§ 15.27.604 — Wetland buffers
Municipal Code, City of Yakima, Washington (includes legislation through 10-06-2026) · Yakima Municipal Code § 15.27.604
Corpus is an independent public-information project, not the official City of Yakima website. Stable reference: corpuslaw.us/code/3c5f987e-73bf-47ab-80be-e0ec19002c73
§ 15.27.604: Wetland buffers.
A. Buffer Requirements. The following buffer widths have been established in accordance with the best available science. They are based on the category of wetland and the habitat score as determined by a qualified professional using the Washington State Wetland Rating System for Eastern Washington: 2014 Update (Ecology Publication 14-06-030, or as revised). The adjacent land use intensity is assumed to be high. 1. For wetlands that score five points or more for habitat function, the buffers in Table 27.6-1 can be used if both of the following criteria are met: a. A relatively undisturbed, vegetated corridor at least one hundred feet wide is protected between the wetland and any other priority habitats as defined by the Washington State Department of Fish and Wildlife (http://wdfw.wa.gov/hab/phshabs.htm). The corridor must be protected for the entire distance between the wetland and the priority habitat by some type of legal protection such as a conservation easement. Presence or absence of a nearby habitat must be confirmed by a qualified biologist. If no option for providing a corridor is available, Table 27.6-1 may be used with the required measures in Table 27.6-2 alone. b. The measures in Table 27.6-2 are implemented, where applicable, to minimize the impacts of the adjacent land uses. 2. For wetlands that score three to four habitat points, only the measures in Table 27.6-2 are required for the use of Table 27.6-1. 3. If an applicant chooses not to apply the mitigation measures in Table 27.6-2, or is unable to provide a protected corridor where available, then Table 27.6-3 shall be used. 4. The buffer widths in Table 27.6-1 and 27.6-3 assume that the buffer is vegetated with a native plant community appropriate for the ecoregion. If the existing buffer is unvegetated, sparsely vegetated, or vegetated with invasive species that do not perform needed functions, the buffer should either be planted to create the appropriate plant community or the buffer should be widened to ensure that adequate functions of the buffer are provided. Table 27.6-1: Wetland Buffer Requirements if Table 27.6-2 Is Implemented and Corridor Provided Wetland Category | Buffer Width (feet) based on habitat score 3—4 | 5 | 6—7 | 8—9 Category I: Based on total score | 75 | 90 | 120 | 150 Category I: Forested | 75 | 90 | 120 | 150 Category I: Bogs and wetlands of high conservation value | 190 Category I: Alkali | 150 Category II: Based on total score | 75 | 90 | 120 | 150 Category II: Vernal pool | 150 Category II: Forested | 75 | 90 | 120 | 150 Category III (all) | 60 | 90 | 120 | 150 Category IV (all) | 40 Table 27.6-2: Required Measures to Minimize Impacts to Wetlands Disturbance | Required Measures to Minimize Impacts Lights | • Direct lights away from wetland Noise | • Locate activity that generates noise away from wetland•If warranted, enhance existing buffer with native vegetation for plantings adjacent to noise source• For activities that generate relatively continuous, potentially disruptive noise, such as certain heavy industry or mining, establish an additional 10-foot heavily vegetated buffer strip immediately adjacent to the outer wetland buffer Toxic runoff | • Route all new, untreated runoff away from wetland while ensuring wetland is not dewatered• Establish covenants limiting use of pesticides within 150 feet of wetland• Apply integrated pest management Stormwater runoff | • Retrofit stormwater detention and treatment for roads and existing adjacent development• Prevent channelized flow from lawns that directly enters the buffer• Use low intensity development techniques Changes in water regime | • Infiltrate or treat, detain, and disperse into buffer new runoff from impervious surfaces and new lawns Pets and human disturbance | • Use privacy fencing or plant dense vegetation to delineate buffer edge and to discourage disturbance using vegetation appropriate for the ecoregion• Place wetland and its buffer in a separate tract or protect with a conservation easement Dust | • Use best management practices to control dust Table 27.6-3: Wetland Buffer Requirements if Table 27.6-2 Is NOT Implemented and Corridor NOT Provided Wetland Category | Buffer Width (feet) based on habitat score 3—4 | 5 | 6—7 | 8—9 Category I: Based on total score | 100 | 130 | 180 | 200 Category I: Forested | 100 | 130 | 180 | 200 Category I: Bogs and wetlands of high conservation value | 250 Category I: Alkali | 200 Category II: Based on total score | 100 | 130 | 180 | 200 Category II: Vernal pool | 200 Category II: Forested | 100 | 130 | 180 | 200 Category III (all) | 80 | 130 | 180 | 200 Category IV (all) | 50 5. Increased Wetland Buffer Area Width. Buffer widths shall be increased on a case-by-case basis as deter-mined by the administrative official when a larger buffer is necessary to protect wetland functions and values. This determination shall be supported by appropriate documentation showing that it is reasonably related to protection of the functions and values of the wetland. This documentation shall include, but not be limited to, the following criteria: a. The wetland is used by a state or federally listed plant or animal species, or has unusual nesting or resting sites such as heron rookeries or raptor nesting trees; or b. The adjacent land is susceptible to severe erosion, and erosion control measures will not effectively prevent adverse wetland impacts; or c. The adjacent land has minimal vegetative cover or slopes greater than thirty percent. 6. Buffer averaging to improve wetland protection may be permitted when all of the following conditions are met: a. The wetland has significant differences in characteristics that affect its habitat functions, such as a wetland with a forested component adjacent to a degraded emergent component or a “dual-rated” wetland with a Category I area adjacent to a lower-rated area. b. The buffer is increased adjacent to the higher-functioning area of habitat or more-sensitive portion of the wetland and decreased adjacent to the lower-functioning or less-sensitive portion as demonstrated by a critical areas report from a qualified wetland professional. c. The total area of the buffer after averaging is equal to the area required without averaging. d. The buffer at its narrowest point is never less than either three-quarters of the required width or seventy-five feet for Category I and II, fifty feet for Category III, and twenty-five feet for Category IV, whichever is greater. 7. Averaging to allow reasonable use of a parcel may be permitted when all of the following are met: a. There are no feasible alternatives to the site design that could be accomplished without buffer averaging. b. The averaged buffer will not result in degradation of the wetland’s functions and values as demonstrated by a critical areas report from a qualified wetland professional. c. The total buffer area of the buffer after averaging is equal to the area without averaging. d. The buffer at its narrowest point is never less than either three-quarters of the required width or seventy-five feet for Category I and II, fifty feet for Category III, and twenty-five feet for Category IV, whichever is greater. B. To facilitate long-range planning using a landscape approach, the administrative official may identify and preassess wetlands using the rating system and establish appropriate wetland buffer widths for such wetlands. The administrative official will prepare maps of wetlands that have been preassessed in this manner. C. Measurement of Wetland Buffers. All buffers shall be measured perpendicular from the wetland boundary as surveyed in the field. The buffer for a wetland created, restored, or enhanced as compensation for approved wetland alterations shall be the same as the buffer required for the category of the created, restored, or enhanced wetland. Buffers must be fully vegetated in order to be included in buffer area calculations. Lawns, walkways, driveways, and other mowed or paved areas will not be considered buffers or included in buffer area calculations. D. Buffers on Mitigation Sites. All wetland mitigation sites shall have buffers consistent with the buffer requirements of this chapter. Buffers shall be based on the expected or target category of the proposed wetland mitigation site. E. Buffer Maintenance. Except as otherwise specified or allowed in accordance with this chapter, wetland buffers shall be retained in an undisturbed or enhanced condition. In the case of compensatory mitigation sites, removal of invasive nonnative weeds is required for the duration of the mitigation bond, YMC § 15.27.605(I)(2)(a)(x). F. Impacts to Buffers. Requirements for the compensation for impacts to buffers are outlined in YMC § 15.27.605. G. Overlapping Critical Area Buffers. If buffers for two contiguous critical areas overlap (such as buffers for a stream and a wetland), the wider buffer applies. H. Allowed Buffer Uses. The following uses may be allowed within a wetland buffer in accordance with the review procedures of this chapter, provided they are not prohibited by any other applicable law and they are conducted in a manner so as to minimize impacts to the buffer and adjacent wetland: 1. Conservation and Restoration Activities. Conservation or restoration activities aimed at protecting the soil, water, vegetation, or wildlife. 2. Passive Recreation. Passive recreation facilities designed and in accordance with an approved critical area report, including: a. Walkways and trails; provided, that those pathways are limited to minor crossings having no adverse impact on water quality. They should be generally parallel to the perimeter of the wetland, located only in the outer twenty-five percent of the wetland buffer area, and located to avoid removal of significant trees. They should be limited to pervious surfaces no more than five feet in width for pedestrian use only. Raised boardwalks utilizing non-treated pilings may be acceptable. b. Wildlife-viewing structures. 3. Educational and scientific research activities. 4. Normal and routine maintenance and repair of any existing public or private facilities within an existing right-of-way; provided, that the maintenance or repair does not increase the footprint or use of the facility or right-of-way. 5. The harvesting of wild crops in a manner that is not injurious to natural reproduction of such crops, chemical applications, or alteration of the wetland by changing existing topography, water conditions, or water sources. 6. Drilling for utilities/utility corridors under a buffer, with entrance/exit portals located completely outside of the wetland buffer boundary; provided, that the drilling does not interrupt the groundwater connection to the wetland or percolation of surface water down through the soil column. Specific studies by a hydrologist are necessary to determine whether the groundwater connection to the wetland or percolation of surface water down through the soil column is disturbed. 7. Enhancement of a wetland buffer through the removal of nonnative invasive plant species. Removal of invasive plant species shall be restricted to hand removal. All removed plant material shall be taken away from the site and appropriately disposed of. Plants that appear on the Washington State Noxious Weed Control Board list of noxious weeds must be handled and disposed of according to a noxious weed control plan appropriate for that species. Revegetation with appropriate native species at natural densities is allowed in conjunction with removal of invasive plant species. 8. Repair and maintenance of nonconforming uses or structures, where legally established within the buffer, provided they do not increase their degree of nonconformity. I. Signs and Fencing of Wetlands and Buffers. 1. Temporary Markers. The outer perimeter of the wetland buffer and the clearing limits identified by an approved permit or authorization shall be marked in the field with temporary “clearing limits” fencing in such a way as to ensure that no unauthorized intrusion will occur. The marking is subject to inspection by the administrative official prior to the commencement of permitted activities. This temporary marking shall be maintained throughout construction and shall not be removed until permanent signs, if required, are in place. 2. Permanent Signs. As a condition of any permit or authorization issued pursuant to this chapter, the administrative official may require the applicant to install permanent signs along the boundary of a wetland or buffer. a. Permanent signs shall be made of an enamel-coated metal face and attached to a metal post or other nontreated material of equal durability. Signs must be posted at an interval of one every fifty feet, or one per lot if the lot is less than fifty feet wide, and must be maintained by the property owner in perpetuity. The signs shall be worded as follows or with alternative language approved by the administrative official: Protected Wetland Area Do Not Disturb Contact the City of Yakima Regarding Uses, Restrictions, and Opportunities for Stewardship b. The provisions of subsection (I)(2)(a) of this section may be modified as necessary to assure protection of sensitive features or wildlife. 3. Fencing. a. The applicant shall be required to install a permanent fence around the wetland or buffer when domestic grazing animals are present or may be introduced on site. b. Fencing installed as part of a proposed activity, or as required in this subsection, shall be designed so as not to interfere with species mitigation, including fish runs, and shall be constructed in a manner that minimizes impacts to the wetland and associated habitat.
( Ord. 2017-017 § 2 (Exh. B) (part), 2017 ; Ord. 2021-021 § 2 (Exh. A), 2021 )
Ask a question about Yakima law
Corpus searches the Yakima sections it holds and shows the ones that match, with their citations. Free, no sign-in.
