§ 32.06 — Rules and Regulations Governing the Water System
Code of General Ordinances of the City of Kenosha, Wisconsin (Codified through Ordinance No. 33-26, adopted September 9, 2026. (Supp. No. 11, Update 2)) · Kenosha Code of General Ordinances § 32.06
Corpus is an independent public-information project, not the official City of Kenosha website. Stable reference: corpuslaw.us/code/82e5cfbc-3207-48a3-99f0-6f1574e253f6
32.06. - Rules and Regulations Governing the Water System.
Rule 06-01. Required Water Service and Connection. B. Unsafe Well Water. Where inhabited property that fronts a Water Utility water main is serviced by a private well, and where water from that well is bacteriologically unsafe or toxic, then the owner of said property shall be required to connect said property into an abutting water main and use Water Utility water for domestic purposes, subject to Water Utility Rules and Regulations, within thirty (30) calendar days following notification to the property owner that such a connection is required. B. Safe Well Water. Where inhabited property that fronts a Water Utility water main is serviced by a private well that is subject to a Well Permit under Section 32.09, and the water from that well is bacteriologically safe, then the owner of said property shall be required to connect their property into an abutting water main within one (1) year. The connection shall be extended into the property and a water meter shall be set. (See Section 32.09) Water from the Water Utility need not be used as long as a Well Permit is maintained and the water from the well in bacteriologically safe. Rule 06-02. Water Connection Charges. Owners shall be responsible, where the water main extension has been approved by the Water Utility through a developer's agreement, for the water service lateral installation costs from the main through the curb stop. The initial water service lateral(s), not installed as part of a developer's agreement or an assessable Utility extension, will be installed from the main through the curb stop by the Water Utility, for which there will be charges as approved by the Wisconsin Public Service Commission. Rule 06-03. Water Service Pipe. Water service pipe extending from the building to the Water Utility curb stop within the public right-of-way or easement, shall be installed in accordance with Wisconsin Administrative Code, SPS 382. All curb stops for controlling the supply of water to customers shall be placed between the curb line of the street and sidewalk, where sidewalk is present or proposed, with the top of the box even with the grade of sidewalk or parkway. Representative detail drawings are on file at the Water Utility Engineering Office and are available for review upon request. Each water service lateral shall have a curb stop valve. When the water main is within ten (10) feet of the property line or within an easement, the tapping valve (corporation stop) of a service four (4) inch or greater in diameter may be considered to be the curb stop. If installed in this manner, the property owner is responsible for maintaining the entire water lateral, beginning at the tapping valve. The Utility is responsible for the tapping valve. The minimum size of service pipe from the curb stop to the water meter shall be one (1) inch in diameter. The minimum size service from water main to curb stop for a residential unit, where the distance from the water main to the meter is greater than one hundred (100) feet, shall be one and one-half-inch diameter. In all cases the domestic service shall be sized to provide a minimum of twelve (12) gpm at twenty (20) psi at the water meter for each dwelling unit. The water service from the curb stop to the building shall conform to the standards listed in Wisconsin Administrative Code, SPS 384. The water service from the main to the curb stop shall be type K copper for one-inch, one and one-half-inch and two-inch services; poly-encased ductile iron pipe Class 53 or C900 PVC pipe for four-inch, six-inch and eight-inch services; and poly-encased ductile iron pipe Class 52 or C900 PVC pipe for services larger than eight (8) inches. Alternate material may only be used upon written approval from the General Manager. Water service pipe shall be laid at least five and one-half (5½) feet below the planned finished grade of the street, lawn or below the existing grade, whichever is lower. The water service pipe may be laid in a sewer connection trench if it is properly shelved to one (1) side of the trench or at least one (1) foot above the sewer lateral. No new or replacement service curb stop shall be laid deeper than six and one-half (6½) feet below the established grade. No person, party or contractor shall cover or permit the covering of any water connection line until the installation has been inspected and approved by the Utility. The contractor shall subject the water piping to a test in the presence of a City Plumbing Inspector, as required by the State Plumbing Code. When a service pipe larger than two (2) inches is used to supply an individual service or a private water main extension, the service pipe shall be tested in accordance with Rule 06-36 prior to any pressure test or water usage. A water service may cross one (1) or more parcels to service another parcel provided only one (1) parcel is served and the water service meets all of the following requirements/conditions: 1. Approved by the General Manager of the Water Utility; 2. A copy of a recorded easement between parcel owners is delivered to the Water Utility; 3. A "Deed Covenant—Rights to Maintain Sewer and/or Water" (approved by the City Attorney) is recorded and a copy of the recorded document is delivered to the Water Utility. Rule 06-04. Responsibility for Water Service Pipes, Appurtenances and Connections. The Water Utility is responsible for any necessary repairs to or replacement of the water service pipe and curb stop, from the curb stop to the Water Utility's water distribution main located in an easement or in the public right-of-way. When the water main is within ten (10) feet of the property line or within an easement, the tapping valve (corporation stop) of a service four (4) inch or greater in diameter may be considered to be the curb stop. If installed in this manner, the property owner is responsible for maintaining the entire water lateral, beginning at the tapping valve. The Utility is responsible for the tapping valve. The property owner is responsible for the installation, maintenance, and any necessary repairs to, or replacement of the water service pipe and all appurtenances and connections from within the building to the curb stop, except for the water meter and meter horn. The Water Utility is responsible for the installation, maintenance, and any repairs to, or replacement of the water meter and meter horn. In the event any repair or replacement of the owner's water service pipe is required, the owner, at his/her expense, must make the repair or replacement within twenty (20) days after receiving written notice from the Water Utility that repair or replacement is required. If the necessary repair or replacement is not completed by the owner within said twenty (20) days, or if the condition requiring repair or replacement is of such a nature as to cause a danger to persons or property, the Water Utility may disconnect the water connection or make the necessary repair or replacement and charge the cost to the property owner, and specially assess the property served. Any costs or expenses incurred by the Water Utility which are the responsibility of the owner as stated in this Chapter, shall be charged to the property owner and may be specially assessed to the property served. The Water Utility, as a public service, and upon the request of the property owner, may enter private property which receives its water supply from the Water Utility to attempt to locate a water pipe break. Under normal circumstances, the Water Utility will not perform or arrange to perform any repair work on private property. The Water Utility may, at its discretion, shut off water services to the premises without the consent of the owner or occupant, where there is evidence that the water pipe break may endanger persons, damage property, or create a public nuisance. Rule 06-05. Water Service Leaks. If the Water Utility makes repairs to a water service pipe on the Water Utility's side and cannot reconnect to the service pipe on the homeowner's side because of a deteriorated service pipe or if the water service begins leaking during the Water Utility's maintenance to the meter or other Water Utility facilities, and it is determined that the owner's water service pipe must be replaced, then the Water Utility and the property owner shall equally share the cost of replacing the water service pipe on the owner's side. Cost sharing shall only occur if the Water Utility attempted to reconnect or repair the water service pipe on the owner's side and determined that the service pipe on the owner's side requires replacement. The property owner may arrange to have a contractor, acceptable to the Water Utility, replace or repair the water service pipe and then request 50 percent reimbursement of expenses from the Water Utility. Cost estimates must be approved by the General Manager prior to contracting the work. The property owner shall be responsible for all costs for restoration on his/her property. The Water Utility shall be responsible for all costs for restoration of the right-of-way, including sidewalk, parkway, curb and gutter and road repairs. Rule 06-06. Lead Service Replacement. A. Intent and Purpose. Lead service lines have the potential to leach lead into drinking water. Disturbing or reconnecting to an existing lead service line may increase lead levels in drinking water. Elevated lead levels in drinking water have been determined to cause health problems in young children, pregnant women and their unborn children, and are also potentially harmful to adults. The Common Council therefore finds it in the public interest to establish a comprehensive program for removing and replacing all lead service lines within and connected to the Water Utility water distribution system. B. Authority. This Chapter is enacted pursuant to Wis. Stats. §§ 62.11(5) and 196.372. C. Definitions. This Chapter shall be interpreted so that the intent and purpose described may be accomplished. Words and phrases shall be understood according to common meanings unless the contrary is clearly indicated. In addition to the definitions for this Chapter found in Section 32.01, definitions of terms used in this Section are listed below: Customer-side service line. The Property Owner's water service line, from the outlet of the curb stop to the inlet of the customer's water meter. Distribution System. The network of water pipes, including mains and service lines, owned and operated by the Water Utility. Lead Service Line or LSL. A Service Line made from or including lead, or galvanized material which is or was downstream of lead. The term includes the customer-side service line and/or the Utility-side service line. Property. Real property as defined in Wis. Stats. § 70.03. Property Owner. A person or legal entity having a possessory interest, legal or equitable, in property, which defined term includes an estate, trust or lien. Plumbing Contractor. A person, firm, corporation or other entity licensed by the State of Wisconsin to perform plumbing work in the City. Utility-side service line. The Utility-owned portion of the water service line from the water main to the outlet of the curb stop, including the curb stop, but not the outlet joint of the curb stop. D. Lead Service Line Replacement Requirement. 1. As provided in this Chapter, all existing lead service lines connected to the distribution system shall be replaced with water service lines constructed of materials approved by the City. 2. Where both the customer-side and Utility-side service lines are constructed of lead, the replacement of both sides of the service line shall be completed under a schedule established by the Utility. 3. Where only the customer-side service line is constructed of lead, the replacement of the customer-side LSL shall be completed under a schedule established by the Utility. 4. The Utility reserves the right to make lead service replacement mandatory under the following circumstances: a. If the Utility receives State or Federal funding allowing for the payment of 100% of the customer-side LSL and the Property falls within a designated boundary (i.e. - Census Tract) in the City for which such funding is available. b. If the City of Kenosha is reconstructing a roadway and lead service lines are known to exist within the boundary of the project. Reconstructing in this case is defined as the removal of the existing pavement and base course down to subgrade, installation of new base course, and the placement of concrete pavement. c. For Properties with leaking or failed customer-side or Utility-side service lines. d. For Properties where the Water Utility is replacing the Utility-side service line, on either a planned or emergency basis. 5. If a Property is subject to service line replacement in accordance with the conditions listed in D.4.b. through D.4.c. above and is outside of a designated boundary for State or Federal funding of the customer-side LSL replacement as described in subparagraph D.4.a, such Property may be eligible for grant funding from the Utility as described in subparagraph G. 6. As of the effective date of the ordinance from which this Chapter is derived, no person, other than a Utility employee or agent, may connect a customer-side LSL to a non-lead Utility-side service line, except as a temporary emergency repair. E. Identification of Lead Service Lines. 1. Upon notice from the Utility, any person or entity who owns, manages or otherwise exercises control over a property connected to the distribution system shall allow the Utility to inspect the customer-side service line to determine the material of construction. (See Rule 05-04.) 2. The Utility shall create and maintain a record of the location of all identified lead service lines in the City. F. Private Replacements Done in Conjunction with Utility Replacements. 1. Prior to scheduling the replacement of Utility-side service lines, the General Manager, or his/her designee, shall inspect all affected customer-side service lines for the presence of lead. In the event that the Property Owner fails to provide access to the interior of any improvement to accomplish such inspection, the General Manager shall take such steps necessary to make the determination, and shall collect the cost therefore from the Property Owner, including by imposition of a special charge. 2. If the customer-side service line is found to be constructed of lead, the Property Owner will be notified in writing of that fact, along with notification that the Property Owner must replace the customer-side service line. 3. Replacement of the customer-side LSL must be completed by the Property Owner at the time the Utility-side service line is replaced unless an extension is allowed under subparagraph F.7. 4. A Property Owner having a customer-side LSL will be notified in writing at least forty-five (45) days prior to the date for scheduled replacement of the Utility-side service line. 5. Within thirty (30) days of receipt of the replacement notice, Property Owner must schedule replacement of the customer-side service lateral to coincide with the scheduled replacement of the Utility-side service line. 6. Failure to commence work on the replacement of the customer-side LSL when scheduled pursuant to this Chapter or to complete such work within a reasonable time after commencement of the work, may result in a citation for the violation to the Property Owner. 7. Upon written request of the Property Owner with demonstration by the Property Owner of a compelling need, the General Manager may, at his or her discretion, extend the time requirement for replacement of the customer-side LSL, unless the General Manager determines that doing so will create an imminent threat to the health, safety or welfare of the public. G. Financial Assistance for Customer-Side LSL Replacements Outside of Designated State or Federally Funded Areas. 1. If a property falls outside of an area for which State or Federal funding is available, the Utility may provide an eligible Property Owner with financial assistance to replace a customer-side LSL if the Utility maintains a financial assistance program that has received the approval of the Public Service Commission of Wisconsin and that has available funding. 2. If the Utility maintains an approved financial assistance program, the Utility may provide eligible Property Owners with a grant for up to fifty percent (50) of the cost of customer-side LSL replacement, but not to exceed a maximum grant amount established by the Board of Water Commissioners. The Board of Water Commissioners shall periodically review and adjust the maximum grant amount. 3. Financial assistance granted to eligible Property Owners shall be in accordance with the following priority: a. For Properties with leaking or failed customer-side or Utility-side service lines. b. For Properties where the Water Utility is replacing the Utility-side service line, on either a planned or emergency basis. c. For Properties with licensed child care facilities and schools. d. For Properties where children under the age of seven (7) or pregnant women reside. e. To all remaining Properties with customer-side LSLs. 4. A Property Owner is eligible for financial assistance for the purpose of replacing the customer-side LSL if the Property Owner satisfies all of the following criteria: a. The Property Owner alone, or collectively with others, owns the entire fee simple title to the Property served by a customer-side LSL. b. The Property Owner's customer-side LSL is either attached to a Utility-side service line that is not a LSL, or a Utility-side LSL scheduled for replacement and for which the Property Owner has been notified by the Utility of such scheduled replacement. c. The Property Owner of subparagraph a, above, agrees to have the work done by a Utility-approved Plumbing Contractor and in compliance with this Chapter. d. The Property Owner of subparagraph a, above, executes a temporary right of entry and construction easement authorizing the Utility access to the dwelling as needed. 5. Written applications for financial assistance shall include the following: a. A completed application on a form furnished by the Utility signed by the Property Owner of subparagraph 4.a., above. The completed application form shall include a certification by the Property Owner that attests that all eligibility criteria are met. b. The executed documentation required by paragraph G.4. c. Copies of written quotes from at least two (2) pre-qualified Plumbing Contractors for the replacement of the customer-side LSL. A pre-qualified Plumbing Contractor is one (1) that either is on the Utility's Prequalified Plumbing Contractor list, or is a Plumbing Contractor that is properly licensed to work in the State of Wisconsin, has filled out a Prequalification Form at the Kenosha Water Utility office, and has been accepted by the Utility. 6. Prior to commencement of any work, the Utility shall determine if the Property Owner is eligible for financial assistance, and if there is money available to provide financial assistance to replace the customer-side LSL. Such determination shall be provided in writing to the Property Owner who applied. 7. Customer-side service line replacement work must be accomplished in a worker-like manner and be coordinated with any Utility replacement work as required by paragraph F. 8. Upon completion of the customer-side service line replacement, the Property Owner shall provide the Utility with a copy of the invoice from the Plumbing Contractor. Upon proof of completion satisfactory to the Utility, the Utility shall pay directly to the Plumbing Contract the amount of financial assistance approved by the Utility for replacement of the customer-side LSL. The Utility shall notify the Property Owner of the payment. 9. In addition to the provision of grants, the Utility may provide financial assistance for customer-side LSL replacements in the form of loans. In accordance with Wis. Stats. § 66.0627, the Utility shall require that an eligible Property Owner enter into a loan agreement, which provides that loan repayments be paid in annual installments, with installment payments being placed on the tax roll as a special charge. The total amount of grants and loans provided as financial assistance by the Utility may not exceed the actual cost of replacement of the customer-side LSL. 10. Disputes regarding eligibility for financing may be appealed to the Board of Water Commissioners. H. Severability. If any subsection or portion of this Section is for any reason determined to be invalid or unconstitutional by the decision of a court of competent jurisdiction, that subsection or portion shall be deemed severable and shall not affect the validity of the remaining subsections or portions of this Section. I. Authority to Discontinue Service. As an alternative to any other methods provided for obtaining compliance with this section regarding replacement of a customer-side LSL, the Utility may, after at least thirty (30) days of giving notice, discontinue water service to such property served by customer-side service LSL after reasonable opportunity has been given to make the appropriate replacement. Rule 06-07. Frozen Laterals. A. Thawing of a customer's lateral shall be at the Water Utility's expense if: 1. The frozen lateral is a direct result of a Water Utility disconnect and the disconnection occurs during a time when conditions are such that frozen lateral could reasonably be expected to occur or; 2. The customer's portion of lateral is electrically conductive and: a. It is the first thaw for the customer at the location during the current winter season; and b. The Water Utility has not provided the customer with seasonal notice of the corrective actions to be taken for a known condition. B. Lateral thawing shall be at the customer's expense if: 1. The customer's lateral is not electrically conductive and the frozen lateral is not a direct result of a Water Utility disconnect as set forth in Subsection A.1.; or 2. The customer neglected to provide or maintain proper insulation or protection for the lateral according to standard accepted practice, or specific Water Utility instructions on, for example, the required depth of burial needed to prevent freezing; or 3. The Water Utility advises the customer of the corrective measures to be taken and the customer does not follow the Water Utility's advice. (See Section PSC 185.35 (7) for bill adjustment where a Water Utility requests a customer to let water flow to prevent freezing); or 4. If the Water Utility disconnects for a dangerous condition. Rule 06-08. Number of Meters on One (1) Water Service Pipe. Each parcel of property shall have only one (1) water service with only one (1) water meter (customer) unless otherwise authorized and approved in writing by the General Manager of the Water Utility, except customers may have a second water meter for "lawn sprinkling" (no sanitary sewer charge) in the same location as the domestic meter. A parcel with more than one (1) building to be served may split a single service from the Water Utility to serve each building, if installed per the State Plumbing Code. Each building must have a meter, and each meter must have a separate exterior curb stop that is accessible to Water Utility personnel. Owners of multi-unit dwelling units or condominiums must apply, in writing, and must obtain approval from the General Manager for the installation of separate water meters for each housing unit served by a single service pipe. Rule 06-09. Customer Responsibilities. The Water Utility, absent negligence on its part, shall not assume responsibility for any damages incurred by a customer or property owner arising out of a broken or defective water main or service pipe where the installation thereof was performed in a good and workmanlike manner or from damages arising from insecure boilers, variation in water pressure, or the water hammer from the mains or from the failure of any water fixture. The Water Utility shall not be responsible for the cost of any water loss or property damage arising out of a broken or defective service pipe or appurtenance thereto where the property owner is responsible for the maintenance thereof. Each customer shall be responsible for maintaining their premises which receive service in as safe a condition as the nature of the premises shall reasonably permit so as to protect employees of the Water Utility from harm when they enter said premises in the performance of their duties. Each customer is also responsible for providing the Water Utility with access to their premises as provided in Rule 05-04. Water service may be temporarily discontinued (shut off) should a customer fail to comply with this Section. Rule 06-10. Meters Required. All water services within the Retail Service Area shall be metered. All meters shall be furnished by the Water Utility and shall be installed by or under the supervision of the Water Utility. Only one (1) meter will be installed for each service pipe, unless otherwise approved by the General Manager. The meter must be installed before the City of Kenosha, Department of City Inspections will issue a certificate of occupancy. No connection to the service pipe shall be made before the meter. Submeters shall not be installed, read or maintained by the Water Utility. Rule 06-11. Water Meters, Remote Registers and Meter Bypasses—How Placed. A. Meters shall be placed in the basement where a basement exists. The meter must be placed on the service pipe within twelve (12) inches of the inside wall and between twelve (12) inches and twenty-four (24) inches above the floor. If no basement exists or the service pipe is extended beyond where the service enters the building foot print, the service pipe shall be buried under the concrete floor (no exposed pipe) until it rises to the meter. The service pipe riser to the meter shall be perpendicular to the floor and secured or reinforced to support the meter. The meter shall be so placed as to be easily accessible and shall be kept free from all obstructions so that it may be easily read, maintained and inspected and it shall be protected by the property owner from freezing and other damage. All meters shall have a valve on both the inlet and outlet side of meter. All meters of size from five-eighths (⅝) inch through one (1) inch shall be set with the use of a meter horn supplied by the Water Utility. Meter horns shall be furnished upon application for a meter and shall be installed by a licensed plumber. Representative detail drawings are on file at the Water Utility Engineering Office and are available for review upon request. Meters installed in newly constructed single family units shall be a minimum of three-quarter (¾) inch. All meters one and one-half inch (1½) or larger shall be provided with a bypass connection. The bypass connection shall be teed off the main service pipe before the inlet valve and after the outlet valve which are required at the meter. Representative detail drawings are on file at the Water Utility Engineering Office and are available for review upon request. The size of the bypass connection shall not be less than one (1) normal pipe size less than the meter size. A locking valve, approved by the Utility, shall be installed on the bypass and will be locked by the Water Utility. A meter test plug shall be provided between the outlet side of the meter and outlet valve for three (3) inch and larger meters. Existing meter bypass connections installed without locking bypass valves shall be allowed to remain in service unless it is discovered that the valve has been tampered with or operated without the consent of the Water Utility, whereby the Water Utility will require the owner to replace the existing valve with a locking bypass valve in the meter bypass connection which shall be locked by the Water Utility. A remote water meter register is required for all water meters, and shall be attached directly to the outside of the building or structure wall. The remote register shall be approximately four (4) feet above finished ground elevation and located by the Water Utility where it will be free of obstruction and easily accessible. Wiring from meter to remote register will be exposed on both the interior and exterior of a residential (single family or duplex) building unless the owner, at his/her expense, provides a one-half-inch conduit. Any owner or builder of a new duplex, who receives authorization for two (2) separate meters, shall provide a one-half-inch conduit with three (3) #18 wires from each meter to the remote reader. The remote reader shall be field located and approved by the Water Utility. Wiring from meter to remote register shall be three (3) #18 wires in a one-half-inch conduit for each meter for commercial and industrial buildings. The remote register or reader shall be field located and the location shall be approved by the Water Utility. Remote water meter registers shall be installed only by authorized employees of the Water Utility. The Water Utility does not assume responsibility for the defacement or damage of property caused by necessary holes, fastenings or other work required for proper installation. The remote water meter registers, wiring and other appurtenances required for the installation shall be and remain the property of the Water Utility. The Water Utility shall have the right of access to install, read, remove, test and inspect the meter and installation as a condition of providing water service. Rule 06-12. Location of Meters, Remote Registers—Not Obstructed. In the event that a meter or remote register is situated in a location that is inaccessible or difficult to access, the Water Utility shall notify the owner of such condition, and if such condition is not remedied in a manner satisfactory to the General Manager within thirty (30) days after receipt of such notice, the water service may be discontinued (shut off) by the Water Utility and remain discontinued (shut off) until such condition is remedied. Rule 06-13. Meters and Meter Bypasses Not to be Interfered With. Meters and meter bypasses shall be left in the condition and manner as set by the Water Utility and shall not be tampered with by anyone in any manner whatsoever. No meter shall be moved or disturbed without written permission from the General Manager, and then only by a licensed plumber. In no case shall a service pipe coupling bypass be inserted in the service pipe in place of a meter, except that in case of frozen service pipes or frozen meters. Only a licensed plumber, upon notification to the Water Utility, or the Water Utility will be permitted to make such insertion. Any person violating this provision will be required, as a condition of future water service, to pay an amount equal to the amount of damage sustained by the Water Utility by reason of loss of, or damage to the meter, and the loss of revenue from the sale of water by reason of inaccurate water usage registration on meter. Diversion of service around the meter, which has not been previously authorized by the Water Utility, may result in a disconnection and refusal of service in accordance with Wisconsin Administrative Code, PSC § 185.37. Rule 06-14. Meter Repairs. All meters, damaged by frost, hot water or causes other than ordinary wear and tear, will be repaired or replaced by the Water Utility and the cost thereof shall be charged to the owner of the property served. All repairs or replacements due to ordinary wear and tear of the meter will be made by the Water Utility at the expense of the Water Utility. Prior to replacing a meter, the condition and configuration of the service pipe and the valves on both the inlet and outlet sides of the meter will be assessed to determine the potential for future water leaks. In those instances where the piping and/or valves are in poor condition and/or the configuration of the plumbing is such that future water leaks are likely, the owner may be asked to sign a "hold harmless" agreement prior to the replacement of the meter. Plumbing configurations that are in violation of Wisconsin Administrative Code, SPS 381 through 387 (Plumbing) will be referred to City of Kenosha, Department of City Inspections. Rule 06-15. Meter Pits. If a meter pit must be placed outside of the premises, the owner must request special written permission therefor and construct the pit according to specifications of the Water Utility to obtain water service. Representative detail drawings are on file in the Water Utility Engineering Office and are available for review upon request. New residential units shall be designed in such a manner that outside meter pits are not required. In all cases of existing or new meter pits, the owner is responsible to maintain the pit according to specifications of the Water Utility. In the event that a pit does not meet Water Utility specifications, the Water Utility shall notify the owner of such condition, and if such condition is not remedied in a manner satisfactory to the General Manager within thirty (30) days after receipt of such notice, the water service may be discontinued (shut off) by the Water Utility and remain discontinued (shut off) until such condition is remedied. The meter must be accessible for meter reading and testing at all times and is subject to all other rules governing meters. Rule 06-16. Failure to Read Meters. Where the Water Utility is unable to read a meter, the fact will be plainly indicated on the bill, and either an estimated bill will be computed or the minimum charge applied. The difference shall be adjusted when the meter is again read, that is, the bill for the succeeding billing period will be computed with the gallons or cubic feet in each block of the rate schedule doubled, and credit will be given on that bill for the amount of the bill paid the preceding period. Only in unusual cases shall more than three (3) consecutive estimated or minimum bills be issued. Rule 06-17. Testing Meters. Water meters shall be tested in accordance with Wisconsin Administrative Code PSC § 185.75. Rule 06-18. Meters Failing to Register. Water meters failing to register shall be billed in accordance with Wisconsin Administrative Code, PSC § 185.34. Rule 06-19. Collection of Overdue Bills. An amount owed by the customer may be levied as a tax as provided in Wis. Stats. § 66.0809. Rule 06-20. Adjustment of Water Bill. An adjustment of a water bill may only be made in accordance with Wisconsin Administrative Code, PSC § 186.35. Rule 06-21. Disconnection and Refusal of Service. Disconnection and refusal of service shall be in accordance with Wisconsin Administrative Code, PSC § 185.37. Rule 06-22. Deferred Payment Agreement. Deferred payment agreements shall be in accordance with Wisconsin Administrative Code, PSC § 185.38. Rule 06-23. Dispute Procedures. Dispute procedures shall be in accordance with Wisconsin Administrative Code PSC § 185.39. Rule 06-24. Breaking Seals and Locks Prohibited. No person shall break any seal or lock upon any meter, meter bypass, remote register, valve, private fire hydrant or other fixtures that may be sealed by the Water Utility. Rule 06-25. Check Valve or Other Protective Devices. When water service is provided to a hot water boiler or other pressure vessel, a check and relief valve or other protective device shall be installed, as required by Wisconsin Administrative Code, SPS 381 through 387 (Plumbing). The Water Utility may require vacuum breakers, backflow preventers or check valves on any water service if it is found necessary to protect the public water supply, as may be determined by the General Manager. Rule 06-26. Private Fire Service Pipe. Private fire service pipes may be unmetered or metered as authorized by the General Manager. Fire service pipe meters must be set in accordance with Rule 06-12 where their use is required by the Water Utility. Representative detail drawings are on file at the Water Utility Engineering Officer and are available for review upon request. The rates for Private Fire Protection service shall be based on the service pipe size as authorized by the Public Service Commission. Rule 06-27. Seasonal or Intermittent Use. Charges for seasonal or intermittent use are authorized by the Wisconsin Public Service Commission. Rule 06-28. Permits for Temporary Water Service. Permits for temporary water service shall be issued and obtained from the City of Kenosha Department of City Inspections. Applicants for a new Building Permit shall also make application for Temporary Water Service Permit. Charges for Temporary Water Service Permits shall be as authorized by the Wisconsin Public Service Commission. No Occupancy Permit for a building serviced by a water service exceeding two (2) inches in diameter shall be approved until such time as the Water Utility has provided the Plumbing Inspector with written verification that the water service that serves the building has been successfully tested in accordance with Rule 06-36. Rule 06-29. Discontinuance of Service. Any property owner desiring to discontinue the use of water service must give written notice to the Water Utility of such discontinuance, providing within such notice the location of the relevant premises served and the date water service is to be discontinued. Water service discontinuance policies are in accordance with the Wisconsin Administrative Code, PSC § 185.3. Rule 06-30. Disconnection of Water Service Prior to Razing or Moving Buildings. Prior to razing or moving any building the party to whom a Razing or Moving Permit is issued shall request the Water Utility, in writing, to remove the meter and shall cause the water service to be disconnected and capped at the property line. If the capped water service from the property line to the connection at the water main in the public right-of-way is constructed of lead or galvanized steel, the entire water service shall be abandoned and is not permitted for reuse. Rule 06-31. To Provide a Program for Protecting the Public Water System from Contamination Due to Backflow of Contaminants Through the Water Service Connection into the Public Water System. A. Cross-Connection Prohibited. No person may establish or permit to be established or maintain or permit to be maintained any cross-connection. No interconnection shall be established whereby potable water from a private, auxiliary or emergency water supply, other than the public water supply of the Utility, may enter the supply or distribution system of the Utility, unless such private, auxiliary, or emergency water supply and the method of connection and use of such supply shall have been approved by the Utility and the State of Wisconsin Department of Natural Resources. Cross-connection shall be protected as required in Chapter SPS 382, Wisconsin Administrative Code. B. Inspections. It shall be the duty of the Utility to cause inspection to be made of all properties serviced by the Utility where cross-connection with the public water system is deemed possible. Residential properties serviced by the Utility shall be inspected on an interval matching the meter replacement schedule. All nonresidential properties serviced by the Utility shall be inspected on a two-year interval. Commercial properties of similar or lesser risk as residential properties may follow the same schedule as residential properties. The Utility shall be responsible for determining the hazard risk and the inspection schedule. The Utility may, but is not required to, perform the cross-connection inspection of residential and low hazard properties. For nonresidential properties or properties of significant hazard risk, upon notification in writing by the Utility, the property owner must, at their own expense, have the plumbing inspected for cross-connections by a State of Wisconsin Certified Cross-Connection Inspector/Surveyor or by a State of Wisconsin licensed plumber. The frequency of required inspections and re-inspections, based on potential health hazards involved, may be shortened by the Utility. The Utility shall charge fees as approved by the State of Wisconsin Public Service Commission for on-premises follow-up visits by Utility personnel for re-inspection due to customer noncompliance and for after-hours inspections or re-inspections. C. Owner Responsibility. The property owner shall be responsible for the protection of the customer's potable water system. Every person owning or occupying a premises receiving municipal water supply shall maintain such municipal water supply free from any cross connection, either by a direct or an indirect nature. The responsibilities include the elimination of, or protection from, all cross connections on their premises. The owner shall, at their own expense, install, maintain and test any and all backflow preventers on their premises in compliance with the Chapter SPS 382.41 Wisconsin Administrative Code and the Utility's Cross Connection Ordinance. The property owner shall have corrected any malfunction revealed by periodic testing of any backflow preventer on their premises. The property owner shall inform the Utility of any proposed or modified cross connections and also any existing cross connections that are not protected by an approved backflow prevention means. The property owner shall not install a by-pass around any backflow preventer unless there is a backflow preventer of the same type in the by-pass. Property owners who cannot shut down operation for testing of the backflow prevention assembly must supply additional assemblies necessary to allow testing and maintenance to take place. In the event the property owner installs potable water using fixtures, equipment or appurtenances upstream of the backflow preventer, such must have its own approved backflow prevention means. The property owner is required to follow the protection practices described in the American Water Works Association publication AWWA M-14 titled "Recommended Backflow Prevention and Cross Connection Control," United States Environmental Protection Agency publication titled "Cross Connection Control Manual," Chapters SPS 381-384 Wisconsin Administrative Code, and the Utility's Cross Connection Control Ordinance, unless the Utility requires or authorizes other means of protecting the potable water systems. Other required or authorized means will be subject to prior approval of the Utility. D. Right of Entry. Upon presentation of credentials, representatives of the Utility shall have the right of entry at any reasonable time to examine any property served by a connection to the public water system of the Utility for cross-connection. If entry is refused, such representatives may obtain a special inspection warrant under Wis. Stats. § 66.0119. Refusing to provide access shall be sufficient cause for the Utility to discontinue water service to the property, as provided under paragraph F. of this Section. E. Provision of Requested Information. The Utility may request an owner, lessee, or occupant of property served by a connection to the public water system to furnish the Utility with pertinent information regarding the piping systems on the property. Refusing to provide requested information shall be sufficient cause for the Utility to discontinue water service to the property, as provided under paragraph Subsection F. of this Section. F. Authority to Discontinue Service. The Utility is hereby authorized and directed to discontinue water service to any property wherein any connection in violation of this section exists and to take such other precautionary measures deemed necessary to eliminate any danger of contamination of the public water system. Water service shall be discontinued if the means of backflow prevention required by the Utility is not installed, tested, maintained, and repaired in compliance with this Section and Wisconsin Administrative Code NR 811 or if it is found that the means of backflow prevention required by this Section has been removed, bypassed or information requested in Section E. is not provided. Water service shall be discontinued only after reasonable notice and opportunity for hearing under Wis. Stats. ch. 68, except as provided in Subsection G. of this section. Water service to such property shall not be restored until the unprotected cross-connection has been eliminated or requested information is not provided. G. Emergency Discontinuance of Service. If it is determined by the Utility that an unprotected cross-connection or an emergency endangers public health, safety, or welfare and requires immediate action, service may be immediately discontinued. A written notice to the effect must be delivered to the customer premises. The owner, lessee, or occupant shall have an opportunity for hearing under Wis. Stats. ch. 68, within ten (10) days of such emergency discontinuance. Such hearing shall be before the Board of Water Commissioners and shall conform to all existing due process requirements. H. Reconnection of Service. Water service to any property discontinued under the provisions of this Section shall not be restored until the cross-connection has been eliminated or a backflow prevention device is approved by the Utility has been installed in compliance with the provisions of this section. The Utility shall charge fees as approved by the State of Wisconsin Public Service Commission for the reconnection of the water service. I. Additional Protection. In the case of premises having (a) internal cross-connection that cannot be permanently corrected or controlled, or (b) intricate plumbing and piping arrangements or where entry to all portions of the premises is not readily accessible for inspection purposes, making it impracticable or impossible to ascertain whether or not dangerous cross-connections exist, the public water system shall be protected against backflow from the premises by installing an approved backflow preventer in the service line. In the case of any premises where there is any material dangerous to health that is handled in such a manner that, in the opinion of the Utility, could create an actual or potential hazard to the public water system, the public water system shall be protected by an approved air-gap separation or an approved reduced-pressure principle backflow preventer. Examples of premises where these conditions will exist include sewage treatment plants, hospitals, mortuaries, plating plants, and car wash establishments. In the case of any premises where, in the opinion of the Utility, an undue health threat is posed because of the presence of toxic substances, the Utility may require an approved air gap at the service connection to protect the public water system. This requirement will be at the discretion of the Utility. Rule 06-32. Fire Hydrants. No person, except an employee of the Water Utility, Public Works Department or Fire Department, in the course of their employment, or person obtaining a permit from the Water Utility, shall open and take water from a Water Utility owned fire hydrant or in any way interfere with, injure, break, or deface any fire hydrant belonging to the Water Utility. No building, structure, tree, pole, post, sign, or any other obstruction shall be placed, located or maintained within a five-foot radius of any fire hydrant connected to the Water Utility water supply system. Any unauthorized person taking water from a fire hydrant shall pay to the Water Utility a Hydrant Permit fee and water usage charge as payment for the water diverted from the fire hydrant in addition to any applicable civil forfeitures resulting from prosecution and conviction for a violation of this Chapter. Fire Hydrant Permit fees are authorized by the Wisconsin Public Service Commission. Rule 06-33. Fire Hydrant Maintenance. Private fire hydrant maintenance may be performed by Water Utility employees upon a signed agreement between the Water Utility and property owner. Charges for private fire hydrant maintenance shall be established by the Water Utility. Rule 06-34. Fire Protection. The Water Utility, as a public service, may install and maintain fire hydrants to be used for Public Fire Protection. The fire hydrants shall be installed in accordance with the National Board of Fire Underwriters recommendations. However, the Water Utility does not assume liability for any failure to act in this regard as the performance of such service is not guaranteed within any particular time frame or as to any particular location. Rule 06-35. Testing of Water. The Wisconsin Department of Natural Resources has approved and authorized the Water Production Laboratory of the Water Utility to test water to determine if it is safe for domestic purposes. Any water connection larger than two (2) inches shall be flushed by the installer and tested by the Water Utility laboratory and be certified with two (2) consecutive bacteriologically safe samples at least twenty-four (24) hours apart prior to use for any purpose. A water line pressure test shall be made only after bacteriologically safe samples have been obtained. Preparation for flushing and testing shall consist of providing a flushing assembly at the end of the installed line before any other piping is connected. The flushing assembly shall consist of a two-inch minimum connection to the end of the line, a three-quarter-inch female pipe tee for a test faucet, a test faucet and necessary hose to discharge the flushing water in to a drain. The size of the hose shall be one and one-half (1½) inches for water main sizes smaller than eight (8) inches and hose lengths two hundred (200) feet or less. All others require hoses two and one half (2½) inches in diameter. Flushing shall proceed only upon approval and under the supervision of the Water Utility. All samples for newly constructed services or water mains shall be taken by Water Utility personnel. Metering of flushing water is required. Meters can be obtained at the Utility Business Office. Flushing water may only be turned off upon notification by the Water Utility that the installation has been determined to be bacteriologically safe.
(Ord. No. 23-23, § 1, 7-3-2023; Ord. No. 03-25, §§ 1, 2, 2-19-2025)
Ask a question about Kenosha law
Corpus searches the Kenosha sections it holds and shows the ones that match, with their citations. Free, no sign-in.
