proposed stormwater management facilities. vii. The drainage plan shall include the topographic plan and a soil map of the site. The topographic plan submittal requirements vary depending on the location of the proposed development. viii. An erosion control plan showing the location, type and details of proposed erosion and sediment control devices to be used during and after construction. The plan shall meet all requirements of the erosion and sediment control ordinance and shall be provided at a scale of 100 feet to the inch except in cases where the city engineer approves an alternate scale. The plan shall show existing and proposed contours at intervals of no more than five feet. ix. Cross-sections showing the proposed street construction, depth and type of base, type of surface, compaction, shoulders, curbs and gutters, sidewalks, bikeways, side ditches and other features of the proposed streets. x. Street profiles showing the proposed grades for the streets and drainage facilities, including elevations of existing and proposed ground surface at all street intersections and at points of major grade change along the centerline of streets, together with proposed connecting grade lines therewith. xi. Size and location of existing sanitary sewer and water facilities; location and method of proposed connections to existing sewer and water facilities; size and location of proposed sewer and water facilities showing location of proposed water meters, gate valves, fire hydrants, fittings, manholes, sewer laterals and cleanouts; grinder pump locations; profile views of water and sewer mains with manhole rim and invert elevations and percent of slope; sewage pump station location, design and details; and water well facility location, design and details.

(Ord. No. 2010-06, § 2, 1-26-2010; Ord. No. 2025-83, § 1(Exh. A), 10-28-2025)

Ask a question about Portsmouth law

Corpus searches the Portsmouth sections it holds and shows the ones that match, with their citations. Free, no sign-in.