§ 7.02.380 — Approved backflow preventers required
Kent City Code (current through Ordinance 4547, passed August 18, 2026) · Kent City Code § 7.02.380
Corpus is an independent public-information project, not the official City of Kent website. Stable reference: corpuslaw.us/code/148f5282-837c-41a9-a37a-44d7512ae1a2
7.02.380 Approved backflow preventers required.
A. Approved backflow preventers shall be installed at the city’s water service connection commensurate with the assessed degree of hazard. The consumer shall install and maintain all approved backflow preventers deemed necessary by the standards established by the city. B. Premises isolation is required for the following service connections: 1. Severe and high health cross-connection hazard premises listed in WAC 246-290-490(4)(b), Table 9; 2. New commercial multi-tenant facilities; 3. Single-family dwellings with access to an auxiliary water supply; 4. Commercial fire lines; 5. Commercial irrigation systems; 6. Residential irrigation systems (per the UPC); 7. Residential fire sprinkler systems, excluding the flow-through type (per the UPC). C. Premises isolation may be required after an assessment by the public works department of the following service connections: 1. New commercial facilities; 2. Commercial facilities after a substantial alteration; 3. Facilities with complex plumbing arrangements that make it impracticable to assess whether cross-connection hazards exist; 4. Facilities with cross-connection hazards that are unavoidable or not correctable, such as, but not limited to, facilities which are more than two stories. D. Commercial fire lines with single check valve backflow preventers are subject to the following requirements: 1. Where an existing fire line and/or private fire hydrant system is altered or extended, the existing fire line, fire hydrant(s) and/or yard hydrant and all related backflow protection assemblies shall be upgraded to comply with current city codes. The upgrade requires a backflow permit and all upgrades shall be completed prior to final inspection and permit approval. 2. When single check valve backflow preventers are discovered, the public works department will issue a notice requiring replacement with an approved backflow prevention assembly. The replacement shall be completed within one year of the notice or other timeframe acceptable to the public works department.
(Ord. No. 4288, § 2, 11-20-18)
Ask a question about Kent law
Corpus searches the Kent sections it holds and shows the ones that match, with their citations. Free, no sign-in.