Section 2102. - Urban Center 2 (UC 2) District & Neighborhoods
2102.A Purpose. The Urban Center 2 District includes the existing high-density developments along Barre Street. The area is served by sewer and water and is located on major public transit routes. The purpose of this district is to maintain a compact walkable urban center by preserving the historic pattern of development. 2102.B Neighborhood Character. The Urban Center 2 District includes the following neighborhoods: (1) Barre Street - West. This neighborhood encompasses the blocks along Barre Street immediately adjacent to the downtown business district. Once largely residential, many of the historic homes in this neighborhood have been converted into mixed-use or multi-unit buildings. The development pattern is primarily characterized by large, multi-story residential-style buildings on small parcels with narrow front and side setbacks. Proposed development should feature a mix of uses either within historic buildings or within new construction that is compatible in scale and character to neighboring historic buildings. This neighborhood is well suited for infill with higher-density, multi-unit housing, particularly on sites that are currently developed at a lower density than allowed in this zoning district and with buildings that are not contributing historic structures. 2102.C Use Standards. Figure 2-15 lists the uses that are permitted or conditional in the Urban Center 2 district. Drive-through facilities and drive-in establishments are prohibited except as specifically authorized in Figure 2-15. 2102.D Dimensional Standards. Figure 2-02 establishes the dimensional standards for development in the Urban Center 2 district. Dimensional standards are discussed further in Section 3002. 2102.E Architectural Standards. The following standards apply for major site plan applications (see Section 3201) under Section 3207: (1) Buildings with 3 or more stories shall incorporate a base, middle and cap as described below: (a) The base shall include an entryway with transparent windows and a molding or reveal placed between the first and second story or over the second story, which shall be at least 2 inches deep and 4 inches high. (b) The middle may include windows and balconies. (c) The cap shall include the area from the top floor to the roof of the building, and shall include a cornice or roof overhang. (2) Floor levels, windowsills, moldings, and cornices shall align with those of adjacent buildings to the maximum extent feasible. (3) Building facades shall be composed of modules or bays that: (a) Incorporate visible changes in the facade elevation through the use of wall plane projections or recesses, piers, columns, colonnades, arcades or similar architectural features that create a distinct facade elevation. (b) Feature a regular pattern of windows and entryways so that the length of solid or blank walls shall not exceed 20 feet. (c) Shall not exceed 48 feet in width and an average of 32 feet in width for a single, continuous facade. (4) Building facades shall incorporate at least one principal entrance as follows: (a) Building facades exceeding 60 feet in width shall provide multiple ground-level entrances. (b) The distance between ground-level entrances along a single, continuous facade shall not exceed 80 feet. (5) Pedestrian access shall be provided from the public sidewalk or street to the street-facing principal entrance(s). (6) The street-facing principal entrance(s) and ground floor level shall align with the sidewalk elevation to the maximum extent feasible. (7) Mechanical equipment, electrical meter and service components, and similar utility devices whether at ground level or mounted on the building shall be screened from view at the street with materials that are compatible with the building's predominant exterior materials. 2102.F Riverfront Standards. To promote redevelopment of the riverfront as an amenity and greenway corridor, development within the water setback area: (1) Shall meet the groundcover requirements of Section 3005.F but no riparian buffer is required. (2) Are encouraged to provide public walkways, multi-use pathways, outdoor seating, and similar public amenities along the river. An applicant may request a waiver to water setback requirements for such amenities within the water setback upon demonstrating that the proposed design furthers the city's riverfront redevelopment goals. Figure 2-02. Urban Center 2 Dimensional Standards PARCELS | SETBACKS | DENSITY | BUILDINGS Parcel size: 6,000 sf min Frontage: 60 ft. min Coverage: 90% max | Front: 5 ft. min Side: 5 ft. min Rear: 10 ft. min Water: 20 ft. min | Floor Area Ratio: 3.0 max | Height: 24 ft. min, 55 ft. max Note 1: See Section 3002 for specific information and any exceptions regarding dimensional standards. Accessory structures may have reduced dimensional standards (see Section 3003 for specific details regarding accessory structures).
Ask a question about Montpelier law
Corpus searches the Montpelier sections it holds and shows the ones that match, with their citations. Free, no sign-in.