For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 34-29 — Piping systems

Code of the City of Portsmouth, Virginia (Codified through Ordinance No. 2026-64, enacted June 23, 2026. (Supp. No. 66)) · Portsmouth City Code § 34-29

Corpus is an independent public-information project, not the official City of Portsmouth website. Stable reference: corpuslaw.us/code/a5262df7-c40a-42f5-b6bf-30c497747649

Sec. 34-29. - Piping systems.

(a) The piping system for public pools shall be composed of N.S.F. approved materials or equal, designed for the following operations: (1) Filling the pool; (2) Washing each filter to waste; (3) Recalculating the pool water through the treatment equipment; (4) Backwashing to waste; (5) Operating suction cleaner; (6) Emptying the pool; and (7) Draining the system. (b) There shall be no direct connections between the pool recirculating system and the sewer or the potable water supply. Fill spouts may be located under diving boards, under guard chairs or adjacent to pool ladder handrails. Fill spouts shall be installed a minimum of two inches (5.08 centimeters) above the coping, or submersed fill spouts shall be equipped with a backflow preventer. (c) Waste from backwashing shall be discharged into the sanitary sewer or in a manner approved by the administrative authority. (d) The piping system within the filter room shall be securely anchored and shall be color coded as follows: Freshwater—Blue (to check valve). Backwash—Black. Influent—Yellow. Effluent—White. Vacuum—Orange. (e) All piping shall be designed to reduce friction losses to a minimum and to carry the required quantity of water at a maximum velocity not to exceed ten feet per second (3.05 meters per second) for discharge piping, except for copper wire where the velocity for piping should not exceed eight feet per second (2.44 meters per second). Suction velocity for all piping should not exceed six feet per second (1.83 meters per second). Design system head calculations shall be required to confirm the adequacy of proposed pipe sizing and pump selection. (f) A permanent specification placard shall be conspicuously displayed on or adjacent to the filter and shall be properly lighted. Specifications, shall be printed or types and readily legible. The following information shall be included on the placard: (1) Name and location of facility; (2) Date of construction; (3) Capacity in gallons (liters); (4) Water surface area in square feet (square meters); (5) Turnover rate in hours; and (6) Rate of flow in gallons per minute (liters per minute).

(Code 1988, § 34-29; Ord. No. 1996-40, 6-25-1996)

Ask a question about Portsmouth law

Corpus searches the Portsmouth sections it holds and shows the ones that match, with their citations. Free, no sign-in.