For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 19.052 — Coastal Floodplain District (CFD)

Code of General Ordinances of the City of Kenosha, Wisconsin (Codified through Ordinance No. 33-26, adopted September 9, 2026. (Supp. No. 11, Update 2)) · Kenosha Zoning Ordinance § 19.052

Corpus is an independent public-information project, not the official City of Kenosha website. Stable reference: corpuslaw.us/code/be4873f9-0948-48ed-9da2-f81a55ac3316

19.052. - Coastal Floodplain District (CFD).

(1) Applicability. The provisions of this section apply to all Coastal Floodplain Districts (CFD) shown on the floodplain zoning maps, which includes zones V, V1-30, and VE. Where a floodway shown on the floodplain zoning maps, or a floodway determined as explained in Section 19.015(3)(d) or a regulatory floodway identified pursuant to Section 19.051(5), extends into a Coastal Floodplain District, development shall comply with the standards of Section 19.03 and Section 19.053. (2) Standards for Development in the Coastal Floodplain District. Development in the CFD district shall meet the requirements of Section 19.02, as well as the following: a. New construction shall be located landward of the Ordinary High-Water Mark. b. Bulkheads, seawalls, revetments, and other erosion control measures shall not be connected to the foundation or superstructure of a building and shall be designed and constructed so as not to direct floodwaters or increase flood forces or erosion impacts on the foundation or superstructure of any building. c. Man-made alterations of sand dunes are prohibited unless an engineering report documents that the alterations will not increase potential flood damage by reducing the wave and flow dissipation characteristics of the sand dunes. d. The use of fill for structural support of buildings is prohibited. 1. Non-structural fill shall be permitted only if an engineering report demonstrates that the fill will not cause runup, ramping, or deflection of floodwaters that cause damage to buildings. e. New construction and substantial improvement of buildings shall be elevated, consistent with SPS 321.34, on pilings or columns so that the bottom of the lowest horizontal structural member of the lowest floor (excluding the pilings or columns) is elevated to or above the FPE. 1. The pile or column foundation and structure attached thereto shall be anchored to resist flotation, collapse, and lateral movement due to the effects of wind and water loads acting simultaneously on all building components. Water loading values shall be those associated with the base flood. Wind loading values shall be those defined according to American Society of Civil Engineers 7-16, Minimum design loads and associated criteria for buildings and other structures, or other equivalent standard. 2. A registered professional engineer or architect shall develop or review the structural design, specifications, and plans for the construction, and shall certify that the design and methods of construction to be used are in accordance with accepted standards of practice for meeting the provisions of Section 19.053(2)(e). f. New construction and substantial improvement of buildings shall have the space below the lowest floor either free of obstruction or constructed with non-supporting breakaway walls, open wood latticework, or insect screening intended to collapse without causing collapse, displacement, or other structural damage to the elevated portion of the building or supporting foundation system. 1. For the purpose of Section 19.053(2)(f), a breakaway wall shall have a design safe loading resistance of not less than ten (10) and not more than twenty (20) pounds per square foot. 2. Use of breakaway walls which exceed a design safe loading resistance of twenty (20) pounds per square foot (either by design or where so required by local or state codes) may be permitted only if a registered professional engineer or architect certifies that the designs proposed meet all of the following conditions: a) Breakaway wall collapse shall result from a water load less than that which would occur during the base flood; and b) The elevated portion of the building and supporting foundation system shall not be subject to collapse, displacement, or other structural damage due to the effects of wind and water loads acting simultaneously on all building components (structural and non-structural). Water loading values shall be those associated with the base flood. Wind loading values shall be those defined according to American Society of Civil Engineers 7-16, Minimum design loads and associated criteria for buildings and other structures, or equivalent standard. 3. All space enclosed by breakaway walls, open wood latticework, or insect screening below the lowest floor shall be used solely for parking, building access, or storage. g. Require within flood-prone areas: 1. New and replacement water supply systems to be designed to minimize or eliminate infiltration of flood waters into the systems; and 2. New and replacement sanitary sewage systems to be designed to minimize or eliminate infiltration of flood waters into the systems and discharges from the systems into flood waters and onsite waste disposal systems to be located to avoid impairment to them or contamination from them during flooding. h. All mobile recreation vehicles must be on site for less than one hundred eighty (180) consecutive days and be either: 1. fully licensed and ready for highway use; or 2. shall meet the standards of Sections 19.053(2)(a) through 19.053(2)(g) inclusive. A mobile recreational vehicle is ready for highway use if it is on its wheels or jacking system, is attached to the site only by quick- disconnect type utilities and security devices and has no permanently attached additions. i. Manufactured homes placed or substantially improved within the Coastal Floodplain District shall meet the standards of Sections 19.053(2)(a) through 19.053(2)(g) inclusive.

(Ord. No. 08-24, § 11, 2-21-2024)

Ask a question about Kenosha law

Corpus searches the Kenosha sections it holds and shows the ones that match, with their citations. Free, no sign-in.