§ 13.06.100 — Building design standards
Municipal Code, City of Tacoma, Washington (Tacoma Municipal Code current through legislation adopted 2026-09-30 (eCode360 publication TA6977, scraped 2026-11-18)) · Tacoma Municipal Code § 13.06.100
Corpus is an independent public-information project, not the official City of Tacoma website. Stable reference: corpuslaw.us/code/303a0021-b835-4166-a518-07796643a707
§ 13.06.100: Building design standards.
A. Commercial District minimum design standards. 1. General applicability. The design standards of this section are required to implement the urban design goals of the Comprehensive Plan of the City of Tacoma. The building design standards apply to all new development as outlined below, except as follows: a. Standards. Each item of this section shall be addressed individually. Exceptions and exemptions noted for specific development situations apply only to the item noted. b. Alterations. (1) Three thresholds are used to gauge the extent of design standard compliance on alterations to existing development: Level I alterations include all remodels and/or additions within a two year period whose cumulative value is less than 50% of the value of existing development or structures, as determined by the applicable Building Code. The requirement for such alterations is only that the proposed improvements meet the standards and do not lead to further nonconformance with the standards. For example, if a property owner decides to replace a building façade’s siding, then the siding shall meet the applicable exterior building material standards, but elements such as building modulation would not be required. Level II alterations include all remodels and/or additions within a two year period whose cumulative value ranges from 50% to 200% of the value of the existing development or structure, as determined by the applicable Building Code. All standards that do not involve repositioning the building or reconfiguring site development shall apply to Level II alterations. Level III alterations include all remodels and/or additions within a two year period whose cumulative value exceeds 200% of the value of the existing development or structure, as determined by the applicable Building Code. Such alterations shall conform to ALL standards. (2) The standards do not apply to remodels that do not change the exterior form of the building. However, if a project involves both exterior and interior improvements, then the project valuation shall include both exterior and interior improvements. (3) No addition or remodel shall increase the level of nonconformity or create new nonconformities to the development or design standards. c. Super regional malls. Additions to super regional malls of less than 10,000 square feet of floor area are exempt from the design standards of this section. d. Temporary. Temporary structures are exempt from the design standards of this section. e. Residential and/or mixed-use (outside of Urban Residential Districts). (1) Single, two, and three-unit dwellings are subject only to the design standards in Subsection E. Townhouses are subject only to the design standards in Subsection G. For other residential uses, such as mixed-use buildings and multi-unit dwellings of 4 units or more, the standards herein apply unless otherwise noted. (2) Multi-unit residential development with a commercial component located within the C1, C2, T, and PDB zoning districts, and within the Neighborhood Commercial Future Land Use Map (FLUM) (as defined in Figure 2 of the Urban Form chapter of the Comprehensive Plan) are subject to the requirements in Section 13.06.100B Mixed-Use District Minimum Design Standards. (3) Single-unit dwellings legally established prior to August 1, 2011 are exempt from these standards. However, remodels and additions to such single-unit dwellings shall not increase the level of nonconformity. f. Historic. In any conflict between these standards and those applied by the Tacoma Landmarks Preservation Commission, the standards of the commission shall prevail. g. Religious assembly facilities which can demonstrate that the design standards impose a substantial burden, administratively or financially, on their free exercise of religion, shall be exempt from compliance. h. Floor area. For purposes of this section of the code (Section 13.06.100), “floor area” shall not include spaces below grade. i. Parks, recreation and open space uses. Accessory or ancillary structures, such as restroom buildings, playground equipment and picnic shelters, are exempt from the design standards of this section. j. Accessory structure. Shipping containers are exempt from all sections except Subsection 9 below. 2. Zoning district applicability. The following requirements apply to the C1, C2, T, and PDB zoning districts. See Section 13.06.100B, for X-District requirements. Single-use multi-unit residential developments in the C1, C2, T, and PDB zoning districts are subject to the requirements in Section 13.06.100C Multi-unit Residential Minimum Design Standards. 3. Mass reduction standards. Purpose: The following design choices are intended to help reduce the apparent mass of structures and achieve a more human scale environment by providing physical breaks in the building volume that reduce large, flat, geometrical planes on any given building elevation. a. Size to choice ratio for b below (1) Buildings under 7,000 square feet of floor area are not required to provide mass reduction. (2) Buildings from 7,000 square feet of floor area to 30,000 square feet of floor area shall provide at least one mass reduction feature. (3) Buildings over 30,000 square feet of floor area shall provide at least two mass reduction features. b. Mass reduction choices (1) Upper story. Buildings with a maximum footprint of 7,000 square feet of floor area, that do not exceed 14,000 square feet of floor area, may count use of a second story as a mass reduction feature. (2) Upper story setback. An 8 feet minimum setback for stories above the second story for elevations facing the street or parking lots over 20 stalls. This requirement applies to a maximum of 2 elevations. (3) Wall modulation. Maximum 100 feet of wall without modulation, then a minimum 2 feet deep and 15 feet wide offset of the wall and foundation line on each elevation facing the street, parking lots over 20 stalls, or residential uses. (4) Public plaza. A public plaza of at least 800 square feet or 5 percent of building floor area, whichever is greater. The plaza shall be located within 50 feet of and visible to the primary public entrance; and contain a minimum of a bench or other seating, tree, planter, fountain, kiosk, bike rack, or art work for each 200 square feet of plaza area. Any proposed art work shall be coordinated with the City’s Arts Administrator and/or approved by the Arts Commission, as determined by the Arts Administrator. Plaza contents may count toward other requirements when meeting the required criteria. Walkways do not count as plazas. Plazas shall not be used for storage. Required parking stalls may be omitted to the minimum necessary if needed to provide the plaza. Where public seating is provided, it shall utilize designs that discourage long-term loitering or sleeping, such as dividers or individual seating furniture. Plazas may be permeable pavement or pavers where feasible. Low Impact Development vegetated stormwater features may be used for up to 30% of the plaza requirement where feasible. [image] Figure: Upper Story Setback | [image] Figure: Wall Modulation Example [image] Figure: Public Plaza Example 4. Roofline standards. Purpose: The following standards are intended to ensure that roofline is addressed as an integral part of building design to avoid flat, unadorned rooflines that can result in an industrial appearing, monotonous skyline. Roofline features are also intended to further reduce apparent building volume and further enhance features associated with residential and human scale development. All buildings with rooflines of 100 feet or more in length, except where otherwise noted, must use one or more of the following roofline choices. a. Roofline choices. (1) Sloped roof. Use of a roof form with a pitch no flatter than 5/12. Rounded, gambrel, and/or mansard forms may be averaged. (2) Modulated roof. Use of features, which are a minimum of 2 feet in height, such as a terracing parapet, multiple peaks, jogged ridge lines, dormers, etc., with a maximum of 100 feet uninterrupted roofline between roof modulation elements. Modulation elements shall equal a minimum of at least 15 percent of the roofline on each elevation. The maximum shall be 50 feet of uninterrupted roofline along the eave between roof modulation elements in C 1 Districts and on sides facing residential uses or districts. Roof forms with a pitch flatter than 5/12 are permitted with this option; provided, the appropriate modulation is incorporated. (3) Corniced roof*. A cornice of two parts with the top projecting at least 6 inches from the face of the building and at least 2 inches further from the face of the building than the bottom part of the cornice. The height of the cornice shall be at least 12 inches high for buildings 10 feet or less in height; 18 inches for buildings greater than 10 feet and less than 30 feet in height; and 24 inches for buildings 30 feet and greater in height. Cornices shall not project over property lines, except where permitted on property lines abutting public right-of-way. (4) Canopy exemption. Fueling station canopies, drive-through canopies, or similar canopies are exempt from roofline requirements. Figure: Roofline Examples [image] Figure: Modulated Roof Example [image] Figure: Cornice Example [image] 5. Windows and openings. Purpose: The following standards are intended to increase public visibility for public safety, to provide visual interest to pedestrians that helps encourage pedestrian mobility, and to provide architectural detailing and variety to building elevations on each story. a. Street level. (1) Front, side, or corner side exterior walls facing streets or that contain customer entrances and face customer parking lots of 20 stalls or greater shall have transparent window or openings for at least 50 percent of the ground level wall area. This standard shall apply on a maximum of 2 such building elevations. The window and opening requirements shall be reduced to 30 percent of the ground level wall area for portions of façades where the grade level of the sidewalk of the abutting street is 4 feet or more above or below the adjacent floor level of the building. The requirement shall be further reduced to 20 percent of the ground level wall area in instances where the application of this standard is not possible due to steep grades and the correlating location of the floor plates of the building. Rough openings are used to calculate this requirement. (2) Required view. Required windows or openings must provide either views into building work areas, sales areas, lobbies, merchandise displays, or artworks. Review of any proposed public art shall be coordinated with the City’s Arts Administrator and/or approved by the Arts Commission, as determined by the Arts Administrator. Art and display windows shall be at least 2 feet deep, recessed and integrated into the façade of the building (tack on display cases do not qualify). (3) The “ground level wall area” is defined as the area between 2 feet and 8 feet above the adjacent finished grade. (4) Limited alternatives. Alternatives of decorative grilles, art work, or similar features can be substituted for those portions of uses where the provision of natural light can be demonstrated to nullify the intended use (examples include movie theater viewing areas and light sensitive laboratories) and for parking structures, provided an equivalent wall area is covered. Review of any proposed public art shall be coordinated with the City’s Arts Administrator and/or approved by the Arts Commission, as determined by the Arts Administrator. b. Upper levels. (1) Front, side, or corner side exterior walls facing streets or walls that contain customer entrances and face customer parking lots of 20 stalls or greater shall use a combination of transparent windows or openings and architectural relief that provide visual demarcation of each floor on a minimum of 2 such building elevations. (2) Upper level windows shall be a different type than the ground level windows on the same elevation. (3) For purposes of this requirement, a window type is either a grouping of windows, a window size, or a window shape. c. Exemptions. (1) Residential privacy. On sides where C, T, or PDB District boundaries adjoin UR-1, UR-2, or UR-3 District boundaries, structures within the C, T, or PDB District that are set back at least 7 feet from the property line and screened by landscaping to a minimum height of 6 feet are exempt from the window and opening requirements on the effected side. Figure: Development requirements for facades windows/openings [image] 6. Façade surface standards. Purpose: The following standards are intended to help reduce the apparent mass of structures and achieve a more human scale environment by providing visual breaks at more frequent intervals to the building volume that reduce large, flat, geometrical planes on any given building elevation, especially at the first story. The choices are also intended to encourage variety in the selection of façade materials and/or treatment and to encourage more active consideration of the surrounding setting. a. Blank walls. (1) Applicability. A blank wall on the first story that is more than 25 feet in length and faces a public street and/or highway right-of-way, residential zone, or customer parking lot is subject to these requirements. (2) Requirements. These blank wall areas must employ at least one of the following treatments to create a visual break between blank wall segments. The visual break treatment must be at least one foot in width and employed at least every 25 feet. Stored or displayed merchandise, pipes, conduit, utility boxes, air vents, and/or similar equipment do not count toward this requirement. • Building modulation; • Windows; • Openings; • Landscaping; • Architectural relief, such as visibly different textured material. b. Façade variety. (1) Buildings with under 2,000 square feet of floor area are exempt from the variety requirement. (2) Buildings with 2,000 square feet of floor area to 30,000 square feet of floor area shall use at least 2 different materials, textures, or patterns on each building elevation. (3) Buildings with over 30,000 square feet of floor area shall use at least 3 different materials, textures, or patterns on each building elevation. (4) For purposes of this requirement, each material, texture, or pattern must cover a minimum of 10 percent of each building elevation. Glass does not count toward this requirement. Different texture or pattern shall be visibly different from adjacent public right-of-way or parking area. c. Building face orientation. (1) The building elevation(s) facing street or highway public rights-of-way shall be a front, side, or corner side and shall not contain elements commonly associated with a rear elevation appearance, such as loading docks, utility meters, and/or dumpsters. (2) This requirement applies to a maximum of 2 building elevations on any given building. 7. Pedestrian standards. Purpose: The following standards are intended to enhance pedestrian mobility and safety in commercial areas by providing increased circulation, decreasing walking distances required to enter large developments, and providing walkways partially shielded from rain and/or snow. a. Customer entrances. (1) Additional entrances. An additional direct customer entrance(s) shall be provided to the same building elevation which contains the primary customer entrance so that customer entrances are no further than 250 feet apart when such elevations face the public street or customer parking lot. If a corner entrance is used, this requirement applies to only 1 elevation. (2) Designated streets. Non residential or mixed-use buildings on designated pedestrian streets noted in Section 13.06.030 or Section 13.06.300C shall provide at least 1 direct customer entrance, which may be a corner entrance, within 20 feet, facing, and visible to the designated street. For such buildings over 30,000 square feet of floor area, the maximum distance is increased to 60 feet. b. Residential entrances. (1) Buildings meeting the “build-to area” for designated pedestrian streets shall provide at least 1 entrance within 8 feet of the longest street facing wall of the building. Buildings that have a shared main entrance must use the shared main entrance to fulfill the requirements of this standard. (a) The shared main entrance must face the street or be at an angle of up to 45 degrees from the street. (b) The shared main entrance may open onto a porch. The porch must have a minimum dimension of 4 feet by 6 feet; have a roof that is no more than 12 feet above the floor of the porch; and be at least 30 percent solid. If at least 30 percent of the porch is covered with a solid roof, the rest may be covered with an open material, such as a trellis. (2) Weather protection is required for all multi-unit building entries. For private entries, required weather protection must be at least 3 feet deep along the width of the entry. For common building entries, the required weather protection shall be 5 feet. c. Street level weather protection. (1) Weather protection shall be provided above a minimum of 25 percent of the length of hard surfaced, public or private walkways and/or plazas along façades containing customer and/or public building entries or facing public street frontage. (2) Weather protection may be composed of awnings, canopies, arcades, overhangs, marquees, or similar architectural features. It is required to cover only hard surfaced areas intended for pedestrian use and not areas such as landscaping. (3) Weather protection must cover at least 5 feet of the width of the public or private sidewalk and/or walkway, but may be indented as necessary to accommodate street trees, street lights, bay windows, or similar building accessories to not less than 3 feet in width. 8. Rooftop utility screening. Purpose: These requirements are intended to minimize visibility of utilities, mechanical equipment, and service areas to mitigate visual impact on residential privacy, public views, and general community aesthetics. All rooftop mechanical equipment for new construction shall be screened with an architectural element such as a high parapet, a stepped or sloped roof form or an equivalent architectural feature which is at least as high as the equipment being screened. Fencing is not acceptable. The intent of the screening is to make the rooftop equipment minimally visible from public rights-of-way within 125 feet of the building, provided said rights-of-way are below the roof level of the building. In those instances where the rights-of-way within 125 feet of the building are above the roof level of the building, the mechanical equipment should be the same color as the roof to make the equipment less visible. Limited flexibility in this standard is allowed to ensure that the function of the HVAC equipment is not compromised by the screening requirement. Figure: Utility Storage [image] 9. Accessory structure – Shipping container. a. Shipping Containers are allowed as an accessory structure in all Commercial Districts subject to the standards set forth below: (1) Shipping containers shall not be located between the building and street right-of-way. On corner lots, this applies to front and side. (2) Shipping container must be setback a minimum of 5 feet from all property lines; and (3) When the shipping container is not between the building and street right-of-way, it must be setback further from right-of-way than the wall of building and a minimum of 5 feet, whichever is greater. On corner lots, this applies to front and side. (4) Shipping containers shall be screened from any Residential District when adjacent to or across an alley from the Residential District. In this case it must be screened by a minimum 6-foot tall solid wood fence and/or landscaping. (5) Each site is limited to one shipping container. (6) Shipping containers may not be placed within a shopping center as defined in TMC § 13.01.060S. (7) See TMC § 13.06.080P for regulations specific to shipping containers as a temporary use. B. Mixed-Use District minimum design standards. 1. General applicability. The design standards of this section are required to implement the urban design goals of the Comprehensive Plan of the City of Tacoma. The building design standards apply to all new development as outlined below, except as follows: a. Standards. Each item of this section shall be addressed individually. Exceptions and exemptions noted for specific development situations apply only to the item noted. b. Alterations. (1) Three thresholds are used to gauge the extent of design standard compliance on alterations to existing development: Level I alterations include all remodels and/or additions within a two year period whose cumulative value is less than 50% of the value of existing development or structures, as determined by the applicable Building Code. The requirement for such alterations is only that the proposed improvements meet the standards and do not lead to further nonconformance with the standards. For example, if a property owner decides to replace a building façade’s siding, then the siding shall meet the applicable exterior building material standards, but elements such as building modulation would not be required. Level II alterations include all remodels and/or additions within a two year period whose cumulative value ranges from 50% to 200% of the value of the existing development or structure, as determined by the applicable Building Code. All standards that do not involve repositioning the building or reconfiguring site development shall apply to Level II alterations. Level III alterations include all remodels and/or additions within a two year period whose cumulative value exceeds 200% of the value of the existing development or structure, as determined by the applicable Building Code. Such alterations shall conform to ALL standards. (2) The standards do not apply to remodels that do not change the exterior form of the building. However, if a project involves both exterior and interior improvements, then the project valuation shall include both exterior and interior improvements. (3) No addition or remodel shall increase the level of nonconformity or create new nonconformities to the development or design standards. c. Super regional malls. Additions to super regional malls of less than 10,000 square feet of floor area are exempt from the design standards of this section. d. Temporary. Temporary structures are exempt from the design standards of this section. e. Residential and/or mixed-use. (1) Single, two, and three-unit dwellings are subject only to the design standards in Subsection E. Townhouses are subject only to the design standards in Subsection H. For other residential uses, such as mixed-use buildings and multi-unit dwellings of 4 units or more, the standards herein apply unless otherwise noted. (2) Single-unit dwellings legally established prior to August 1, 2011 are exempt from these standards. However, remodels and additions to such single-unit dwellings shall not increase the level of nonconformity. f. Historic. In any conflict between these standards and those applied by the Tacoma Landmarks Preservation Commission, the standards of the commission shall prevail. g. Religious assembly facilities which can demonstrate that the design standards impose a substantial burden, administratively or financially, on their free exercise of religion, shall be exempt from compliance. h. Floor area. For purposes of this section of the code (Section 13.06.090C), “floor area” shall not include spaces below grade. i. Parks, recreation and open space uses. Accessory or ancillary structures, such as restroom buildings, playground equipment and picnic shelters, are exempt from the design standards of this section. 2. Zoning District applicability. The following requirements apply to all development located in any X-District, and to multi-unit residential development with a commercial component located within the C1, C2, T, and PDB zoning districts and within the Neighborhood Commercial FLUM (as defined in Figure 2 of the Urban Form chapter of the Comprehensive Plan), except where noted or unless specifically exempted. 3. Ground level design. a. Façade details & articulation. Applicability: All building façades fronting a designated Pedestrian Street must include the following required and selected articulation features at intervals no greater than 40 feet. Buildings that have 60 feet or less of frontage on the designated pedestrian street are exempt from this standard. (1) Required features. Use of vertical piers (minimum 2 inch projection) and arrangement of windows and/or entries that reinforce the pattern of small storefront spaces. (2) Optional features. Choose one from each of the following categories: (a) Window and/or entry treatment: • | Display windows divided into a grid of multiple panes. • | Transom windows. • | Roll-up windows/doors. • | Recessed entry. • | Decorative door. • | Arcade. • | Landscaped trellises or other permanent decorative elements that incorporate landscaping near the building entry. (b) Building materials and other façade elements: • | Decorative weather protection element(s) such as a steel canopy or glass, fixed-fabric, or retractable awning. • | Decorative building-mounted light fixtures. • | Use of brick, stonework, and architectural pre-cast concrete for at least 10 percent of siding material on the façade. • | Incorporating a decorative mix of building materials. • | Decorative kick-plate, pier, or belt course. Example FiguresThese figures all depict acceptable façade articulation examples. All use window configurations to reinforce the desired small storefront pattern. This building uses roofline modulation, window configurations, and weather protection elements to reinforce the pattern of small storefronts. [image] This building employs a regular pattern of vertical piers. [image] This building incorporates different weather protection elements. [image] b. Weather protection. (1) General requirements. (a) Weather projection may be composed of awnings, canopies, arcades, overhangs, marquees, or similar architectural features. (b) Weather protection must cover at least 5 feet in width of the public or semi-public sidewalk but reduced to accommodate trees, lighting, bay windows, or similar building features to not less than 3 feet in width. (2) Minimum requirements. (a) Pedestrian Street-facing building facades. Weather protection shall be provided above all entrances and along a minimum of 80 percent of ground level building facades abutting or located within 5 feet of a hard-surfaced public or private sidewalk, walkway, and/or amenity space. (b) Building facades facing a non-Pedestrian Street or common amenity space. Weather protection shall be provided above all entrances and along a minimum of 50 percent of ground level building facades abutting or located within 5 feet of a hard-surfaced public or private sidewalk, walkway, and/or amenity space. c. Building orientation & entrances. (1) Residential buildings/uses. (a) Location. Primary entrances must be oriented to the abutting street and must include features that visually communicate its prominence and function such as signage, weather protection, wayfinding, pedestrian lighting, landscaping, walls/fences, etc. If the building has more than one street frontage where one is a designated Pedestrian Street, the primary entrance must be oriented to the Pedestrian Street except that the primary entrance for residential units within a mixed-use building may be located on non-Pedestrian Street so long as Primary Entrance for the non-residential uses are provided along the Pedestrian Street. If no entrance clearly meets the definition of a Primary Entrance, at least one entrance must be designated and designed as such according to these standards. (b) Dimensions. Each Primary Entrance must include a covered space that is at least four feet wide and six feet deep except for developments that only include individual, ground-related unit entrances (see below). For shared entrances that are not a Primary Entrance, the required covered space must be at least four feet wide and five feet deep. For entries to individual ground-related units, the covered space must be at least four feet wide and three feet deep. This space may either be recessed or projecting from the front building wall and may encroach into the right-of-way. The weather protection cover may not be more than 12 feet above grade. (2) Non-residential buildings/uses. (a) Location. A publicly-accessible Primary Entrance must be oriented to the abutting street, located within 20 feet of the street, and must include features that visually communicate its prominence and function such as signage, weather protection, wayfinding, pedestrian lighting, landscaping, walls/fences, etc. If the building has more than one street frontage where one is a designated Pedestrian Street, the primary entrance must be oriented to the Pedestrian Street. If no entrance clearly meets the definition of a Primary entrance, at least one entrance must be designated and designed according to these standards. (b) Customer entrances. Additional publicly-accessible entrances shall be provided along building elevations containing a publicly-accessible entrance at a minimum interval of 250 feet. d. Building transitions. Applicability: The following standards apply to the area located between street right-of-way and the building. (1) General requirements. (a) Fences, walls, or hedges greater than 36 inches in height are prohibited. (b) Where a building is located more than 5 feet from the right-of-way, the areas located between the right-of-way and the building must consist of pedestrian amenities, landscaping, vegetated LID BMPs, or works of art. Landscaping shall be consistent with TMC § 13.06.090B.4.h. Review of any proposed public art shall be coordinated with the City’s Arts Administrator and/or approved by the Arts Commission, as determined by the Arts Administrator. Parking is prohibited in the setback areas. (2) Residential entrances: Individual ground-related unit entrances. Each unit shall provide a transition area including one of the following features between the right-of-way and unit entrance. • | Grade changes that elevate the unit’s entrance at least 2 feet above adjacent grade. • | A common exterior amenity space meeting the requirements of 13.06.040I.3.a. • | A private exterior amenity space meeting the requirements of 13.06.040I.3.b and that includes a fence or wall to provide physical and visual separation from public spaces. (3) Residential entrances: Shared multi-unit entrances. The primary entrance shall provide a transition area between the right-of-way and entrance. Transitions can be accomplished by employing at least one of the following options: • | Grade changes that elevate the entrance at least 2 feet above adjacent grade. • | An exterior area that is at least 64 square feet with no dimension less than eight feet. (4) Pedestrian street-facing facades. (a) Where a building is located 5 feet or less from the right-of-way, the areas located between the right-of-way and the building must be hard-surfaced. e. Transparency. Purpose: The following standards are intended to increase public visibility for public safety, to provide visual interest to pedestrians that helps encourage pedestrian mobility, to provide for natural lighting to buildings interiors to conserve energy, and to provide architectural detailing and variety to building elevations on each story. (1) General requirements. • | The “ground level wall area” is defined as the area between 2 feet and 8 feet above the adjacent finished grade. • | This standard shall apply on a maximum of 2 such building elevations, and application shall be prioritized as follows: Core Pedestrian Street, Primary Pedestrian Street, Pedestrian Street, a non-Pedestrian Street, and other qualifying frontages (e.g. , the requirements would apply to the façade facing the Core Pedestrian and either the façade facing the non-designated street or the façade facing the parking lot. • | Rough openings are used to calculate this requirement. • | Reductions for sloping properties. These requirements may be reduced by 50 percent for building elevations where the finished grade level adjacent to the building is four feet above or below the level of the sidewalk. The requirement may be further reduced to 15 percent of the ground level wall area in instances where the application of this standard is not possible due to steep grades running parallel to the elevation and crossing the floor plates of the building. Diagram depicting sloping property. [image] (2) Residential buildings/uses. (a) Portions of a building containing residential uses at the ground level facing a designated Pedestrian Streets shall have transparent windows or openings equal to at least 35 percent of the ground level wall area. (b) Portions of a building containing residential uses at the ground level facing a non-Pedestrian Street, common amenity space, or an associated surface parking lot of 20 stalls or greater shall have transparent windows or openings for at least 15 percent of the ground level wall area. (c) Ancillary uses such as lobbies, mail rooms, bicycle storage, and amenity spaces shall be considered residential uses for the purposes of applying these requirements. (3) Non-residential buildings/uses, except industrial uses. (a) Portions of a building containing non-residential uses, except industrial uses, at the ground level facing a designated Core Pedestrian Street shall have transparent windows or openings equal to at least 60 percent of the ground level wall area. (b) Portions of a building containing non-residential uses, except industrial uses, at the ground level facing a designated Pedestrian Street shall have transparent windows or openings equal to at least 50 percent of the ground level wall area. (c) Portions of a building containing non-residential uses, except industrial uses, at the ground level facing a non-pedestrian street, common amenity space, or an associated surface parking lots of 20 stalls or greater shall have transparent windows or openings for at least 40 percent of the ground level wall area. (d) Required view. Required windows or openings must provide either views into building work areas, sales areas or lobbies. (e) Art or window displays may substitute for transparent elements for up to 25% of the requirement on façades facing designated Pedestrian Streets and up to 50% on all other applicable façades. (f) Window displays must be at least 2 feet in depth and recessed into the building. Display cases attached to the exterior wall do not qualify. (g) A decorative grille, work of art, or a similar treatment may be used to meet this standard on those portions of the sidewalk level façade where it can be demonstrated that the intrusion of natural light is detrimental to the sidewalk level use. Examples of such uses include, but are not limited to, movie theaters, museums, laboratories, and classrooms. In no instances shall the amount of transparency present in existing buildings be decreased below 20 percent. This standard shall also apply when 50 percent or more of the sidewalk level façade is altered. (h) Review of any proposed public art shall be coordinated with the City’s Arts Administrator and/or approved by the Arts Commission, as determined by the Arts Administrator. (4) Industrial uses. (a) Portions of a building containing industrial uses at the ground level facing a designated Pedestrian Streets shall have transparent windows or openings equal to at least 30 percent of the ground level wall area. (b) Portions of a building containing industrial uses at the ground level facing a non-Pedestrian Street, common amenity space, or an associated surface parking lots of 20 stalls or greater shall have transparent windows or openings for at least 20 percent of the ground level wall area. (c) A decorative grille, work of art, or a similar treatment may be used to meet this standard on those portions of the sidewalk level façade where it can be demonstrated that the intrusion of natural light is detrimental to the sidewalk level use. In no instances shall the amount of transparency present in existing buildings be decreased below 20 percent. This standard shall also apply when 50 percent or more of the sidewalk level façade is altered. (5) Structured parking. (a) Portions of a building containing structured parking at the ground level facing a designated Pedestrian Streets shall have transparent windows or openings equal to at least 30 percent of the ground level wall area. (b) Portions of a building containing structured parking at the ground level facing a non-Pedestrian Street, internal courtyard, plaza or an associated surface parking lot of 20 stalls or greater shall have transparent windows or openings for at least 20 percent of the ground level wall area. (c) Alternatives such as decorative grilles, artwork, display windows, or similar features can be substituted for the transparency required in that portion of the ground-level façade. Review of any proposed public art shall be coordinated with the City’s Arts Administrator and/or approved by the Arts Commission, as determined by the Arts Administrator. Figure: Development requirements for facades windows/openings [image] f. Blank walls. (1) Applicability. An area of a ground floor wall measured four feet above the adjacent finished grade that is 15 feet or more in length and faces a street, residential zone not separated by an alley, internal pathway, courtyard, plaza, or an associated surface parking lot of 20 stalls or greater that meets the definition of blank wall is subject to these requirements. (2) Requirements. These blank wall areas must employ at least one of the following treatments occupying at least 60 percent of the wall surface area and accompanied by lighting that enhances the selected treatment. More than one treatment may be used to achieve the minimum surface area coverage. • | Window display(s) at least two feet in depth and recessed into the building. Display cases attached to the exterior wall do not qualify. • | Landscape planting bed at least five feet wide or a raised planter bed at least two feet high and three feet wide in front of the wall. Such planting areas shall include planting materials that are sufficient to achieve the minimum coverage area within three years. • | Installing a vertical trellis in front of the wall with climbing vines or plant materials sufficient to achieve the minimum coverage area within three years. • | Artwork. Review of any proposed public art shall be coordinated with the City's Arts Administrator and/or approved by the Arts Commission, as determined by the Arts Administrator. 4. Building form and expression. a. Façade articulation. Applicability: Buildings greater than three stories in height must conform to the building articulation standards in subsection B.4.a(1). Buildings that have more than 60 feet of frontage along a street, open space, or parking area must conform to the articulation standards in subsection B.4.a(2). (1) Required building articulation. (a) Buildings four or five stories in height shall provide bipartite articulation by incorporating design treatments that provide a clear delineation of the building’s top and base. (b) Buildings over five stories shall provide tripartite articulation by incorporating design treatments that provide a clear delineation of the building’s top, middle, and base. (c) This articulation can be accomplished through a combination of building form, materials, and detailing. • | Top: Features may include a sloped roofline or strong cornice line. For façades utilizing upper level stepbacks, the “top” design treatment may be applied to the top of the front vertical plane of the building or the top of the building where it is set back from the building’s front vertical wall (provided the top of the building is visible from the centerline of the adjacent street). • | Middle: provide consistent articulation of middle floors with windows, balconies, exterior materials, modulation, and detailing. • | Base: provide a distinctive ground floor or lower floors design that contrasts with other floors through the use of varying window design and/or configuration, and exterior materials, architectural details, and/or other methods. (2) Optional articulation features. All buildings shall include at two of the following articulation features at intervals of no more than 30 feet along all façades facing a street, open space, or parking area. Buildings that employ brick as the siding material on a majority of the subject façade are required to only provide one of the articulation features. Modulation Choices in TMC § 13.06.100B.4.b that exceed similar options listed here can be used to satisfy these requirements if employed. (a) Repeating distinctive window patterns at intervals less than the required interval. (b) Minor vertical building modulation. Minimum depth and width of modulation is two feet and four feet, respectively, if tied to a change in building material/siding style and/or roofline modulation. (c) Major vertical building modulation. Minimum depth and width of modulation is 10 and 15 feet, respectively. (d) Horizontal modulation (upper level step-backs). Provide a minimum horizontal modulation of five feet from the building face for at least 75 percent of the facade. (e) Roofline modulation consistent with TMC § 13.06.100B.4.c(3). (f) Balconies or bay windows. To qualify, balconies must be recessed or project at least 18 inches beyond the primary building face and bay windows must project at least 18 inches beyond the primary building face. These may project into street rights-of-way, where allowed by the Public Works Department, but not into alley rights-of-way. b. Mass reduction. Purpose: The following standards are intended to reduce the appearance of bulk. Applicability: Building façades that have more than 60 feet of frontage along a public or private street, public open space, or on-site parking area (45 feet or greater average width) must conform to these standards. (1) Building modulation choices: Buildings fronting a designated Pedestrian Street must employ two of the following modulation approaches. Buildings fronting a street not designated as Pedestrian Street must employ one. (a) Horizontal modulation: Upper floor streetfront stepback (choose one as applicable). Pedestrian Street Façades: • | 8' minimum stepback along the streetfront façade for 4th floor and above in RCX Districts. • | 8' minimum horizontal stepback along the 5th floor and above in X Districts other than RCX, where the ROW width is less than 100’. • | 8' minimum horizon stepback along the 6th floor and above in X zones other than RCX, where the ROW width is 100’ or greater. • | Proportional Stepback option for any district other than RCX: An 8’ stepback along the building face above the level which corresponds to a 1:2 proportional relationship to the street Other façades: • | 5’ minimum stepback along the streetfront façade for 4th floor and above in RCX Districts. • | 5’ minimum horizontal stepback along for 5th floor and above in X Districts other than RCX, where the ROW width is less than 100’. • | 5’ minimum horizon stepback for 6th floor and above in X zones other than RCX, where the ROW width is 100’ or greater. • | Proportional Stepback option for any district other than RCX: A 5’ stepback from the building face above the level which corresponds to a 1:2 proportional relationship to the street Notes: • | Encroachments: Portions of the building may encroach vertically into these stepbacks up to 25 feet in cumulative width for each façade. • | Buildings that do not exceed the number of floors at which a stepback would apply are considered to satisfy horizontal modulation requirements for purposes of meeting mass reduction requirements. • | Portions of the building located 8' or further from a designated Pedestrian Street or 5' or further from other façades are considered to satisfy horizontal modulation requirements for purposes of meeting mass reduction requirements. For façades that face qualifying parking lots, this is measured from the improvement associated with the parking lot such as a curb or pedestrian walkway nearest the building face. (b) Vertical modulation: Façade wall width options (choose one): • | Provide vertical building modulation at least 20 feet deep and 30 feet wide. For multi-story buildings the modulation must extend through more than one-half of the building floors. • | Façade employs building walls with contrasting articulation that make it appear like two or more distinct buildings. To qualify for this option, these contrasting façades must employ the following: o | Different building materials and/or configuration of building materials. o | Contrasting window design (sizes or configurations). o | Off-set front walls – Front facing facades are off-set from the property line by a minimum 8 foot difference. (c) Common exterior amenity space. A common exterior amenity space, such as a courtyard or public plaza, of at least 800 square feet or 5 percent of site area, whichever is greater. The amenity space shall be located within 50 feet of and visible to the primary entrance; accessible to the residents and/or customers; and contain a minimum of a bench or other seating, tree, planter, fountain, kiosk, bike rack, or artwork for each 200 square feet of area. (d) Façade articulation. Employ at least two of the following select optional articulation features from TMC § 13.06.100B.4.a(2) as listed below. These features may be different or repeated to meet this requirement. • | Minor vertical building modulation. Minimum depth and width of modulation is two feet and four feet, respectively, if tied to a change in building material/siding style and/or roofline modulation. • | Major vertical building modulation. Minimum depth and width of modulation is 10 and 15 feet, respectively. • | Horizontal modulation (upper level stepbacks). Provide a minimum horizontal modulation of five feet from the building face for at least 75 percent of the facade. • | Roofline modulation consistent with TMC § 13.06.100B.4.c(3). • | Balconies. To qualify, balconies must be recessed at least 18 inches from the primary building face. Example Figures:Diagram depicting horizontal modulation. [image] Articulation examples of mixed-use buildings containing residential uses on upper floors. These examples include vertical and horizontal modulation and changes in building materials at no more than 30-foot articulation intervals. [image] Examples of façades that effectively use techniques to reduce the apparent bulk and scale of the structure. The image on the left uses street and upper level courtyards whereas the right image uses both vertical building modulation and the use of contrasting building materials and articulation. [image] c. Light and air access for residential units. Every residential unit shall have access to a minimum amount of light, direct or indirect, and air per these requirements. Units that face a side or rear property line or an internal exterior space shall provide sufficient separation as follows. Units that directly face a street, alley, other public rights-of-way, or land determined to be undevelopable are exempt. (1) Units that only face a side or rear property line shall be set back from the property line at least eight feet for a width of at least 10 feet. (2) Units that only face an internal exterior space, such as a courtyard or light well, shall be no closer than 15 feet from any parallel wall. (3) Units that face a side or rear property line and an internal exterior space is required to only meet subsection B.4.c(1) or (2) above. (4) Every unit shall be afforded at least 10 feet of total exterior wall width and each shall include at least one operable window. (5) Private amenity spaces, such as balconies, may encroach up to 5 feet into this space. Example Figures:Examples of buildings that meet minimum light and air standards for residential units. [image] d. Roofline design. (1) General requirements. • | Buildings employing a flat roof must meet the standards in TMC § 13.06.100B.4.c(2). • | The length of any continuous roofline visible from a street, open space, or associated parking lot shall that extends more than 100 feet shall employ roofline modulation consistent with the standards described below. • | Buildings employing roofline modulation for the purposes of satisfying TMC § 13.06.100B.4.a(2)(e) shall be consistent with the roofline modulation standards described below. (2) Flat roof standards. Buildings or portions thereof featuring flat roofs (horizontal roofs with either no slope or only a slope sufficient to effect drainage, often which incorporate surrounding parapets) shall employ roofline treatments incorporating one or more of the following design elements along façades facing a street. (a) A cornice of two parts with the top projecting at least 6 inches from the face of the building and at least 2 inches further from the face of the building than the bottom part of the cornice. The height of the cornice shall be at least 12-inches high for buildings 10 feet or less in height; 18-inches for buildings greater than 10 feet and less than 30 feet in height; and 24-inches for buildings 30 feet and greater in height. The cornice must extend along at least 75 percent of the façade. (b) Use of balcony/deck railings that function as a roofline treatment. Such railings must be at least 2 feet in height and extend along at least 75 percent of the façade and shall be visible from the adjacent street centerline. (c) Use of contrasting building materials on the top floor or top two floors for buildings five stories or taller, for at least 75 percent of the façade. (3) Roofline modulation. Roofline modulation is not required of all buildings. However, where required or otherwise applied, the roofline shall meet the following modulation requirements. Whether the roof is flat or pitched, roofline modulation can be accomplished through either vertical or horizontal roofline articulation or a combination of both that breaks up the dominant roof form to enhance visual interest. (a) Vertical articulation can be achieved by incorporating any vertically-oriented change to the roofline. This can include stepped parapets, dormer, gables, domes, turrets or other projecting elements. The minimum vertical dimension of roofline modulation is 2 feet when combined with vertical building modulation of or 4 feet when it is not. (b) Horizontal articulation can be achieved by incorporating a horizontally-oriented change to the roofline. This can include recessing the peak of the roofline from the building face with a pitched roof, vertical building modulation, or other methods that provide horizontal changes within the roof form. If vertical building modulation is to be used to provide horizontal roofline modulation, the building modulation shall meet the minimum requirements of TMC § 13.06.100B.4.a(2) or 13.06.100B.4.b(1)(b). (c) Modulating elements shall equal a minimum of 15 percent of each elevation’s roofline. (4) Roofline elements shall not project over property lines, except where permitted on property lines abutting public right-of-way. (5) Canopy exemption. Fueling station canopies, drive through canopies, or similar canopies are exempt from roofline requirements. e. Transparency. Purpose: The following standards are intended to increase public visibility for public safety, to provide visual interest to pedestrians that helps encourage pedestrian mobility, to provide for natural lighting to buildings interiors to conserve energy, and to provide architectural detailing and variety to building elevations on each story. (1) General requirements. • | Rough openings are used to calculate this requirement. (2) Residential buildings and residential portions of mixed-use buildings. (a) Portions of a building containing residential uses facing a street shall have transparent windows or openings equal to at least 15 percent of the wall area. (b) Portions of a building containing residential uses facing an internal courtyard, plaza or an associated surface parking lot of 20 stalls or greater shall have transparent windows or openings for at least 10 percent of the wall area. (c) Ancillary uses such as lobbies, mail rooms, bicycle storage, and amenity spaces shall be considered residential uses for the purposes of applying these requirements. (3) Non-residential buildings, non-residential portions of mixed-use buildings, and structured parking. (a) Portions of a building containing non-residential uses, including structured parking, facing a street or associated surface parking lot shall use a combination of transparent windows or openings and architectural relief that provide visual demarcation of each floor. (b) Upper level windows shall be a different type than the ground level windows on the same elevation. (c) For purposes of this requirement, a window type is either a grouping of windows, a window size, or a window shape. C. Multi-unit residential minimum design standards (in non-Urban Residential Districts). 1. Purpose. The design standards of this section are required to implement the urban design goals of the Comprehensive Plan of the City of Tacoma. 2. Applicability. The building design standards apply to all new development of mixed-use or multi-unit residential consisting of four or more units, as outlined below, except as follows: a. Standards. Each item of this section shall be addressed individually. Exceptions and exemptions noted for specific development situations apply only to the item noted. b. Alterations. (1) Three thresholds are used to gauge the extent of design standard compliance on alterations to existing development: Level I alterations include all remodels and/or additions within a two year period whose cumulative value is less than 50% of the value of existing development or structures, as determined by the applicable Building Code. The requirement for such alterations is only that the proposed improvements meet the standards and do not lead to further nonconformance with the standards. For example, if a property owner decides to replace a building façade’s siding, then the siding shall meet the applicable exterior building material standards, but elements such as building modulation would not be required. Level II alterations include all remodels and/or additions within a two year period whose cumulative value ranges from 50% to 200% of the value of the existing development or structure, as determined by the applicable Building Code. All standards that do not involve repositioning the building or reconfiguring site development shall apply to Level II alterations. Level III alterations include all remodels and/or additions within a two year period whose cumulative value exceeds 200% of the value of the existing development or structure, as determined by the applicable Building Code. Such alterations shall conform to ALL standards. (2) The standards do not apply to remodels that do not change the exterior form of the building. However, if a project involves both exterior and interior improvements, then the project valuation shall include both exterior and interior improvements. (3) No addition or remodel shall increase the level of nonconformity or create new nonconformities to the development or design standards. c. Super regional malls. Additions to super regional malls of less than 10,000 square feet of floor area are exempt from the design standards of this section. d. Temporary. Temporary structures are exempt from the design standards of this section. e. Residential and/or mixed-use. (1) Single, two, and three-unit dwellings and townhomes are subject to design standards as noted elsewhere in this Chapter. (2) Middle housing developments in Urban Residential (UR) Districts are subject only to the design standards in Subsection F of this Chapter. f. Historic. In any conflict between these standards and those applied by the Tacoma Landmarks Preservation Commission, the standards of the commission shall prevail. g. Religious assembly facilities which can demonstrate that the design standards impose a substantial burden, administratively or financially, on their free exercise of religion, shall be exempt from compliance. h. Floor area. For purposes of this section of the code (Section 13.06.100), “floor area” shall not include spaces below grade. i. Parks, recreation and open space uses. Accessory or ancillary structures, such as restroom buildings, playground equipment and picnic shelters, are exempt from the design standards of this section. 3. Zoning District applicability. The following requirements apply to multi-unit residential developments in all districts, except, see § 13.06.100B Mixed-Use District Minimum Design Standards for X-District requirements, § 13.06.100D for Downtown Minimum Design Standards, § 13.06.100F for Urban Residential (UR) District requirements, and multi-unit residential development with commercial ground floor uses are subject to the requirements of § 13.06.100A Commercial District Minimum Design Standards. 4. Pedestrian orientation standards. Purpose: These requirements are intended to enhance pedestrian mobility and safety by providing increased circulation, decreasing walking distances required to enter large developments, and providing walkways partially shielded from rain and/or snow. a. Entrances. (1) Buildings meeting the “build-to area” for designated pedestrian streets shall provide at least 1 entrance within 8 feet of the longest street facing wall of the building. Buildings that have a shared main entrance must use the shared main entrance to fulfill the requirements of this standard. (a) The shared main entrance must face the street or be at an angle of up to 45 degrees from the street. (b) The shared main entrance may open onto a porch. The porch must have a minimum dimension of 4 feet by 6 feet; have a roof that is no more than 12 feet above the floor of the porch; and be at least 30 percent solid. If at least 30 percent of the porch is covered with a solid roof, the rest may be covered with an open material, such as a trellis. (2) Weather protection is required for all multi-unit building entries. For private entries, required weather protection must be at least 3 feet deep along the width of the entry. For common building entries, the required weather protection shall be 5 feet. 5. Mass reduction standards. Purpose: The following standards are intended to help reduce the apparent mass of structures and achieve a more human scale environment by providing physical breaks in the building volume that reduce large, flat, geometrical planes on any given building elevation. a. Size to choice ratio for b below. (1) Buildings under 7,000 square feet of floor area are not required to provide mass reduction. (2) Buildings from 7,000 square feet of floor area to 30,000 square feet of floor area shall provide at least one mass reduction feature. (3) Buildings over 30,000 square feet of floor area shall provide at least two mass reduction features. b. Mass reduction choices. (1) Upper story setback. An 8 feet minimum setback for stories above the second story for elevations facing the street or parking lots over 20 stalls. This requirement applies to a maximum of 2 elevations. (2) Wall modulation. Maximum 100 feet of wall without modulation, then a minimum 2 feet deep and 15 feet wide offset of the wall and foundation line on each elevation facing the street, parking lots over 20 stalls, or residential uses. (3) Plaza. A plaza of at least 800 square feet or 5 percent of building floor area, whichever is greater shall be located within 50 feet of, and visible to, the primary public entrance; and such plaza shall contain a minimum of a bench or other seating, tree, planter, fountain, kiosk, bike rack, or art work for each 200 square feet of plaza area. Plaza features may be counted toward other requirements, including landscaping and usable yard space standards. Walkways do not count as plazas. Plazas shall not be used for storage. Required parking stalls may be omitted to the minimum necessary if needed to provide the plaza. Where public seating is provided, it shall utilize designs that discourage long-term loitering or sleeping, such as dividers or individual seating furniture. Plazas may be permeable pavement or pavers where feasible. Low Impact Development vegetated stormwater features may be used for up to 30% of the plaza requirement where feasible. Figures: Upper Story Setback; Wall Modulation Example; Public Plaza Example [image] [image] [image] 6. Roofline standards. Purpose: The following standards are intended to ensure that roofline is addressed as an integral part of building design to avoid flat, unadorned rooflines that can result in an industrial appearing, monotonous skyline. Roofline features are also intended to further reduce apparent building volume and further enhance features associated with residential and human scale development. a. Roofline choices. (All buildings shall use one or more of the roofline options.) (1) Sloped roof. Use of a roof form with a pitch no flatter than 5/12. Rounded, gambrel, and/or mansard forms may be averaged. (2) Modulated roof. Use of features, which are a minimum of 2 feet in height, such as a terracing parapet, multiple peaks, jogged ridge lines, dormers, etc., with a maximum of 100 feet uninterrupted roofline between roof modulation elements. Modulation elements shall equal a minimum of at least 15 percent of the roofline on each elevation. The maximum shall be 50 feet of uninterrupted roofline along the eave between roof modulation elements in C 1 Districts and on sides facing residential uses or districts. Roof forms with a pitch flatter than 5/12 are permitted with this option; provided, the appropriate modulation is incorporated. (3) Corniced roof. A cornice of two parts with the top projecting at least 6 inches from the face of the building and at least 2 inches further from the face of the building than the bottom part of the cornice. The height of the cornice shall be at least 12 inches high for buildings 10 feet or less in height; 18 inches for buildings greater than 10 feet and less than 30 feet in height; and 24 inches for buildings 30 feet and greater in height. Cornices shall not project over property lines, except where permitted on property lines abutting public right-of-way. Figure: Roofline Examples [image] | Figure: Modulated Roof Example [image] | Figure: Cornice Example [image] 7. Windows and openings. Purpose: These requirements are intended to increase public visibility for public safety, to provide visual interest to pedestrians that helps to encourage pedestrian mobility, to provide a visual connection between the living area of the residence and the street, and to provide architectural detailing and variety to building elevations on each story. a. Street level. (1) Front, side, or corner side exterior walls facing designated pedestrian streets shall have transparent windows or openings equal to at least 35 percent of the ground level wall area. Rough openings are used to calculate this requirement. This standard shall apply on a maximum of 2 such building elevations. The requirement shall be reduced to 15 percent of the ground level wall area in instances where the application of this standard is not possible due to steep grades and the correlating location of the floor plates of the building. Rough openings are used to calculate this requirement. Windows in garage doors do not count toward meeting this standard, but windows in garage walls do count toward meeting this standard. To count toward meeting this standard a door must be facing the street property line. (2) The “ground level wall area” is defined as the area between 2 feet and 8 feet above the adjacent finished grade. b. Transparency. Vertical façade surfaces facing a street shall incorporate transparent doors and windows equal to at least 15% of all vertical façade surfaces. Vertical façade surfaces facing alleys, courtyards, plazas, and surface parking lots shall incorporate transparent doors and windows equal to at least 10% of all vertical façade surfaces. Rough openings are used to calculate this requirement. Windows in garage doors do not count toward meeting this standard, but windows in garage walls do count toward meeting this standard. c. Window and trim detailing. Building façades shall employ techniques to recess or project individual windows or groupings of windows above the ground floor at least two inches from the surrounding façade or incorporate window trim at least four inches wide surrounding the windows. Windows on façades that face the rear property line or alleys are exempt from this standard. Recessed window OK [image] | Projected window OK [image] | Window with trim OK [image] Unacceptable [image] 8. Façade surface standards. Purpose: The following standards are intended to help reduce the apparent mass of structures and achieve a more human scale environment by providing visual breaks at more frequent intervals to the building volume that reduce large, flat, geometrical planes on any given building elevation, especially at the first story. The choices are also intended to encourage variety in the selection of façade materials and/or treatment and to encourage more active consideration of the surrounding setting. a. Building face orientation. All dwellings shall maintain primary orientation to an adjacent street or right-of-way and not toward the alley or rear of the site, unless otherwise determined by the Director. The building elevation facing the street or right-of-way shall not contain elements commonly associated with a rear elevation appearance, such as loading docks, utility meters, and/or dumpsters. b. All residential buildings shall include at least three of the following articulation features at intervals of no more than 30 feet along all façades facing a street, common open space, or common parking areas. Buildings that have 60 feet or less of frontage on the street or façade width facing the common open space or common parking area are exempt from this standard. Buildings that employ brick as the siding material on a majority of the subject façade are required to only provide two of the articulation features instead of three. (1) Repeating distinctive window patterns at intervals less than the required interval. (2) Vertical building modulation. Minimum depth and width of modulation is 2 feet and 4 feet, respectively, if tied to a change in building material/siding style and/or roofline modulation. Otherwise, minimum depth and width of modulation is 2 and 15 feet, respectively. Balconies may not be used to meet modulation option unless they are recessed or projected from the façade at least 18 inches. (3) Horizontal modulation (upper level step-backs). To qualify for this measure, the minimum horizontal modulation shall be 5 feet and the treatment must be used in increments at no greater than the articulation interval or provided along more than 75 percent of the façade. (4) Roofline modulation. (5) Vertical articulation of the façade. This refers to design treatments that provide a clear delineation of the building’s top, middle and bottom. (a) Top features may include a sloped roofline or strong cornice line as defined in Section 13.06.501.D.4. For façades utilizing upper level stepbacks, the “top” design treatment may be applied to the top of the front vertical plane of the building or the top of the building where it is set back from the building’s front vertical wall (provided the top of the building is visible from the centerline of the adjacent street). (b) Middle features: provide consistent articulation of middle floors with windows, balconies, exterior materials, modulation, and detailing. (c) Bottom: provide a distinctive ground floor or lower floors design that contrasts with other floors through the use of both contrasting window design/configuration and contrasting exterior materials. (d) Façade reduction elements including balconies and bay windows may project into street rights-of-way, where allowed by the Public Works Department, but not into alley rights-of-way. Above: Residential building articulation at intervals of 30-foot or less. [image] c. Blank walls. (1) Applicability. A blank wall on the first story that is more than 25 feet in length and faces a public street and/or highway right-of-way, residential zone, or customer parking lot is subject to these requirements. (2) Requirements. These blank wall areas must employ at least one of the following treatments to create a visual break between blank wall segments. The visual break treatment must be at least one foot in width and employed at least every 25 feet. Stored or displayed merchandise, pipes, conduit, utility boxes, air vents, and/or similar equipment do not count toward this requirement. • | Building modulation; • | Windows; • | Openings; • | Landscaping; • | Architectural relief, such as visibly different textured material. 9. Rooftop Utilities. Purpose: The following standards are intended to minimize visibility of utilities, mechanical equipment, and service areas to mitigate visual impact on residential privacy, public views, and general community aesthetics. All rooftop mechanical equipment for new construction shall be screened with an architectural element such as a high parapet, a stepped or sloped roof form or an equivalent architectural feature which is at least as high as the equipment being screened. Fencing is not acceptable. The intent of the screening is to make the rooftop equipment minimally visible from public rights-of-way within 125 feet of the building, provided said rights-of-way are below the roof level of the building. In those instances where the rights-of-way within 125 feet of the building are above the roof level of the building, the mechanical equipment should be the same color as the roof to make the equipment less visible. Limited flexibility in this standard is allowed to ensure that the function of the HVAC equipment is not compromised by the screening requirement. Figure: Utility Storage [image] D. Downtown District minimum design standards. 1. General applicability. The design standards of this section are required to implement the urban design goals of the Comprehensive Plan of the City of Tacoma. The basic design standards, except as otherwise noted, shall apply to all new construction, additions, and substantial alterations. a. Standards. Each item of this section shall be addressed individually. Exceptions and exemptions noted for specific development situations apply only to the item noted. Additional standards are applicable to the DCC and DR Districts, see below. b. Alterations. (1) Three thresholds are used to gauge the extent of design standard compliance on alterations to existing development: Level I alterations include all remodels and/or additions within a two year period whose cumulative value is less than 50% of the value of existing development or structures, as determined by the applicable Building Code. The requirement for such alterations is only that the proposed improvements meet the standards and do not lead to further nonconformance with the standards. For example, if a property owner decides to replace a building façade’s siding, then the siding shall meet the applicable exterior building material standards, but elements such as building modulation would not be required. Level II alterations include all remodels and/or additions within a two year period whose cumulative value ranges from 50% to 200% of the value of the existing development or structure, as determined by the applicable Building Code. All standards that do not involve repositioning the building or reconfiguring site development shall apply to Level II alterations. Level III alterations include all remodels and/or additions within a two year period whose cumulative value exceeds 200% of the value of the existing development or structure, as determined by the applicable Building Code. Such alterations shall conform to ALL standards. (2) The standards do not apply to remodels that do not change the exterior form of the building. However, if a project involves both exterior and interior improvements, then the project valuation shall include both exterior and interior improvements. (3) No addition or remodel shall increase the level of nonconformity or create new nonconformities to the development or design standards. c. Variances. A variance to the required standards may be authorized, pursuant to Section 13.05.010B. d. Temporary. Temporary structures are exempt from the design standards of this section. e. Residential and/or mixed-use. (1) Single, two, and three-unit dwellings are subject only to the design standards in Subsection E. Townhouses are subject only to the design standards in Subsection H. For other residential uses, such as mixed-use buildings and multi-unit dwellings of 4 units or more, the standards herein apply unless otherwise noted. (2) Single-unit dwellings legally established prior to August 1, 2011, are exempt from these standards. However, remodels and additions to such single-unit dwellings shall not increase the level of nonconformity. f. Historic. In any conflict between these standards and those applied by the Tacoma Landmarks Preservation Commission, the standards of the commission shall prevail. g. Religious assembly facilities which can demonstrate that the design standards impose a substantial burden, administratively or financially, on their free exercise of religion, shall be exempt from compliance. h. Parks, recreation and open space uses. Accessory or ancillary structures, such as restroom buildings, playground equipment and picnic shelters, are exempt from the design standards of this section. 2. Zoning District applicability. The following requirements apply to all development located in any Downtown District, except where noted or unless specifically exempted. 3. Ground level design. a. Façade details & articulation. Applicability: All building façades fronting a designated Pedestrian Street must include the following required and selected articulation features at intervals no greater than 40 feet. Buildings that have 60 feet or less of frontage on the designated pedestrian street are exempt from this standard. (1) Required features: DCC zoning. (a) The floor area abutting at least 50 percent of the linear sidewalk level frontage shall meet the following standards, in addition to any other required basic or additional design standards. • | The distance from the finished floor to the finished ceiling above shall be at least 12 feet. • | The interior area must have a minimum average depth of 25 feet measured from the sidewalk level façade. • | Use of vertical piers (minimum 2 inch projection) and arrangement of windows and/or entries that reinforce the pattern of small storefront spaces. (2) Required features: Other Downtown zones (non-DCC). (a) The floor area abutting at least 25 percent of the linear sidewalk level frontage shall meet the following standards, in addition to any other required basic or additional design standards. • | The distance from the finished floor to the finished ceiling above shall be at least 12 feet. • | The interior area must have a minimum average depth of 25 feet measured from the sidewalk level façade. • | Use of vertical piers (minimum 2 inch projection) and arrangement of windows and/or entries that reinforce the pattern of small storefront spaces. (3) Optional features: Choose one from each of the following categories: (a) Window and/or entry treatment: • | Display windows divided into a grid of multiple panes. • | Transom windows. • | Roll-up windows/doors. • | Recessed entry. • | Decorative door. • | Arcade. • | Landscaped trellises or other permanent decorative elements that incorporate landscaping near the building entry. (b) Building materials and other façade elements: • | Decorative weather protection element(s) such as a steel canopy or glass, fixed-fabric, or retractable awning. • | Decorative building-mounted light fixtures. • | Use of brick, stonework, and architectural pre-cast concrete for at least 10 percent of siding material on the façade. • | Incorporating a decorative mix of building materials. • | Decorative kick-plate, pier, or belt course. Example FiguresThese figures all depict acceptable façade articulation examples.All use window configurations to reinforce the desired small storefront pattern. This building uses roofline modulation, window configurations, and weather protection elements to reinforce the pattern of small storefronts. [image] This building employs a regular pattern of vertical piers. [image] This building incorporates different weather protection elements. [image] b. Weather protection. (1) General requirements. (a) Weather projection may be composed of awnings, canopies, arcades, overhangs, marquees, or similar architectural features. (b) Weather protection must cover at least 5 feet in width of the public or semi-public sidewalk but reduced to accommodate trees, lighting, bay windows, or similar building features to not less than 3 feet in width. (2) Minimum requirements. (a) Pedestrian Street-facing building facades. Weather protection shall be provided above all entrances and along a minimum of 80 percent of ground level building facades abutting or located within 5 feet of a hard-surfaced public or private sidewalk, walkway, and/or amenity space. (b) Building facades facing a non-Pedestrian Street or common amenity space. Weather protection shall be provided above all entrances and along a minimum of 50 percent of ground level building facades abutting or located within 5 feet of a hard-surfaced public or private sidewalk, walkway, and/or amenity space. c. Building orientation & entrances. (1) Residential buildings/uses. (a) Location. Primary entrances must be oriented to the abutting street and must include features that visually communicate its prominence and function such as signage, weather protection, wayfinding, pedestrian lighting, landscaping, walls/fences, etc. If the building has more than one street frontage where one is a designated Pedestrian Street, the Primary Entrance must be oriented to the Pedestrian Street except that the Primary Entrance for residential units within a mixed-use building may be located on non-Pedestrian Street for buildings so long as a Primary Entrance for the Non-residential uses are provided along the Pedestrian Street. If no entrance clearly meets the definition of a Primary Entrance, at least one entrance must be designated as such and designed according to these standards. (b) Dimensions. A covered space of weather protection is required for all building/use entries. Each Primary Entrance must include a covered space that is at least four feet wide and six feet deep except for developments that only include individual, ground-related unit entrances (see below). This space may either be recessed or projecting from the front building wall and may encroach into the right-of-way. The weather protection cover may not be more than 12 feet above grade. (2) Non-residential buildings/uses. (a) Location. A publicly-accessible Primary Entrance must be oriented to the abutting street, located within 20 feet of the street, and must include features that visually communicate its prominence and function such as signage, weather protection, wayfinding, pedestrian lighting, landscaping, walls/fences, etc. If the building has more than one street frontage where one is a designated Pedestrian Street, the primary entrance must be oriented to the Pedestrian Street. If no entrance clearly meets the definition of a Primary Entrance, at least one entrance must be designated as such and designed according to these standards. (b) Customer entrances. Additional publicly-accessible entrances shall be provided along building elevations containing a publicly-accessible entrance at a minimum interval of 250 feet. d. Building transitions. Applicability: The following standards apply to the area located between street right-of-way and the building. (1) General requirements. (a) Fences, walls, or hedges greater than 36 inches in height are prohibited. (b) Where a building is located more than 5 feet from the right-of-way, the areas located between the right-of-way and the building must consist of pedestrian amenities, landscaping, vegetated LID BMPs, or works of art. Landscaping shall be consistent with TMC § 13.06.090B.4.h. Review of any proposed public art shall be coordinated with the City’s Arts Administrator and/or approved by the Arts Commission, as determined by the Arts Administrator. Parking is prohibited in the setback areas. (2) Residential entrances: Individual ground-related unit entrances. Each unit shall provide a transition area including one of the following features between the right-of-way and unit entrance. • | Grade changes that elevate the unit’s entrance at least 2 feet above adjacent grade. • | A common exterior amenity space meeting the requirements of 13.06.040I.3.a. • | A private exterior amenity space meeting the requirements of 13.06.040I.3.b and that includes a fence or wall to provide physical and visual separation from public spaces. (3) Residential entrances: Shared multi-unit entrances. The primary entrance shall provide a transition area including one of the following features between the right-of-way and entrance. • | Grade changes that elevate the entrance at least two feet above adjacent grade. • | An exterior area that is at least 64 square feet with no dimension less than eight feet. (4) Pedestrian street-facing facades. (a) Where a building is located 5 feet or less from the right-of-way, the areas located between the right-of-way and the building must be hard-surfaced. e. Transparency. Purpose: The following standards are intended to increase public visibility for public safety, to provide visual interest to pedestrians that helps encourage pedestrian mobility, to provide for natural lighting to buildings interiors to conserve energy, and to provide architectural detailing and variety to building elevations on each story. (1) General requirements. • | The “ground level wall area” is defined as the area between 2 feet and 8 feet above the adjacent finished grade. • | This standard shall apply on a maximum of 2 such building elevations, and application shall be prioritized as follows: Primary Pedestrian Street, Pedestrian Street, a non-Pedestrian Street, and other qualifying frontages (e.g., the requirements would apply to the façade facing the Core Pedestrian and either the façade facing the non-designated street or the façade facing the parking lot. • | Rough openings are used to calculate this requirement. • | Reductions for sloping properties. These requirements may be reduced by 50 percent for building elevations where the finished grade level adjacent to the building is four feet above or below the level of the sidewalk. The requirement may be further reduced to 15 percent of the ground level wall area in instances where the application of this standard is not possible due to steep grades running parallel to the elevation and crossing the floor plates of the building. Diagram depicting sloping property. [image] (2) Residential buildings/uses. (a) Portions of a building containing residential uses at the ground level facing a designated Pedestrian Streets shall have transparent windows or openings equal to at least 35 percent of the ground level wall area. (b) Portions of a building containing residential uses at the ground level facing a non-Pedestrian Street, common amenity space, or an associated surface parking lot of 20 stalls or greater shall have transparent windows or openings for at least 20 percent of the ground level wall area. (c) Ancillary uses such as lobbies, mail rooms, bicycle storage, and amenity spaces shall be considered residential uses for the purposes of applying these requirements. (3) Non-residential buildings/uses, except industrial uses. (a) Portions of a building containing non-residential uses, except industrial uses, at the ground level facing a designated Pedestrian Street shall have transparent windows or openings equal to at least 60 percent of the ground level wall area. (b) Portions of a building containing non-residential uses, except industrial uses, at the ground level facing a non-pedestrian street, common amenity space, or an associated surface parking lots of 20 stalls or greater shall have transparent windows or openings for at least 40 percent of the ground level wall area. (c) Required view. Required windows or openings must provide either views into building work areas, sales areas or lobbies. (d) Art or window displays may substitute for transparent elements for up to 25% of the requirement on façades facing designated Pedestrian Streets and up to 50% on all other applicable façades. (e) Window displays must be at least 2 feet in depth and recessed into the building. Display cases attached to the exterior wall do not qualify. (f) A decorative grille, work of art, or a similar treatment may be used to meet this standard on those portions of the sidewalk level façade where it can be demonstrated that the intrusion of natural light is detrimental to the sidewalk level use. Examples of such uses include, but are not limited to, movie theaters, museums, laboratories, and classrooms. In no instances shall the amount of transparency present in existing buildings be decreased below 20 percent. This standard shall also apply when 50 percent or more of the sidewalk level façade is altered. (g) Review of any proposed public art shall be coordinated with the City’s Arts Administrator and/or approved by the Arts Commission, as determined by the Arts Administrator. (4) Industrial uses. (a) Portions of a building containing industrial uses at the ground level facing a designated Pedestrian Streets shall have transparent windows or openings equal to at least 30 percent of the ground level wall area. (b) Portions of a building containing industrial uses at the ground level facing a non-Pedestrian Street, common amenity space, or an associated surface parking lots of 20 stalls or greater shall have transparent windows or openings for at least 20 percent of the ground level wall area. (c) A decorative grille, work of art, or a similar treatment may be used to meet this standard on those portions of the sidewalk level façade where it can be demonstrated that the intrusion of natural light is detrimental to the sidewalk level use. In no instances shall the amount of transparency present in existing buildings be decreased below 20 percent. This standard shall also apply when 50 percent or more of the sidewalk level façade is altered. (5) Structured parking. (a) Portions of a building containing structured parking at the ground level facing a designated Pedestrian Streets shall have transparent windows or openings equal to at least 30 percent of the ground level wall area. (b) Portions of a building containing structured parking at the ground level facing a non-Pedestrian Street, internal courtyard, plaza or an associated surface parking lot of 20 stalls or greater shall have transparent windows or openings for at least 20 percent of the ground level wall area. (c) Alternatives such as decorative grilles, artwork, display windows, or similar features can be substituted for the transparency required in that portion of the ground-level façade. Review of any proposed public art shall be coordinated with the City’s Arts Administrator and/or approved by the Arts Commission, as determined by the Arts Administrator. Figure: Development requirements for facades windows/openings [image] f. Blank walls. (1) Applicability. An area of a ground floor wall measured four feet above the adjacent finished grade that is 15 feet or more in length and faces a street, residential zone not separated by an alley, internal pathway, courtyard, plaza, or an associated surface parking lot of 20 stalls or greater that meets the definition of blank wall is subject to these requirements. (2) Requirements. These blank wall areas must employ at least one of the following treatments occupying at least 60 percent of the wall surface area and accompanied by lighting that enhances the selected treatment. More than one treatment may be used to achieve the minimum surface area coverage. • | Window display(s) at least two feet in depth and recessed into the building. Display cases attached to the exterior wall do not qualify. • | Landscape planting bed at least five feet wide or a raised planter bed at least two feet high and three feet wide in front of the wall. Such planting areas shall include planting materials that are sufficient to achieve the minimum coverage area within three years. • | Installing a vertical trellis in front of the wall with climbing vines or plant materials sufficient to achieve the minimum coverage area within three years. • | Artwork. Review of any proposed public art shall be coordinated with the City's Arts Administrator and/or approved by the Arts Commission, as determined by the Arts Administrator. 4. Building form and expression. a. Façade articulation. Applicability: Buildings greater than 3 stories in height must conform to the building articulation standards in section (1). Buildings zoned DR that have more than 60 feet of frontage along a street, open space, or parking area must conform to the articulation standards in section (2). (1) Required building articulation for buildings 4 to 10 stories in height in all zoning districts. Buildings greater than 10 stories in height are exempt from these requirements. For the purposes of applying this requirement, floor heights are counted from the street-facing façade containing the Primary Entrance. (a) Buildings 4 or 5 stories in height shall provide bipartite articulation by incorporating design treatments that provide a clear delineation of the building’s top and base. (b) Buildings over 5 stories shall provide tripartite articulation by incorporating design treatments that provide a clear delineation of the building’s top, middle, and base. (c) This articulation can be accomplished through a combination of building form, materials, and detailing. • | Top: Features may include a sloped roofline or strong cornice line. For façades utilizing upper level stepbacks, the “top” design treatment may be applied to the top of the front vertical plane of the building or the top of the building where it is set back from the building’s front vertical wall (provided the top of the building is visible from the centerline of the adjacent street). • | Middle: provide consistent articulation of middle floors with windows, balconies, exterior materials, modulation, and detailing. • | Base: provide a distinctive ground floor or lower floors design that contrasts with other floors through the use of varying window design and/or configuration, and exterior materials, architectural details, and/or other methods. (2) Optional articulation features for development within the DR zoning district. Development within other zones are exempt. All buildings shall include at two of the following articulation features at intervals of no more than 30 feet along all façades facing a street, common open space, or common parking areas. Buildings that employ brick as the siding material on a majority of the subject façade are required to only provide one of the articulation features. Buildings that have 60 feet or less of frontage on the street or façade width facing the common open space or common parking area are exempt from this standard. Modulation Choices in TMC § 13.06.100B.4.b that exceed similar options listed here can be used to satisfy these requirements if employed. (a) Repeating distinctive window patterns at intervals less than the required interval. (b) Minor vertical building modulation. Minimum depth and width of modulation is 2 feet and 4 feet, respectively, if tied to a change in building material/siding style and/or roofline modulation. (c) Major vertical building modulation. Minimum depth and width of modulation is 10 and 15 feet, respectively. (d) Horizontal modulation (upper level step-backs). Provide a minimum horizontal modulation of 5 feet from the building face for at least 75 percent of the facade. (e) Roofline modulation consistent with TMC § 13.06.100B.4.c(3). (f) Balconies or bay windows. To qualify, balconies must be recessed or project at least 18 inches beyond the primary building face and bay windows must project at least 18 inches beyond the primary building face. These may project into street rights-of-way, where allowed by the Public Works Department, but not into alley rights-of-way. Figures: [image] b. Mass reduction. Purpose: The following standards are intended to reduce the appearance of bulk. Applicability: Building façades that have more than 60 feet of frontage along a public or private street, public open space, or on-site parking area (45 feet or greater average width) must conform to these standards, except where exempted. (1) Building modulation choices: Buildings fronting a designated Pedestrian Street must employ two of the following modulation approaches. Building fronting a street not designated as Pedestrian Street must employ one. This requirement applies to buildings 4 to 10 stories in height in all districts. Buildings greater than 10 stories in height are exempt from these requirements. For the purposes of applying this requirement, floor heights are counted from the street-facing façade containing the Primary Entrance. (a) Horizontal modulation: Upper floor streetfront stepback measured from the building face closest to the street (choose one as applicable) Pedestrian street façades: • | 8' minimum horizontal stepback along the 5th floor and above where the ROW width is less than 100'. • | 8' minimum horizon stepback along the 6th floor and above where the ROW width is 100’ or greater. • | Proportional Stepback option: A 8' stepback along the building face above the level which corresponds to a 1:2 proportional relationship to the street. Other façades: • | 5' minimum horizontal stepback along the 5th floor and above where the ROW width is less than 100'. • | 5' minimum horizon stepback along the 6th floor and above where the ROW width is 100' or greater. • | Proportional Stepback option: A 5' stepback along the building face above the level which corresponds to a 1:2 proportional relationship to the street. Notes: • | Encroachments: Portions of the building may encroach vertically into these stepbacks up to 25 feet in cumulative width for each façade. • | Buildings that do not exceed the number of floors at which a stepback would apply are considered to satisfy horizontal modulation requirements for purposes of meeting mass reduction requirements. • | Portions of the building located 8' or further from a designated Pedestrian Street or 5' or further from other façades are considered to satisfy horizontal modulation requirements for purposes of meeting mass reduction requirements. For façades that face qualifying parking lots, this is measured from the improvement associated with the parking lot such as a curb or pedestrian walkway nearest the building face. (b) Vertical modulation: Façade Wall Width Options (choose one) • | Provide vertical building modulation at least 20 feet deep and 30 feet wide. For multi-story buildings the modulation must extend through more than one-half of the building floors. • | Façade employs building walls with contrasting articulation that make it appear like two or more distinct buildings. To qualify for this option, these contrasting façades must employ the following: • | Different building materials and/or configuration of building materials. • | Contrasting window design (sizes or configurations). • | Off-set front walls – Front facing facades are off-set from the property line by a minimum 8-foot difference. (c) Common exterior amenity space. A common exterior amenity space, such as a courtyard or public plaza, of at least 800 square feet or 5 percent of site area, whichever is greater. The amenity space shall be located within 50 feet of and visible to the primary entrance; accessible to the residents and/or customers; and contain a minimum of a bench or other seating, tree, planter, fountain, kiosk, bike rack, or artwork for each 200 square feet of area. (d) Façade articulation. Employ at least two of the following select optional articulation features from TMC § 13.06.100D.4.a(2) as listed below. These features may be different or repeated to meet this requirement. • | Minor vertical building modulation. Minimum depth and width of modulation is two feet and four feet, respectively, if tied to a change in building material/siding style and/or roofline modulation. • | Major vertical building modulation. Minimum depth and width of modulation is 10 and 15 feet, respectively. • | Horizontal modulation (upper level stepbacks). Provide a minimum horizontal modulation of five feet from the building face for at least 75 percent of the facade. • | Roofline modulation consistent with TMC § 13.06.100D.4.c(3). • | Balconies. To qualify, balconies must be recessed at least 18 inches beyond the primary building face. Example FiguresDiagram depicting horizontal modulation. [image] Articulation examples of mixed-use buildings containing residential uses on upper floors. These examples include vertical and horizontal modulation and changes in building materials at no more than 30-foot articulation intervals. [image] Examples of façades that effectively use techniques to reduce the apparent bulk and scale of the structure. The image on the left uses street and upper level courtyards whereas the right image uses both vertical building modulation and the use of contrasting building materials and articulation. [image] c. Light and air access for residential units. Every residential unit shall have access to a minimum amount of light, direct or indirect, and air per these requirements. This requirement applies to the lower 10 stories of buildings in all districts. Floors over 10 are exempt from these requirements. For the purposes of applying this requirement, floor heights are counted from the street-facing façade containing the Primary Entrance. Units that face a side or rear property line or an internal exterior space shall provide sufficient separation as follows. Units that directly face a street, alley, or other public rights-of-way, or land determined to be undevelopable are exempt. (1) Units that only face a side or rear property line shall be set back from the property line at least eight feet for a width of at least 10 feet. (2) Units that only face an internal exterior space, such as a courtyard or light well, shall be no closer than 15 feet from any parallel wall. (3) Units that face a side or rear property line and an internal exterior space is required to only meet subsection D.4.c(1) or (2) above. (4) Every unit shall be afforded at least 10 feet of total exterior wall width and each shall include at least one operable window. (5) Private amenity spaces, such as balconies, may encroach up to five feet into this space. Example FiguresExamples of buildings that meet minimum light and air standards for residential units. [image] d. Roofline design. (1) General requirements. • | Buildings employing a flat roof must meet the standards in TMC § 13.06.100B.4.c(2). • | The length of any continuous roofline visible from a street, open space, or associated parking lot shall that extends more than 100 feet shall employ roofline modulation consistent with the standards described below. • | Buildings employing roofline modulation for the purposes of satisfying TMC § 13.06.100B.4.a(2)(e) shall be consistent with the roofline modulation standards described below. (2) Flat roof standards. Buildings or portions thereof featuring flat roofs (horizontal roofs with either no slope or only a slope sufficient to effect drainage, often which incorporate surrounding parapets) shall employ roofline treatments incorporating one or more of the following design elements along façades facing a street. (a) A cornice of two parts with the top projecting at least 6 inches from the face of the building and at least 2 inches further from the face of the building than the bottom part of the cornice. The height of the cornice shall be at least 12-inches high for buildings 10 feet or less in height; 18 inches for buildings greater than 10 feet and less than 30 feet in height; and 24-inches for buildings 30 feet and greater in height. The cornice must extend along at least 75 percent of the façade. (b) Use of balcony/deck railings that function as a roofline treatment. Such railings must be at least 2 feet in height and extend along at least 75 percent of the façade and shall be visible from the adjacent street centerline. (c) Use of contrasting building materials on the top floor or top two floors for buildings five stories or taller, for at least 75 percent of the façade. (3) Roofline modulation. Roofline modulation is not required of all buildings. However, where required or otherwise applied, the roofline shall meet the following modulation requirements. Whether the roof is flat or pitched, roofline modulation can be accomplished through either vertical or horizontal roofline articulation or a combination of both that breaks up the dominant roof form to enhance visual interest. (a) Vertical articulation can be achieved by incorporating any vertically-oriented change to the roofline. This can include stepped parapets, dormer, gables, domes, turrets or other projecting elements. The minimum vertical dimension of roofline modulation is 2 feet when combined with vertical building modulation of or 4 feet when it is not. (b) Horizontal articulation can be achieved by incorporating a horizontally-oriented change to the roofline. This can include recessing the peak of the roofline from the building face with a pitched roof, vertical building modulation, or other methods that provide horizontal changes within the roof form. If vertical building modulation is to be used to provide horizontal roofline modulation, the building modulation shall meet the minimum requirements of TMC § 13.06.100B.4.a(2) or 13.06.100B.4.b(1)(b). (c) Modulating elements shall equal a minimum of 15 percent of each elevation’s roofline. (4) Roofline elements shall not project over property lines, except where permitted on property lines abutting public right-of-way. e. Historic resources. Applicability: New or substantially altered development adjacent to structures or districts that are designated historic within the Downtown Residential (DR) district. (1) General requirements. The design shall make use of similar attributes such as massing, roofline, setbacks from the property lines, window types, and materials to ensure visual continuity between the older and the newer development and be subject to the approval of the Historic Preservation Officer. E. Single, two and three-unit dwelling minimum design standards in non-Urban Residential Zones. 1. Applicability. The following requirements apply to all single, two, and three-unit dwellings in all districts except Urban Residential. a. Single-unit dwellings legally established prior to August 1, 2011 are exempt from these standards. However, remodels and additions to such single-unit dwellings shall not increase the level of nonconformity. 2. Purpose. The following standards are intended to promote pedestrian access, compatibility with residential neighborhoods, building orientation to the street, and to minimize the impacts of vehicular access. 3. Main building orientation. All dwellings shall maintain primary orientation to the adjacent street or right-of-way and not toward the alley or rear of the site, unless otherwise determined by the Director. The building elevation facing the street or right-of-way shall not contain elements commonly associated with a rear elevation appearance. 4. Entries. Covered entries are required for each common entry or individual dwelling unit entry with minimum dimensions of 4 feet by 6 feet. 5. Windows and openings. At least 15 percent of the street-facing façades (all vertical surfaces facing the street) shall be comprised of transparent windows and/or doors. Rough openings are used to calculate this requirement. 6. Garage design standards. a. Vehicular access and garages for all units shall be placed off of the alley, where suitable access, such as an abutting right-of-way that is or can be developed, is available. b. For garages that include vehicular doors facing the front or corner street property line, the building or portion of the building with such doors shall be setback at least 20 feet from the front or corner street property line or private road easement. c. The garage face or side wall shall occupy no more than 50 percent of the length of a ground-level façade facing a street. d. Where the garage faces the side, but is visible from the frontage, the garage shall incorporate a window on the front-facing façade so that it appears to be a habitable portion of the building. The window size and design must be compatible with the windows on habitable portions of the dwelling. e. Driveway approaches shall also be consistent with the standards in Section 13.06.090C. [image] 7. Corner duplexes (two-unit dwellings). Duplexes located on corner lots shall be designed with pedestrian entries located on opposite street frontages so that the structure appears to be a single-unit dwelling from each street, or with a single shared entrance that presents the appearance of one single-unit house. Where no alley is available for vehicular access, separate driveways for each unit may be placed on opposite streets. 8. Articulation. Duplexes and triplexes shall be articulated to either look like two or three distinct dwelling units from the street or to look like one dwelling. Specifically: a. Buildings articulated to look like distinct dwelling units shall include individual covered entries plus one of the following: (1) Roofline modulation to distinguish one unit from another (or the appearance of separate units) as viewed from the street; or (2) Vertical building modulation to help distinguish between the different units in the building. The minimum depth and width of modulation shall be 2 and 4 feet, respectively, if tied to a change in building material/siding style. Otherwise, the minimum depth and width of modulation shall be 10 and 15 feet, respectively. b. Buildings designed to look like one large dwelling shall feature only one entrance visible from the street. This could be a common entrance for all units, or the entrances for additional units could be provided at the side or rear of the building. 9. Façade variety. Single-unit detached dwellings shall not use front façades that are duplicative with adjacent single-unit detached dwellings. In order to qualify as a different façade elevation, dwellings shall have different roofline configurations and different entry/porch designs. Simple reverse configurations of the same façade elevation on adjacent lots are not sufficient to meet this requirement. In addition, a minimum of two of the following alternatives shall be utilized: a. Different window opening locations and designs, b. One and two–story dwellings, c. Different exterior finish materials and finishes, or d. Different garage location, configuration and design. 10. Utilities. a. Utility meters, electrical conduit, and other service utility apparatus shall be located and/or designed to minimize their visibility from the street. If such elements are mounted in a location visible from the street, common open space, or shared auto courtyards, they shall be screened with vegetation or by architectural features. b. Service, loading, and garbage areas. Developments shall provide a designated area for service elements (refuse and disposal). Such elements shall be sited along the alley, where available. Such elements shall not be located along the street frontage. Where there is no alley available, service elements shall be located to minimize the negative visual, noise, odor, and physical impacts and shall be screened from view from the street and sidewalk. F. Urban Residential (UR) minimum design standards. 1. General applicability. The Housing Type Standards and Additional Standards (together called design standards) of this section are required to implement the urban design goals of the Comprehensive Plan of the City of Tacoma. The design standards apply to all new development in the Urban Residential (UR) districts as outlined below, except as follows: a. Standards. Each item of this section shall be addressed individually. Exceptions and exemptions noted for specific development situations apply only to the item noted. b. Alterations. (1) Three thresholds are used to gauge the extent of design standard compliance on alterations to existing development: Level I alterations include all remodels and/or additions within a two-year period whose cumulative value is less than 50% of the value of existing development or structures, as determined by the applicable Building Code. The requirement for such alterations is only that the proposed improvements meet the standards and do not lead to further nonconformance with the standards. For example, if a property owner decides to replace a building façade's siding, then the siding shall meet the applicable exterior building material standards, but elements such as building modulation would not be required. Level II alterations include all remodels and/or additions within a two-year period whose cumulative value ranges from 50% to 200% of the value of the existing development or structure, as determined by the applicable Building Code. All standards that do not involve repositioning the building or reconfiguring site development shall apply to Level II alterations. Level III alterations include all remodels and/or additions within a two-year period whose cumulative value exceeds 200% of the value of the existing development or structure, as determined by the applicable Building Code. Such alterations shall conform to ALL standards. (2) The standards do not apply to remodels that do not change the exterior form of the building. However, if a project involves both exterior and interior improvements, then the project valuation shall include both exterior and interior improvements. (3) No addition or remodel shall increase the level of nonconformity or create new nonconformities to the development or design standards. c. Temporary. Temporary structures are exempt from the design standards of this section. d. Historic. Refer to TMC Chapter 13.07 (Landmarks and Historic Special Review Districts) for applicable standards for entries and other building elements in Historic Districts. When conflicts in the code exist, Historic Standards take priority over Building Design Standards. e. Religious assembly facilities which can demonstrate that the design standards impose a substantial burden, administratively or financially, on their free exercise of religion, shall be exempt from compliance. f. Adaptive reuse of heritage building. Refer to TMC §§ 13.05.010A.6 and 13.06.080T.3, as applicable, for standards for adaptive reuse of heritage buildings. 2. Relationship to other standards. These Design Standards work together with the other code sections to regulate buildings, open space, trees, parking and other elements on a site. Standards in one section are not repeated in another section. Refer to the following sections for other standards applicable to lots within the Urban Residential (UR) Districts: a. TMC § 13.06.020F District Development Standards and Table: Housing types allowed, Uses permitted, Lot area & measurements, Density, Floor Area Ratio, Maximum height, Number of stories, Setbacks, Building separation, Floor area ratio, Amenity space. b. TMC § 13.06.090 Site Development Standards: Landscaping standards, Off-street parking areas, Pedestrian and bicycle support standards, Fences and retaining walls, Utilities, Street level building transitions. 3. Determining applicable housing type building design standards. a. When applying for a permit, the applicant must indicate which Housing Type is being proposed, and must comply with Building Design Standards for that type. b. Multiple buildings and different housing types may be combined on a site, especially on large sites. These are often, but not always, platted for separate ownership. Backyard Buildings, by definition, are anticipated behind many of the other housing types. When combining housing types on a site, the applicable Housing Standards will be applied individually to each portion of the site as appropriate and indicated on the permit application. In no case shall the maximum density standards for a site be exceeded. c. Limited mixed-use residential. Buildings shall conform to the housing type design standards most similar to the proposed development based on the housing types' distinguishing factors such as dwelling unit number, arrangement, and relationship to the street. 4. Refer to TMC Chapter 13.07 (Landmarks and Historic Special Review Districts) for applicable standards for entries and other building elements in Historic Districts. When conflicts in the code exist, Historic Standards take priority over Building Design Standards. 5. Overview. a. Description. Walkable, vibrant, inclusive and healthy residential neighborhoods are often made up of a variety of “Middle Housing” types that provide different building, yard and dwelling unit configurations to meet a variety of living preferences, family sizes and budgets. Middle Housing neighborhoods can also promote pedestrian access, compatibility with existing residential neighborhoods, building orientation to the street, and minimize the impacts of vehicular access. These Building Design Standards for the Urban Residential (UR) districts illustrate a number of housing types to provide both the predictability and variety of successful Middle Housing neighborhoods. Housing Types Key [image] 6. Housing type standards. a. Houseplex – House, Duplex, Triplex, 4-plex, 5-plex, 6-plex. * Refer also to Additional Standards TMC § 13.06.100F.4. (1) Description. A single building containing 1 to 6 units, which may be in a “side-by-side” or “stocked configuration. At least one private or shored entry is required from the street, and a private or shored yard is often included behind the building. Multi-story units that ore oriented perpendicular to the street and where vehicular and/or pedestrian access is provided from a shored facility along the side (often called "”slot homes”) ore included in this type. (2) Applicability. The following requirements apply to all Houseplex dwellings in all Urban Residential districts, as well as to new units added to or built within existing houses. The total number of units per lot is subject to District Development Standards density maximums. (3) Purpose. Houseplexes ore intended to continue the existing pattern of lowscale neighborhoods with detached homes along the street, generous backyards, as well as sideyards creating a rhythm of light and air between buildings. This housing type enables "house scaled" structures with higher densities that allow more people to enjoy a traditional house and yard arrangement. Character examples for Houseplexes [image] Houseplex - House, Duplex, Triplex, 4-plex, 5-plex, 6-plex Design Standards [image] [image] Figures: Houseplex Design Standards (4) Building placement. (A) Building orientation*: Must have primary orientation to street. Corner buildings may orient to two streets. (B) Setbacks: Refer to District Standards, TMC § 13.06.020F. (C) Separation between buildings on same site: • | 10’ • | 6’ if building height of both buildings is less than 25’ or existing tree is retained. (5) Access and parking. (D) Pedestrian access. Primary entry: • | One entry required at primary street. • | Additional Entries: Allowed from street, side yard, or rear yard. Sidewalk or pedestrian path required from the street. (E) Parking. • | Required access from an alley if exists unless the alley is not practically available (TMC § 13.06.090C.14) or the site meets the Incentives for Ownership Opportunities (TMC § 13.06.020F.4) or Incentives for Accessory Dwelling Units (TMC § 13.06.020F.5). • | Prohibited between building and street. • | Prohibited within front setback (except in front of garages). Garages must be setback 20' from lot line. • | Refer to Site Development Standards (TMC § 13.06.090C for vehicle, and § 13.06.090G for bike parking ratios). (F) Driveway. • | Max number: 1 per 12,000 SF of lot area. • | Limited to access from alley if exists unless the alley is not practically available (TMC § 13.06.090C.14) or the site meets the Incentives for Ownership Opportunities (TMC § 13.06.020F.4) or Incentives for Accessory Dwelling Units (TMC § 13.06.020F.5). • | Refer to Site Development standards TMC § 13.06.090C (G) Habitable space*. • | 10' deep along 75 percent of street-facing facades. (6) Building size. (H) Building width. • | UR-1 and UR-2: 50' max • | UR-3: 75' max (I) Building depth. • | UR-1 and UR-2: 75' max • | UR-3: 90' max (J) Height limits: Refer to District Standards, TMC § 13.06.020F. (7) Building articulation. (K) Covered entry*. • | Covered entries required: 3’ deep min. • | Single unit entry: 20 sf min • | Shared entry: 30 sf min (L) Transparency/Windows and openings*. • | 15% transparent to street • | 10% transparent to alleys, shared open space, and surface parking courts • | Non-residential uses: 25% transparency between 2' to 10' above sidewalk grade (M) Articulation*. Street-facing façades may be articulated to look like a single dwelling or to emphasize distinct dwelling units; one feature required for façades over 40' wide. Two features required for façades over 60' wide. (8) Open space. (N) Amenity space*. Private, common, or mix. Refer to District Standards, TMC § 13.06.020F. (O) Tree credit. Refer to District Standards, TMC § 13.06.020F. b. Backyard building. *Refer also to Additional Standards TMC § 13.06.100F.4. (1) Description. A building located behind another structure at the rear of a lot. The building may contain a garage. The building may be accessed from a shared or private path from the front sidewalk or from a secondary street on a corner lot. A small yard and parking space can be included. This housing type can include detached accessory dwelling units (DADU), but also includes any structure containing no more than six units. (2) Applicability. The following standards apply to all Backyard Buildings in all Urban Residential districts. The total number of units per lot is subject to District Development Standards density maximums. (3) Purpose. Backyard Buildings are intended to create additional housing on infill lots, while maintaining neighborhood character and promoting retention of existing buildings, with “gentle density” that is less visible from the street. Backyard buildings can provide homeowners with a means to provide for companionship and security nearby, and they can also contribute to neighborhood stability and protect property values by creating avenues for additional income, aging in place, and the meeting of personal and property needs. With smaller footprints, these buildings can also be lower cost units that are more affordable to low- and moderate-income people. Character examples for Backyard Buildings [image] [image] [image] [image] Backyard Building Design Standards [image] [image] Figures: Backyard building design standards (4) Building placement. (A) Building orientation*. May orient to a backyard, alley, or a street on a corner lot based on site conditions. (B) Setbacks. 0’ rear and side setback from alley. Refer to District Standards, TMC § 13.06.020F. (C) Separation between buildings on same site. • | 10’ • | 6’ if building height of both buildings is less than 25’ or existing tree is retained. (5) Access and parking. (D) Pedestrian access. Sidewalk or pedestrian path required from street. (E) Parking. Limited to access from an alley or existing driveway if exists. Prohibited between building and street. Prohibited within front setback. Garage doors must be setback 20’ from lot lines abutting streets. Refer to Site Development Standards (TMC § 13.06.090C for vehicle and TMC § 13.06.090G for bike parking ratios). (F) Driveway. Max number: 1 per 12,000 SF of lot area shared with street-facing buildings. Required to be shared with driveways serving street-facing buildings, or must occur from alley if one exists unless the alley is not practically available (TMC § 13.06.090C.14) or the site meets the Incentives for Ownership Opportunities (TMC § 13.06.020F.4) or Incentives for Accessory Dwelling Units (TMC § 13.06.020F.5). Refer to Site Development Standards TMC § 13.06.090C. (G) Habitable space*. Not applicable. (6) Building size. (H) Building width. • | UR-1 and UR-2: 40' max. • | UR-3: 75' max. (I) Building depth. 40' max. (J) Height limits. Refer to District Standards, TMC § 13.06.020F. (7) Building articulation. (K) Covered entry*. Covered entries required: • | 3' deep min. • | Single unit entry: 20 SF min. • | Shared entry: 30 SF min. (L) Transparency/Windows & openings*. • | 15% transparent to street if one exists. • | 10% transparent to alleys. Placement should endeavor to provide privacy from adjacent units. • | Non-residential uses: 25% transparency between 2' to 10' above sidewalk grade (M) Articulation*. Not applicable. (8) Open space. (N) Amenity space*. Private, common or mix. Refer to District Standards, TMC § 13.06.020F. (O) Tree credit. Refer to District Standards, TMC § 13.06.020F. c. Courtyard housing. * Refer also to Additional Standards TMC § 13.06.100F.4. (1) Description. A group of buildings or units arranged around a shared courtyard. Depending on the zone, units may be detached or attached. The courtyard is entered from the street, provides pedestrian access to the units, and is a shared social space which takes the place of private back yards. Detached buildings within Courtyard Housing developments may include up to six dwelling units per building. (2) Applicability. The following standards apply to Courtyard Housing developments in all Urban Residential districts where allowed. The total number of units per lot is subject to District Development Standards density maximums. (3) Purpose. Courtyard housing offers an alternative spatial arrangement, while fitting the scale and adjacency to open spaces enjoyed in detached housing neighborhoods. The courts can contribute aesthetically to the street, or provide social spaces that foster children’s play. The central courts allow residents to look in on each other occasionally, or to organize into semi-communal “co-housing” arrangements. Character examples for Courtyard Housing [image] Courtyard Housing Design Standards [image] Figures: Courtyard Housing Design Standards (4) Building placement. (A) Orientation*. Buildings along a street must have primary orientation to the street. Internal buildings must orient to courtyard. (B) Setbacks. 0’ Rear Setback from alley when parking is provided directly from alley. Refer to District Standards, TMC § 13.06.020F. (C) Separation between buildings on same site: • | 10' • | 6' if building height of both buildings is less than 25' or existing tree is retained. (5) Access and parking. (D) Pedestrian access. Entry from common courtyard to each building and/or unit; entry from street ok at front units. (E) Parking. Required access from an alley if exists unless the alley is not practically available (TMC § 13.06.090C.14) or the site meets the Incentives for Ownership Opportunities (TMC § 13.06.020F.4) or Incentives for Accessory Dwelling Units (TMC § 13.06.020F.5). Prohibited between building and street. Prohibited within front setback. Garages must be setback 20' from lot line. Refer to Site Development Standards, TMC § 13.06.090C for vehicle and TMC § 13.06.090G for bike parking ratios. (F) Driveway. Max number. 1 per 12,000 SF of lot area. Limited to access from alley if exists unless the alley is not practically available (TMC § 13.06.090C.14) or the site meets the Incentives for Ownership Opportunities (TMC § 13.06.020F.4) or Incentives for Accessory Dwelling Units (TMC § 13.06.020F.5). Refer to Site Development Standards, TMC § 13.06.090C. (G) Habitable space*. 10’ deep along 75% of street-facing facades. (6) Building size. (H) Building width: 40’ max for a detached building or the wing of an attached building. (I) Building depth: Not applicable. (J) Height limits: Refer to District Standards, TMC § 13.06.020F. (7) Building articulation. (K) Covered entry*. Covered entries required: • | 3' deep min. • | Single unit entry: 20 SF min. • | Shared entry: 30 SF min. (L) Transparency/Windows & openings*. • | 15% transparent to street and courtyard. • | 10% transparent to alleys and surface parking lots. • | Non-residential uses: 25% transparency between 2' to 10' above sidewalk grade. (M) Articulation*. Not applicable. (8) Open space. (N) Amenity space*. Shared courtyard required. Min width: 20'. Refer to District Standards, TMC § 13.06.020F. (O) Tree credit. Refer to District Standards, TMC § 13.06.020F. d. Rowhouse. (1) Description. Typically a multi-story building with access to the street from its front door. Each Rowhouse may contain more than one unit accessed from the same sidewalk and front door. A Rowhouse is always attached to two to five other Rowhouses, which together create a “Rowhouse Cluster” of three to six Rowhouses. (2) Applicability. The following requirements apply to all Rowhouse dwellings in all Urban Residential districts. The total number of units per lot is subject to District Development Standards density maximums. (3) Purpose. Rowhouses are intended to provide housing at a scale between detached housing and multiplexes. With immediate street access to the units, this housing type can work well for families. Often provided for sale, they can create home ownership opportunities, and usually at a lower cost than detached houses because the buildings are connected and on smaller lots. Character examples for Rowhouses [image] Rowhouse Design Standards [image] Figures: Rowhouse Design Standards. (4) Building placement. (A) Building orientation*: Must have primary orientation to street; Rowhouse Clusters on corner lots may choose to orient to two streets. (B) Setbacks: Refer to District Standards, TMC § 13.06.020F, which measure to Rowhouse Clusters. (C) Separation between buildings on same site: • | 0’ between Rowhouses • | 10’ between each Rowhouse Cluster • | 6’ if building height of both buildings is less than 25’ or existing tree is retained. (5) Access and parking. (D) Pedestrian access. Individual access via a sidewalk or pedestrian path is required to each Rowhouse from the street. Rowhouses on corner lots may select which street to orient to. (E) Parking. Required access from an alley if exists unless the alley is not practically available (TMC § 13.06.090C.14) or the site meets the Incentives for Ownership Opportunities (TMC § 13.06.020F.4) or Incentives for Accessory Dwelling Units (TMC § 13.06.020F.5). Prohibited between building and street. Prohibited within front setback. Garages prohibited on front facades. Garages must be setback 20' from lot line. Refer to Site Development Standards, TMC § 13.06.090C for vehicle and TMC § 13.06.090G for bike parking ratios. (F) Driveway. Max number: 1 per 12,000 SF of lot area. Rowhouse Clusters must share a driveway if parking from alley is not available. Limited to access from alley if exists unless the alley is not practically available (TMC § 13.06.090C.14) or the site meets the Incentives for Ownership Opportunities (TMC § 13.06.020F.4) or Incentives for Accessory Dwelling Units (TMC § 13.06.020F.5). Refer to Site Development Standards, TMC § 13.06.090C. (G) Habitable space*. 10’ deep along 75% of street-facing facades. (6) Building size. (H) Building width. UR-1 and UR-2: 75' max, 40' min (for each Rowhouse Cluster). UR-3: 90' max, 40' min (for each Rowhouse Cluster) (I) Building depth. UR-1 and UR-2: 60' max. UR-3: 80' max (J) Height limits. Refer to District Standards, TMC § 13.06.020F. (7) Building articulation. (K) Covered entry*. Covered entries required: • | 3’ deep min • | Single unit entry: 20 SF min • | Shared entry: 30 SF min • | Non-residential uses: 25% transparency between 2' to 10' above sidewalk grade (L) Transparency/Windows & openings*. • | 15% transparent to streets, • | 10% transparent to alleys, shared open space, and parking drives or lots (M) Articulation*. Street-facing facades must be articulated to emphasize each individual Rowhouse using at least one Articulation Feature. (8) Open space. (N) Amenity space*. Private. Common open space of the same area is allowed. Refer to District Standards, TMC § 13.06.020F. (O) Tree credit. Refer to District Standards, TMC § 13.06.020F. e. Multiplex. * Refer also to Additional Standards TMC § 13.06.100F.4 at the end of this chapter. (1) Description. A building consisting of 7 or more stacked units, with the appearance of a large house or a small apartment building. Access is often from one shared entry at the street leading to a central corridor accessing all units, but other configurations are possible (including a few single-stair buildings connected together). (2) Applicability. The following standards apply to Multiplex developments in all Urban Residential district. The total number of units per lot is subject to District Development Standards density maximums. Refer to Tacoma Municipal Code Section 13.06.100 C. for multi-unit developments in other zones. (3) Purpose. Multiplexes are intended to provide housing at an intermediate scale between detached houses and the larger apartments buildings in mixed use centers. Located nearer transit and anticipated to contain smaller units, they can provide naturally occurring affordable housing. Character examples for Multiplexes [image] Multiplex Design Standards [image] (4) Building placement. (A) Building orientation*. Must have primary orientation to street. (B) Setbacks. Refer to District Standards, TMC § 13.06.020F. (C) Separation between buildings on same site. • | 10’ • | 6’ if building height of both buildings is less than 25’ or existing tree is retained. (5) Access and parking. (D) Pedestrian access. At least one shared entry to the building is required from the street within 15' of the sidewalk. Individual entries to ground floor units are permitted. (E) Parking. Required access from an alley if exists unless the alley is not practically available (TMC § 13.06.090C.14) or the site meets the Incentives for Ownership Opportunities (TMC § 13.06.020F.4) or Incentives for Accessory Dwelling Units (TMC § 13.06.020F.5). Prohibited between building and street. Prohibited within front setback. Garages must be setback 20' from lot line. Refer to Site Development Standards, TMC § 13.06.090C for vehicle and TMC § 13.06.090G for bike parking ratios. (F) Driveway. Max number: 1 per 12,000 SF of lot area. Limited to access from alley if exists unless the alley is not practically available (TMC § 13.06.090C.14) or the site meets the Incentives for Ownership Opportunities (TMC § 13.06.020F.4) or Incentives for Accessory Dwelling Units (TMC § 13.06.020F.5). Refer to Site Development Standards, TMC § 13.06.090C. (G) Habitable space*. 10' deep along 75% of street-facing facades. (6) Building size. (H) Building width. 90’ max. (I) Building depth. 100’ max. (J) Height limits. Refer to District Standards, TMC § 13.06.020F. (7) Building articulation. (K) Covered entry*. Covered entries required: • | 3' deep min • | Single unit entry: 20 SF min • | Shared entry: 30 SF min (L) Transparency/Windows & openings*. • | 15% transparent to street. • | 10% transparent to alleys, shared open space, and surface parking lots. • | Non-residential uses: 25% transparency between 2' to 10' above sidewalk grade. (M) Articulation*. Required for street facing facades: One feature for facades up to 60’ wide. Two features for facades over 60’ wide. (8) Open space. (N) Amenity space*. Private amenity space may count for no more than 25% of total required. Refer to District Standards, TMC § 13.06.020F. (O) Tree credit. Refer to District Standards, TMC § 13.06.020F. 7. Additional building design standards. a. Building orientation. (1) A building shall have a front elevation with a primary entrance oriented to the adjacent street, right of way, or other space required by the Housing Type. Front setbacks are calculated to this front elevation, and Building Width is measured along this elevation. Refer to Habitable Space requirements required at the primary building elevation. (2) Other building entries are allowed on other building facades in addition to the required entry on the front elevation. (3) This front elevation and all street-facing facades shall not contain elements commonly associated with a rear elevation appearance, such as utility meters, refuse containers, loading docks, and/or dumpsters. b. Habitable space. (1) Purpose. To promote active, welcoming, neighborly activities along streets and sidewalks. (2) Spaces include: residential spaces such as foyers, entries, living rooms, dining rooms, kitchens, bedrooms, dens, lofts, home offices, common amenity spaces, playrooms, and mudrooms, as well as shared ancillary spaces such as lobbies, mailrooms, and bicycle storage rooms. Also includes the active portions of permitted or conditionally permitted non-residential uses per TMC § 13.06.020E. Excludes spaces such as garages, storage spaces, loading, mechanical, electrical, or other utility rooms. (3) Location. The floor of a Habitable Space must be within 5 feet of sidewalk grade elevation, unless site conditions prohibit such a relationship. This is to allow garages or other utility spaces to be located partially underground along the street-frontage without counting against the Habitable Space requirements. c. Articulation features. (1) Applicability. As required in Building Design Standards for Houseplexes, Rowhouses and Multiplexes. (2) Required articulation features. These may combined: (a) Modulation. (i) Articulating a building’s roofline. May include sloping, stepping back or forward, a strong cornice line, or an expressive overhang. (ii) Articulating a building’s top to contrast and complement its lower levels. May include upper level stepbacks (provided the top of the building is visible from the centerline of the adjacent street), and/or façade and window features below. (iii) Articulating a building’s base to contrast and complement its upper levels. May include a change of plane at least 2 feet deep, and/or façade and window features below. (iv) Articulating a building’s elevation. May include vertical changes of plane at least 2 feet deep, and/or façade and window features below. (v) Repeated stoops at least 3 feet above sidewalk grade to individual units. (b) Facades and windows. (i) Significant changes of cladding material. (ii) Real brick used as the cladding material on a majority of the façade. (iii) Repeated balconies or bay windows. Maximum spacing of 16 feet. (iv) Windows with deep or detailed frames. May include windows recessed at least 2.5 inches from the cladding material, decorative window trim, or deep metal “flashing” surrounds. d. Transparency/Windows & openings. (1) Vertical façade surfaces facing a street, alley, courtyard, plaza, drive aisle, parking court, or surface parking lot shall incorporate transparent doors and windows equal to the amount required by the Housing Type. Rough openings are used to calculate this requirement. Windows in garage doors or walls do count toward meeting this standard. (2) Unscreened, flat, blank walls on the first story more than 25 feet in width are prohibited facing a public street and/or highway right-of-way, residential zone, or parking lot. These walls shall use modulation, windows, openings, landscaping to achieve the required visual break. The visual break shall be at least 1 foot in width. Items provided for other requirements may satisfy this requirement as appropriate. Stored merchandise, pipes, conduit, utility boxes, air vents, and/or similar equipment do not count toward this requirement. (3) Placement of windows on facades facing neighboring buildings, or units or buildings on the same lot, shall endeavor to create appropriate levels of privacy between neighbors. e. Covered entries. (1) Applicability: Covered entries are required for primary entries to buildings and units. They are not required for additional entries such as side doors or back doors. (2) May include: porches, canopies, alcoves beneath upper story overhangs, and other elements or combinations that protect pedestrians from the weather. (3) May be included as part of Amenity Space requirement. (4) Awnings made of canvas or non-permanent construction do not count towards meeting this requirement. (5) Refer to TMC § 13.05.040 for porch requirements in Historic Districts. f. Amenity space. (1) All units shall have access to either private or common amenity space. (2) Private amenity space: This includes ground-related spaces such as yards, patios, gardens, and decks. Requirements include the following: • | No dimension shall be less than 7 feet. • | Must be directly accessible from the dwelling unit. • | May also be provided as balconies or porches of at least 50 SF, and no dimension less than 5 feet. (3) Common amenity space: This includes ground-related spaces such as yards, patios, courtyards, decks, community gardens, children’s play areas, or other multi-purpose outdoor recreational and/or green spaces. Requirements include the following: • | No dimension shall be less than 7 feet. • | Must be positioned near a shared path, shared building entry, or other pedestrian activity. • | Must feature paths, appropriate hard surfacing, landscaping, seating, lighting and other pedestrian amenities to make the area functional and enjoyable. • | Should be oriented to receive direct sunlight for part of the day, facing east, west, or (preferably) south, when possible. • | Must be open to the sky, except a maximum of 25% of the common amenity space may be covered but not enclosed by porches, gazebos, pergolas, or other such structures, provided no dimension is less than 8 feet. (4) Rooftop decks may be used to meet up to 50% of the Amenity Space requirements if they include the same minimum dimensions and amenities required of ground-related amenity space. (5) Landscaping: Up to 35% of the amenity space may be comprised of landscaping. Tree canopy may overlap any amount of amenity space. Refer to Landscaping Standards TMC § 13.06.090B. (6) Vehicular access areas shall not count as amenity space. g. Corner sites. (1) Applicable to sites with two or more street frontages. On non-alley sites, an applicant may choose which street to use as the primary street for the purposes of determining Building Orientation, and Building Width and Depth. (2) Garages are only allowed within the rear portion of corner lot, at least 70’ from the front property line, unless directed otherwise by City engineer. (3) Backyard Buildings and Courtyard Housing on corner lots may have primary or secondary pedestrian entries accessed from the secondary street. Secondary pedestrian entries are also encouraged in other Housing Types. (4) Standards for Windows & Openings apply to both street-facing facades on corner lots. h. Large sites. (1) Applicable to sites 60,000 SF or larger. (2) Connectivity: Must meet the connectivity standards in TMC § 13.06.090F. Pedestrian and Bicycle support standards. (3) Standards: Large Sites must comply with District Standards, Building Design Standards, and Site Design Standards, with the following exceptions: (a) When complying with Housing Type Building Design Standards for 4. Building Placement and 5. Access & Parking, the following connections may be used in place of Streets: (i) Though-Block Connections. (ii) Interior Access Roads. (iii) Walkways, Pathways. (iv) Pedestrian Connections 10’ or wider. (b) Backyard buildings: One row of Backyard Buildings is allowed behind each street-fronting Houseplexes, Rowhouses or Multiplexes. (4) Nonconforming large sites permitted before (March 2024) may allow renovations and additions to existing buildings. i. Addressing. All buildings must have clear addressing visible from the street. If Backyard Buildings or any Courtyard Housing buildings are not visible from the street, an address and some form of directional notation must located be along a walkway, on a fence, on a front building, or in some location that differentiates the front building address from the rear building address and is visible from the main access point to the property. G. Townhouse minimum design standards. 1. Applicability. The following requirements apply to all townhouse dwellings in all districts except for Urban Residential (UR) districts. 2. Purpose. The following standards are intended to implement the urban form, housing and aesthetic goals of the Comprehensive Plan by providing façade articulation that emphasizes individual units and reduces the apparent mass of structures, minimizing impacts of vehicular access and service elements, and emphasizing pedestrian access and building orientation to the street. 3. Building mass. a. The maximum number of units in one building is six, with minimum spacing between buildings of 10 feet. b. Unit articulation. Façades with more than two townhouses facing a street, alley, common open space or common parking area shall be articulated to emphasize individual units. This can be accomplished by either roofline modulation and/or vertical building modulation. To qualify for vertical building modulation, the minimum depth and width of modulation shall be 2 and 4 feet, respectively, if tied to a change in building material/siding style. Otherwise, the minimum depth and width of modulation shall be 10 and 15 feet, respectively. [image] 4. Garage orientation & vehicular access. a. Garages shall not face any street if vehicular access is available from an alley. b. Vehicular access and garages for all units shall be placed off of the alley, where suitable access, such as abutting right-of-way that is or can be developed, is available. c. Where street-front vehicular access is necessary, driveway approaches shall be limited to no more than one for every 9 units in the development. d. Driveway approaches shall also be consistent with the standards in Section 13.06.090C. 5. Pedestrian orientation. a. Non X-Districts. (1) All dwellings shall maintain primary orientation to the adjacent street or right-of-way and not toward the alley or rear of the site, unless otherwise determined by the Director. (2) Townhouses must have an individual entry that faces and is accessible from the street/sidewalk. Townhouses on corner lots only need to provide such an entry to one of the two adjacent streets/sidewalks. (3) The building elevation facing the street or right-of-way shall not contain elements commonly associated with a rear elevation appearance, such as loading docks, utility meters, and/or dumpsters. b. In designated centers. (1) All townhouses on lots with street frontage must maintain primary orientation to the adjacent street or right-of-way and have an individual entry that faces and is accessible from the street/sidewalk. Townhouses on corner lots only need to provide such an entry to one of the two adjacent streets/sidewalks. (2) In the case of townhouse buildings that include units without street frontage, such as a mid-block site with a building that is perpendicular to the street, the townhouse unit abutting the street must include an individual entry facing the street, a porch or covered entryway, and other architectural features associated with the front elevation appearance. (3) Building elevations facing the street or right-of-way shall not contain elements commonly associated with a rear elevation appearance. Any area between the front façade and the sidewalk/right-of-way shall be improved with landscaping, seating or yard space, a front porch, or similar features. (4) Townhouse units with access exclusively from a drive aisle/court shall provide architectural features typically associated with the front elevation along the elevation facing the drive aisle/court. At least 10 percent of the façade (all vertical surfaces facing the drive aisle/court) shall be comprised of transparent windows and/or doors. Rough openings are used to calculate this requirement. (5) Townhouses with front doors facing alleys shall not be permitted unless the following requirements are met: The vehicular surface shall be paved through the entire block length; a continuous sidewalk shall be constructed on one side connecting to abutting public sidewalks; and street trees shall be planted along one side along the entire length of the alley. (6) A continuous pedestrian walkway, which can be a shared walkway, must be provided between the front entrance of each unit and the nearest public sidewalk. In the case of corner lots, at least one walkway shall connect to both sidewalks/rights-of-way unless infeasible due to topography. Walkways shall be either a raised sidewalk, or composed of materials different from any adjacent vehicle driving or parking surfaces. Walkways accessing individual units shall be a minimum of 4 feet wide and walkways accessing multiple units shall be a minimum of 5 feet wide. Pedestrian access may be combined with vehicular travel if designed for safety and comfort as a shared pedestrian/vehicular space. Walkways providing access to two or more townhouse units shall be constructed per ADA standards to increase visitability to the site, unless infeasible due to topography. 6. Windows and openings. At least 15 percent of the façade (all vertical surfaces facing the street) shall be comprised of transparent windows and/or doors. Rough openings are used to calculate this requirement. 7. Utilities. a. Utility meters, electrical conduit, and other service utility apparatus shall be located and/or designed to minimize their visibility from the street. If such elements are mounted in a location visible from the street, common open space, or shared auto courtyards, they shall be screened with vegetation or by architectural features. b. Service, loading, and garbage areas. Developments shall provide a designated area for service elements (refuse and disposal). Such elements shall be sited along the alley, where available. Such elements shall not be located along the street frontage. Where there is no alley available, service elements shall be located to minimize the negative visual, noise, odor, and physical impacts and shall be screened from view from the street and sidewalk. The City may require a consolidated location for storage of solid waste containers, direct street access pickup, or a shared waste collection service if necessary for efficient solid waste collection.
(Previously codified as 13.06.501 and 13.06A.070, relocated to § 13.06.100 by Ord. 28613 Ex. G, 2019-09-24 ; Ord. 28725 Ex. F, 2020-12-08 ; Ord. 28793 Ex. B, 2021-12-07 ; Ord. 28821 Ex. H, 2022-06-28 ; Subst. Ord. 28902 Ex. A, 2023-08-15 ; Ord. 28903 Ex. A, 2023-08-15 ; Ord. 28905 Ex. A, 2023-08-15 ; Ord. 28966 Ex. B, 2024-05-07 ; Ord. 28986 Ex. D, 2024-11-19 ; Ord. 29042 Ex. A, 2025-06-24 ; Subst. Ord. 29108 , 2026-06-16 )
Ask a question about Tacoma law
Corpus searches the Tacoma sections it holds and shows the ones that match, with their citations. Free, no sign-in.