§ 38-166 — Purpose and definitions
Code of the City of Portsmouth, Virginia (Codified through Ordinance No. 2026-64, enacted June 23, 2026. (Supp. No. 66)) · Portsmouth City Code § 38-166
Corpus is an independent public-information project, not the official City of Portsmouth website. Stable reference: corpuslaw.us/code/9e262395-1600-4d9a-a6af-715c1b284479
Sec. 38-166. - Purpose and definitions.
(a) The purpose of this article shall be to establish a cross connection control and backflow prevention program as required by the Virginia Department of Health's Waterworks Regulations, article 3. (b) The following words, terms and phrases, when used in this article, shall have the meanings ascribed to them in this subsection, except where the context clearly indicates a different meaning: Air gap means the unobstructed distance through a free atmosphere between the lowest perimeter of a water outlet and the flood-level rim of any receptacle. This distance shall be minimum of two times the diameter of the outlet. (In case of near-walls, this distance shall be three times the diameter of the outlet.) Approved means the term as herein used in reference to air-gap separation, a double check valve assembly, a reduced pressure principle backflow prevention assembly or other backflow prevention devices or methods shall mean an approval by the director. Auxiliary supply means any water source or system other than the public water supply that may be available. Backflow means the reversal of flow from its intended direction as a result of backsiphonage or backpressure. Backflow prevention means an approved assembly or device that prohibits the backflow of water. Backpressure means a pressure, higher than supply pressure, caused by a pump, elevated tank, boiler, air/stream pressure, or any other means, which may cause backflow. Backsiphonage means a type of backflow caused by a negative or reduced pressure in the supply piping. Contamination means any introduction into potable water of chemicals that are not part of the water treatment process, gases, microorganisms, wastes or wastewater. Cross connection means any connection or structural arrangement, direct or indirect, to the waterworks whereby backflow can occur. Director means the director of the department of public utilities or the director's designee. Division means the Commonwealth of Virginia, Department of Health, Division of Water Supply Engineering. Double-gate/double-check valve assembly means an approved assembly of two internally spring-loaded, specially designed and independently operating check valves, together with a tightly closing resilient seating shutoff valve on the upstream and the downstream side of the check valves, equipped with four properly placed female-threaded test cocks. Existing ground level means the level above which surface water will not accumulate under normal conditions. Flood-level rim means the top edge of the receptacle over which water could overflow. Hazard means any condition, device or practice in the water usage system and its operation which creates or reasonably tends to create a danger to the health and well-being of the water consumer. Owner means the person having legal title to the property or who is in charge, care and control of the property where the facilities in question are located; also, the tenant of such property; also, the customer who signed the water service agreement for such property. Pollution means the presence of any foreign substance (chemical, physical, radiological or biological) in water that tends to degrade its quality so as to constitute an unnecessary risk or impair the usefulness of the water. Reduced pressure principle backflow preventer means an approved assembly of two independently operating spring-loaded check valves with a pressure differential relief valve and tightly closing resilient seating shutoff valves on the upstream and the downstream side of the assembly with four properly placed female-threaded test cocks. Service connection means the terminal end of a service line from the waterworks. If a meter is installed at the end of the service, then the service connection means the downstream end of the meter. Service line means that portion of the water line from the consumer's side of the water meter to the first water outlet. Toxin means any substance of solids, or liquids or gases harmful for human consumption. Vacuum breaker, atmospheric, means a device that consists of a float check, a check seat and an air inlet port. This unit may never be subjected to a backpressure condition or have a downstream shutoff valve, or be installed where it will be in continuous operation for more than 12 hours. Vacuum breaker, pressure type, means an assembly consisting of an independently operating internally loaded check valve, an independently operating loaded air inlet valve located on the discharge side of the check valve, with two properly located test cocks and tightly closing resilient seated shutoff valves.
(Code 1973, § 38-67.2; Code 1988, § 38-166; Ord. No. 1990-111, § 1, 10-9-1990; Ord. No. 1992-3, § 1, 1-14-1992; Ord. No. 1994-3, § 1, 1-11-1994)
Ask a question about Portsmouth law
Corpus searches the Portsmouth sections it holds and shows the ones that match, with their citations. Free, no sign-in.