Sec. 34-35. - Pool inlets.

Where inlets are in pool walls, such inlets shall be spaced not more than 19.7 feet (six meters) on center around the pool perimeter. Where inlets are in the pool bottom, the number of such inlets and location shall be so designed as to ensure the proper distribution of filtered water. All inlets, except freshwater inlets and wading pool inlets, shall be at least 15 inches (38.1 centimeters) below the overflow level of the pool except for prefabricated gutters with 45-degree angle inlets in the bottom. Each inlet shall be provided with a means of adjusting flow through a range of at least 50 percent of its design capacity. The control shall be readily accessible.

(Code 1988, § 34-35; Ord. No. 1996-40, 6-25-1996)