§ 7.65.070 — Limitations on wastewater strength
Municipal Code, City of Yakima, Washington (includes legislation through 10-06-2026) · Yakima Municipal Code § 7.65.070
Corpus is an independent public-information project, not the official City of Yakima website. Stable reference: corpuslaw.us/code/948bcde4-d125-4bfa-906e-975e8f5bea46
§ 7.65.070: Limitations on wastewater strength.
A. National categorical pretreatment standards as adopted and hereafter amended or modified by the U.S. Environmental Protection Agency (EPA) pursuant to the Act shall be met by all dischargers of the regulated industrial categories. The national categorical standards found at 40 CFR Chapter I, Subchapter N, Parts 405 through 471 are hereby incorporated. B. State requirements and limitations on discharges to the POTW shall be met by all dischargers which are subject to such standards in any instance in which they are more stringent than federal requirements and limitations, or those in this chapter or any other applicable ordinance. C. The city may from time to time amend this chapter to provide for more stringent limitations or requirements on discharges to the POTW if such amendments are deemed necessary to comply with the objectives set forth in YMC § 7.65.010, or are otherwise in the public interest. D. No discharger shall dilute its waste stream with potable or process water in any way, nor mix separate waste streams for the purpose of diluting a discharge as a partial or complete substitute for adequate treatment to achieve compliance with the standards set forth in this chapter. E. No discharger shall discharge wastewater containing concentrations (and/or mass limitations) that exceed any of the following local discharge limits unless prior written approval has been obtained from the waste-water division: Pollutant(1) Arsenic (As) | 0.48 Cadmium (Cd) | 0.049 Chloroform | 0.67 Chromium (Cr) | 5.0 Chromium (VI) | 0.43 Copper (Cu) | 0.30 Lead (Pb) | 0.19 Mercury (Hg) | 0.002 Molybdenum (Mo) | 1.14 Nickel (Ni) | 2.0 Selenium (Se) | 0.419 Silver (Ag) | 0.06 Sulfide (liquid phase) | 0.5 Zinc (Zn) | 4.2 beta-BHC | 0.01516 Endosulfan | 0.06964 Endrin | 0.00383 alpha-Chlordane | 0.00716 gamma-Chlordane | 0.00367 Chlorpyrifos | 0.01298 Lindane | 0.13324 Benzene | 0.05(3) BTEX(2) | 0.75(3) Notes: (1) | All pollutants are analyzed and reported as total mg/L. (2) | BTEX is the sum of the measured concentrations of benzene, toluene, ethylbenzene and xylene. (3) | These pollutants are based upon treatment technology (air stripping/carbon capture) and are developed for discharges from ground-water cleanup or remediation activities or other effluents containing benzene and/or BTEX and requiring the installation of treatment. The above limits apply at the point where the wastewater is discharged to the POTW. All concentrations for metallic substances are for “total” metal unless indicated otherwise. An industrial user, through enforcement action and/or permit compliance schedule, may be required to install treatment or otherwise reduce or halt a discharge of a pollutant to maintain compliance with pretreatment standards and requirements and prevent interference with the operation of the POTW, pass through and adverse effects on the quality of the receiving waters, contamination of municipal biosolids, health and safety hazards to workers in the POTW, or violations of applicable federal or state regulations. The city may impose mass limitations on discharges in cases where necessary to be consistent with federal categorical pretreatment standards. Where a discharger is subject to a categorical pretreatment standard and a local limit for a given pollutant, the more stringent limit or applicable pretreatment standard shall apply. The city may establish more stringent pollutant limits, massbased limits, additional site-specific pollutant limits, best management practices, or additional pretreatment requirements when, in the judgment of the city, such limitations are necessary to implement the provisions of this chapter. F. All known, available and reasonable methods of pretreatment, in accordance with RCW 90.48.010 and WAC 173-216-020(1), shall be used by a discharger to bring into compliance a wastewater discharge that does not comply with standards set forth in this chapter. G. The city reserves the right to enter into special agreements with industrial dischargers setting out special terms under which they may discharge wastewater to the POTW. In no case will a special agreement waive compliance with a pretreatment standard or requirement. However, the industrial discharger may request a net gross adjustment to a categorical standard in accordance with 40 CFR 403.15. They may also request a variance in accordance with 40 CFR 403.13 from the categorical pretreatment standard from EPA. Such a request will be approved only if the industrial discharger can prove that factors relating to its discharge are fundamentally different from the factors considered by EPA when establishing that pretreatment standard. An industrial discharger requesting a fundamentally different factor variance must comply with the procedural and substantive provision in 40 CFR 403.13.
( Ord. 2003-74 § 1 (part), 2003 ; Ord. 2006-07 § 27, 2006 ; Ord. 2010-54 § 2, 2010 )
Ask a question about Yakima law
Corpus searches the Yakima sections it holds and shows the ones that match, with their citations. Free, no sign-in.
