For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 10-21 — Soils

Code of General Ordinances of the City of Janesville, Wisconsin (Codified through Ordinance No. 2026-935, enacted May 26, 2026. (Supp. No. 20)) · Janesville Code of General Ordinances § 10-21

Corpus is an independent public-information project, not the official City of Janesville website. Stable reference: corpuslaw.us/code/e89b79af-a8fc-468b-af38-60bd4cb81be5

Sec. 10-21. - Soils.

(a) Loads. The permissible loads in tons per square foot on natural earth shall not exceed the bearing capacity shown in the following table. Type of Soil or Rock | Bearing Capacity Tons/Square Feet Quick sand, alluvial and filled soils, determined by tests but not more than | ½ Soft clay, sandy loam, or silt | 1 Ordinary clay | 2 Clay or fine sand, firm and dry | 3 Gravel and coarse sand, well packed | 5 Hard pan or shale | 6 Rock | Not more than 20 percent of the ultimate crushing strength of such rock (b) Borings and tests. (1) When required. In the absence of satisfactory data from immediately adjacent areas, the owner or applicant shall make borings, test pits, or other soil investigations at such locations and to sufficient depths of the bearing materials to the satisfaction of the Building Inspector. (2) Soil samples. Samples of the strata penetrated in test borings or test pits, representing the natural disposition and conditions at the site, shall be available for examination of the Building Inspector. (3) Varying soil values. When test borings indicate non-uniformity of bearing materials, a sufficient number of additional borings shall be made to establish strata levels of equal bearing capacity. (4) Costs of tests. When the safe sustaining power of the soil is in doubt, the Building Inspector shall direct that the necessary borings or tests be made by and at the expense of the applicant and under the supervision of the Building Inspector to determine the safe value. (c) Soil test procedure. (1) Soil test method. The test procedure and testing apparatus shall be approved by the Building Inspector before they are used; and a complete record of the test together with a record of the soil profile shall be filed by the licensed engineer or architect. (2) Loaded area. If results of soil tests by boring are in doubt as to safe sustaining power, the Building Inspector may require tests by loaded area method. The loaded area shall be approximately four square feet for all bearing materials; except that when the footing overlies wet clay or other soft materials, the test load shall be applied to an area of not less than ten square feet. (3) Recorded settlements. Loads shall be applied in continuous increments of not more than one-quarter of the proposed safe load. When the proposed load has been reached, it shall remain undisturbed and readings shall be recorded to determine the rate of settlement until the settlement in eight consecutive hours is less than 0.01 inches. A 50 percent excess load shall than be applied and allowed to remain in place until the rate of settlement is less than 0.01 inches in 24 hours. (4) Accuracy of loading. Tests loads applied by mechanical devices shall be automatically controlled so as to ensure not more than five percent variation in applied load. Such devices shall be calibrated prior to the test. (5) Test acceptance. The load settlement shall be represented diagrammatically, and no test shall be deemed satisfactory if the net settlement after removal of the test load exceeds 0.01 inches per ton of gross load applied.

(Code 1976, § 15.01.220)

Ask a question about Janesville law

Corpus searches the Janesville sections it holds and shows the ones that match, with their citations. Free, no sign-in.