§ 6B.60.080 — Mandatory attendance requirements for operating engineers and boiler firemen
Municipal Code, City of Tacoma, Washington (Tacoma Municipal Code current through legislation adopted 2026-09-30 (eCode360 publication TA6977, scraped 2026-11-18)) · Tacoma Municipal Code § 6B.60.080
Corpus is an independent public-information project, not the official City of Tacoma website. Stable reference: corpuslaw.us/code/16fd12a8-be42-4389-875c-dbcc45ee2b27
§ 6B.60.080: Mandatory attendance requirements for operating engineers and boiler firemen.
All operating engineers and boiler firemen certified under this chapter shall examine each boiler and boiler logbook in accordance with the frequency of examinations required in this section. Failure to do so may result in the immediate suspension or revocation of the license of such person. The following are the minimum attendance requirements and shall not preclude in any way additional checks being made to ensure safe operation of the boiler. A. Non-automatic boilers. The following requirements relating to the frequency of observation and/or inspection of boilers shall apply to the operation of non-automatic boilers: 1. No certified operating engineer or boiler fireman in charge of a boiler or boiler plant which requires a certificate of Class I, II, III, IV, or V under this chapter for operation shall leave the immediate vicinity of the boiler or boiler plant while it is being operated. 2. No certified operating engineer or boiler fireman in charge of any boiler or steam plant may leave the premises of his or her employment when the boiler is being operated without first shutting off all sources of heat in the boiler or being relieved by a person possessing a proper class of certificate. 3. The constant attendance requirement shall not apply to the operation of power steam boilers having less than 1,000,000 Btu per hour input where such boilers are equipped with approved automatic burners, automatic burner safety controls, and automatic water-feeding devices in accordance with WAC 296-104-265, as now or hereafter amended, relating to oil and gas burners or such boilers so equipped; the attendance requirements shall be checked by a certified operator at two-hour intervals. 4. The constant attendance requirements shall not apply to the operation of small power boilers where such boilers are equipped with approved automatic burners, automatic burner safety controls, and automatic water-feeding devices in accordance with WAC 296-104-265, as now or hereafter amended, relating to oil and gas burners or such boilers so equipped; the attendance requirements shall be checked by a certified operator at least twice daily. B. Automatic boilers. The following requirements related to the frequency of observation and/or inspection of boilers shall apply to the operation of automatic boilers: 1. Low-pressure hot water boilers, low-pressure steam heating boilers, and hot water supply boilers with an input capacity of over 20,000,000 Btu per hour shall be checked by a certified operator at a minimum of two-hour intervals. 2. Low-pressure hot water heating boilers, low-pressure steam heating boilers, and hot water supply boilers with an input capacity over 5,000,000 Btu per hour, but less than or equal to 20,000,000 Btu per hour input, shall be checked by a certified operator at a minimum of six-hour intervals. 3. Low-pressure hot water heating boilers, low-pressure steam heating boilers, and hot water supply boilers with a capacity of 2,500,000 to 5,000,000 Btu per hour input shall be checked twice daily by a certified operator. 4. Small power boilers shall be checked by a certified operator at least twice daily. 5. Power hot water boilers and power steam boilers with a capacity over 100,000 Btu per hour input shall be checked by a certified operator at two-hour intervals.
( Ord. 27297 § 1, 2004-11-23 )
Ask a question about Tacoma law
Corpus searches the Tacoma sections it holds and shows the ones that match, with their citations. Free, no sign-in.