§ 19.062 — Floodway District
Code of General Ordinances of the City of Kenosha, Wisconsin (Codified through Ordinance No. 33-26, adopted September 9, 2026. (Supp. No. 11, Update 2)) · Kenosha Zoning Ordinance § 19.062
Corpus is an independent public-information project, not the official City of Kenosha website. Stable reference: corpuslaw.us/code/4ee7a705-0174-4259-b1dd-5f8b1c8e6ec0
19.062. - Floodway District.
1) No modification or addition shall be allowed to any nonconforming structure or any structure with a nonconforming use in the Floodway District, unless such modification or addition: a) Has been granted a permit or variance which meets all ordinance requirements; b) Meets the requirements of Section 19.061; c) Shall not increase the obstruction to flood flows or regional flood height; d) Any addition to the existing structure shall be floodproofed, pursuant to Section 19.075, by means other than the use of fill, to the flood protection elevation; and, e) If any part of the foundation below the flood protection elevation is enclosed, the following standards shall apply: 1. The enclosed area shall be designed by a registered architect or engineer to allow for the efficient entry and exit of flood waters without human intervention. A minimum of two (2) openings must be provided with a minimum net area of at least one (1) square inch for every one (1) square foot of the enclosed area. The lowest part of the opening can be no more than twelve (12) inches above the adjacent grade; 2. The parts of the foundation located below the flood protection elevation must be constructed of flood-resistant materials; 3. Mechanical and utility equipment must be elevated or floodproofed to or above the flood protection elevation; and 4. The use must be limited to parking, building access or limited storage. 2) No new on-site sewage disposal system, or addition to an existing on-site sewage disposal system, except where an addition has been ordered by a government agency to correct a hazard to public health, shall be allowed in the Floodway District. Any replacement, repair or maintenance of an existing on-site sewage disposal system in a floodway area shall meet the applicable requirements of all municipal ordinances, Section 19.075(3) and Chapter SPS 383, Wis. Adm. Code. 3) No new well or modification to an existing well used to obtain potable water shall be allowed in the Floodway District. Any replacement, repair, or maintenance of an existing well in the Floodway District shall meet the applicable requirements of all municipal ordinances, Section 19.073(3) and Chapters NR 811 and NR 812, Wis. Adm. Code.
(Ord. No. 08-24, § 11, 2-21-2024)
Ask a question about Kenosha law
Corpus searches the Kenosha sections it holds and shows the ones that match, with their citations. Free, no sign-in.