§ 6B.60.090: Duties of certified operating engineers and boiler firemen.

A. The original operating engineer or boiler fireman certificate shall be posted in a conspicuous place in the plant where the holder is employed. If the posting of his or her certificate is not practical, such certificate shall be held on his or her person and, on demand, he or she shall exhibit same. Those certificate holders that work in more than one location may copy their certificates for multiple postings. B. A certified operating engineer or boiler fireman shall perform the following duties in connection with his or her operation and maintenance of boilers: 1. Test the operation of the boiler and its control and safety devices on a routine basis in accordance with nationally recognized standards and/or boiler and control manufacturer’s written recommendations. 2. Maintain and operate the equipment in a safe manner and according to nationally recognized standards. Attendance requirements are addressed in Section 6B.60.080. 3. Prepare and maintain a boiler logbook with supplemental and pertinent boiler data attached or contained in a separate and readily accessible book, as may be required by the boiler inspector and the senior certificate holder in charge of the boiler operation. Such pertinent boiler data shall include, but not be limited to, recommended set points or operating limits for all control devices and recommended firing rates, as well as any other pertinent data for that boiler. The operating instructions shall specify that observations of unsafe conditions shall require immediate shutdown of the boiler and recording the condition in the boiler logbook. The attached supplemental information on unsafe conditions, if it remains unchanged, shall be transferable from logbooks and kept with the current book for use in comparing readings. The boiler logbook shall be kept on the premises at all times and be available for inspection. C. The certified operator shall: 1. Make entries into a boiler logbook, including pertinent boiler data required by the boiler owner, a boiler inspector, and/or the senior certificate holder in charge of the boiler operation. These entries shall list such items as any unusual conditions observed, including safety shutdowns, repairs required, adjustments required and/or made, and any procedural changes. All entries shall be made in the boiler logbook with permanent ink and must include the signature of the person making such readings, observations, or adjustments. It shall be lawful to cross out words or sentences that should be changed or corrected, but erasures are prohibited. 2. Follow designated procedures for the proper light-off, operating, and shut down as set forth in the attachment to the boiler logbook. Determine the proper firing rate and the set point or operating limits of all safety devices required by the attachment. 3. Monitor and record boiler and auxiliaries to insure safe operation. Monitoring and recording shall include, but not be limited to, water gauge level, boiler pressure, oil temperature, fuel oil suction line pressure, high and low gas pressure, stack temperature, and windbox pressure. Such temperatures, pressures, vacuums, and levels are to be observed by the boiler operator as often as safety requires, but not less frequently than required in Section 6B.60.080. 4. Attend the start-up of a boiler out of service after corrective work has been performed on the boiler, its firing equipment, or its control and safety devices, and remain in constant attendance until: a. The boiler has reached its present operating range of pressure; b. The primary controls and safety devices have been proved; and c. The boiler is acceptable for continued operation. 5. Attend the start-up of a boiler after a safety device has shut down the boiler, and remain in constant attendance until: a. The boiler has reached its present operating range of pressure; b. The primary controls and safety devices have been proved; and c. The boiler is acceptable for continued operation. 6. Be in attendance during light-off of original boiler equipment being installed and under the control of: a. The boiler manufacturer or his or her representative; b. A boiler installation contractor making the installation under a manufacturer’s written instructions and recommendations; or c. A boiler or burner installer making such installations under the manufacturer’s written instructions and recommendations. 7. Be in attendance during light-off following adjustment or authorized boiler or burner manufacturer alterations made by a representative of the manufacturer, contractor, or installer within the guarantee or warranty time period when they are obliged to render such service. The representative, contractor, or installer shall furnish, in writing, the boiler operator with recommended set points or operating limits of all control devices and recommended firing rates as well as any other pertinent data, and shall record all subsequent changes, adjustments, alterations, or recommendations in the boiler logbook with his or her signature. 8. Not allow adjustments by others without the authority of the certified operator and shall be limited to: a. Restoring control devices to original factory-operating conditions at the set point or within the operating limits determined by the certified operator and set forth in the boiler logbook. b. Repair and/or adjustment of the burner system for viscosity changes or to correct fuel-air ratios to restore proper operation at the firing rate indicated in the boiler logbook by the certified boiler operator. c. Repair and/or adjustment of any other system not directly related to the primary safety controls or to the pressure vessel to restore such system to proper operating conditions. Entries of such repairs or adjustments shall be made in the boiler logbook and shall include the name of the repair firm making such repairs or adjustments. 9. Be responsible for the proper operation, maintenance, and inspection of all controls and safety devices, according to their requirements, as follows: a. Examine each boiler and boiler logbook in accordance with the frequency of examinations required. The examination shall include the testing of all control devices required for automatic boiler by any governing codes and the testing of monitoring systems when used; and b. Inspect and test all other controls on the boiler and flush the low-water fuel cutoffs, if applicable, to assure that all control devices are in safe and proper operation. 10. Permit continued automatic boiler operation only if his or her examination, inspection, and testing indicate that the boiler is in a safe operating condition. No modification or revision to the boiler or its control devices shall be made except under his or her supervision.

( Ord. 27297 § 1, 2004-11-23 )

Ask a question about Tacoma law

Corpus searches the Tacoma sections it holds and shows the ones that match, with their citations. Free, no sign-in.