§ 2112 — Urban Residential (UR) District & Neighborhoods
Code of Ordinances of the City of Montpelier, Vermont (Codified through Ordinace No. 2026-0413, adopted April 8, 2026. (Supp. No. 2, Update 1)) · Montpelier Code of Ordinances § 2112
Corpus is an independent public-information project, not the official City of Montpelier website. Stable reference: corpuslaw.us/code/fd228ada-26f1-436c-8276-1120916fb940
Section 2112. - Urban Residential (UR) District & Neighborhoods
2112.A Purpose. The Urban Residential District encompasses areas that are planned for dense urban development which tend to be more residential in form and use. These areas are either currently served by sewer and water or will be at the time of development. All Urban Residential areas should create new compact walkable urban areas and be well integrated into transportation networks including new and existing shared use paths as well as public transit routes. These new high-density residential areas should include significant public recreational opportunities to allow a range of opportunities within a short walk of their homes. These areas are not intended for exclusive residential development and appropriate complementary uses (e.g. day cares, medical clinics, coffee shops, etc.) should be allowed and encouraged. 2112.B Neighborhood Character. The Urban Residential District includes the following neighborhoods: (1) Country Club—Urban. This new development area includes approximately 17 acres of the lower former country club where the City's Actionable Plan for the Country Club Road Site proposes high density housing and a future community center. The desire is for this area to allow residential buildings up to 5 or 6 stories and to have rules that are flexible in how it is designed and laid out. Proposed development should promote a pedestrian-oriented design that balances the future recreation and community uses along with the residential and some limited commercial uses. 2112.C Use Standards. Figure 2-15 lists the uses that are permitted or conditional in the Urban Residential district. Drive-through facilities and drive-in establishments are prohibited except as specifically authorized in Figure 2-15. 2112.D Dimensional Standards. Figure 2-12 establishes the dimensional standards for development in the Urban Residential district. Dimensional standards are discussed further in Section 3002. 2112.E Architectural Standards. The following standards apply for major site plan applications (see Section 3201) under Section 3207: (1) Buildings with 3 or more stories shall incorporate a base, middle and cap as described below: (a) The base shall include an entryway with transparent windows and a molding or reveal placed between the first and second story or over the second story, which shall be at least 2 inches deep and 4 inches high. (b) The middle may include windows and balconies. (c) The cap shall include the area from the top floor to the roof of the building, and shall include a cornice or roof overhang. (2) Floor levels, windowsills, moldings, and cornices shall align with those of adjacent buildings to the maximum extent feasible. (3) Building facades shall be composed of modules or bays that: (a) Incorporate visible changes in the facade elevation through the use of wall plane projections or recesses, piers, columns, colonnades, arcades or similar architectural features that create a distinct facade elevation. (b) Feature a regular pattern of windows and entryways so that the length of solid or blank walls shall not exceed 20 feet. (c) Shall not exceed 48 feet in width and an average of 32 feet in width for a single, continuous facade. (4) Building facades shall incorporate at least one principal entrance as follows: (a) Building facades exceeding 60 feet in width shall provide multiple ground-level entrances. (b) The distance between ground-level entrances along a single, continuous facade shall not exceed 80 feet. (5) Pedestrian access shall be provided from the public sidewalk or street to the street-facing principal entrance(s). (6) The street-facing principal entrance(s) and ground floor level shall align with the sidewalk elevation to the maximum extent feasible. (7) Mechanical equipment, electrical meter and service components, and similar utility devices whether at ground level or mounted on the building shall be screened from view at the street with materials that are compatible with the building's predominant exterior materials. Figure 2-12. Urban Residential Dimensional Standards PARCELS | SETBACKS | DENSITY | BUILDINGS Parcel size: 9,000 sf min Frontage: 60 ft. min Coverage: 80% max | Front: 10 ft. min Side: 10 ft. min Rear: 10 ft. min Water: 25 ft. min | Floor Area Ratio: 4.0 max for residential; 1.0 max for other | Height: 24 ft. min, 60 ft. max Note 1: See Section 3002 for specific information and any exceptions regarding dimensional standards. Accessory structures may have reduced dimensional standards (see Section 3003 for specific details regarding accessory structures).
Ask a question about Montpelier law
Corpus searches the Montpelier sections it holds and shows the ones that match, with their citations. Free, no sign-in.
