For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 32.08 — Wastewater Discharge Regulations

Code of General Ordinances of the City of Kenosha, Wisconsin (Codified through Ordinance No. 33-26, adopted September 9, 2026. (Supp. No. 11, Update 2)) · Kenosha Code of General Ordinances § 32.08

Corpus is an independent public-information project, not the official City of Kenosha website. Stable reference: corpuslaw.us/code/7852a41f-04e1-457d-a276-85fd53b0efd2

32.08. - Wastewater Discharge Regulations.

Rule 08-01. General. These regulations set forth uniform requirements for dischargers discharging into the wastewater collection facilities of the Water Utility and enables said Water Utility to comply with the Clean Water Act, as amended, 33 U.S.C. 1251, et seq. and the Pretreatment Regulations, 40 CFR Part 403. This Section also allows the POTW to operate pursuant to legal authority enforceable in Federal, State, and local courts, which authorizes or enables the POTW to apply and to enforce the requirements of Sections 307(b) and (c), and 402(b)(8) of the Act and any regulations as hereafter provided for. The objectives of this Section are as follows: B. To prevent the introduction of discharges into the wastewater collection and treatment facilities which could cause injury thereto, not amenable to removal, or could contaminate sludge; C. To provide for the equitable distribution of the costs and expenses of the system and of operating an industrial wastewater pretreatment program through the granting of Wastewater Discharge Permits. D. To provide for the regulation and monitoring of dischargers discharging into the wastewater collection facilities through the issuance of permits and enforcement of general regulations. These regulations apply to all wastewater discharged into the Water Utility's wastewater collection system and/or treated at the Water Utility's wastewater treatment facilities. Rule 08-02. Discharge to the Wastewater Collection Facilities. Rule 08-02(01). Unpolluted Waters Prohibited in Sanitary Sewers. No person shall discharge or cause to be discharged any unpolluted waters into the wastewater collection facilities. Unpolluted waters may only be discharged into storm sewers and such other outlets as permitted by law. Rule 08-02(02). Downspouts and Sump Pumps Discharge Prohibited. No downspout or sump pump of any house, building, structure, or outlet of any cistern or drain shall be connected to or discharged to the wastewater collection facilities. In the event of such a connection, the Water Utility shall provide the owner or occupier of the violating property with a written notice to permanently disconnect the unlawful connection, within thirty (30) days. It shall be unlawful for any person to fail to promptly comply with such order, unless an extension of time has been requested from and granted by the Water Utility prior to the date specified in an order to disconnect. (Charges for unlawful storm water discharge—See Rule 07-07 (10).) Rule 08-02(03). Wastewater Prohibited in Storm Water Collection Facilities. No person shall discharge, or cause to be discharged, any wastewater into the storm water collection facilities, unless specifically authorized to do so under the terms of a specific WPDES Permit. Rule 08-02(04). Prohibited Wastewater. No person shall discharge or cause to be discharged any of the following, measured at the point of discharge, into the wastewater collection facilities. A. Gasoline, benzene, naptha, fuel oil, or other flammable or explosive liquids, solids or gases, which by reason of their nature or quantity may be sufficient, either alone or by interaction with other substances to create a fire or explosion hazard or be injurious to the POTW. Other elements and compounds are included, but are not limited to, wastestreams with a closed cup flashpoint of less than one hundred forty (140) degrees Fahrenheit or sixty (60) degrees Celsius using the test methods specified in 40 CFR 261.21. B. Wastewater containing nonconventional pollutants; or solids, liquids, or gases of any property which, in sufficient quantity, either singly or by interaction with other wastes, may injure the system or contaminate the sludge, or cause air pollution above allowable levels. C. Wastewater discharged with a pH of less than 5.5 or greater than 10.0 or which may cause corrosive structural damage to the wastewater collection or treatment facilities. D. Solids which cannot penetrate a Tyler designation twenty (20) mesh screen or viscous substances in quantities which may injure the system or contaminate the sludge. E. Heat in amounts which will inhibit biological activity in the POTW resulting in interference, but in no case heat in such quantities that the temperature at the POTW exceeds one hundred four (104) degrees Fahrenheit (forty (40) degrees Celsius). F. Wastewater containing more than one hundred (100) mg/l of petroleum oil, nonbiodegradable cutting oils, or products of mineral oil origin, or otherwise in amounts that will cause interference or pass through. G. Garbage that has not been shredded so as to comply with Rule 08-02(04)D. (Garbage grinders may be connected to sanitary sewers from homes, hotels, institutions, restaurants, hospitals, catering establishments, or similar places where garbage originates from the preparation of food.) H. Wastewater containing chromium, copper, zinc, and other nonconventional and priority pollutants to such degree that they are in concentrations exceeding levels specified within this Section or within applicable Federal and State laws, rules and regulations. Categorically regulated wastestreams shall be measured at the point of discharge from the regulated process, a discharge from a pretreatment process, or at the point of discharge to the wastewater collection facilities when the use of the combined wastestream formula has been approved. I. The following substances in excess of the limit below provided: Parameter | Consecutive 4-Day Average Limit (mg/L) | Daily Maximum Limit (mg/L) Cadmium | 1 | 1.75 Chromium (Total)* | 10 | 15 Copper | 1.5 | 2.63 Lead | 10 | 15 Mercury | 0.001 | 0.00175 Nickel | 3 | 5.25 Silver | 3 | 5.25 Zinc | 10 | 15 Cyanide | 0.96 | 1.7 *Hexavalent chrome shall be reduced to trivalent chrome before discharge to the wastewater collection facilities or be eliminated from the wastewater stream. Should National Categorical Pretreatment Standards (NCPS) provide for more stringent limitations, the NCPS shall prevail. J. Wastewater containing substances which are not amenable to treatment or reduction by the wastewater treatment processes employed by the wastewater treatment facility, or which are amenable to treatment only to such degree that the wastewater treatment facility effluent cannot meet the requirements of the Federal and State laws, rules, and regulations. K. Wastewater which, by interaction with other wastewater, forms and releases pollutants that result in the presence of toxic gases, vapors, fumes, or suspended solids which may injure the system or enter the POTW in a quantity that may adversely affect worker health or contaminate the sludge. L. Pollutants, including oxygen demanding pollutants (BOD, etc.) released in a discharge at a flow rate and/or pollutant concentration that will cause interference with the POTW. M. Substances which exert or cause: 1. A volume or concentration of wastewater consisting of slugs in sufficient quantities to injure the system or contaminate the sludge. 2. Concentrations of inert suspended solids, or inert dissolved solids, sufficient to injure the system or contaminate the sludge. N. No person shall introduce or cause to be introduced into the POTW any pollutant or wastewater which pass through or interfere with the operation or performance of the POTW or sanitary sewer. Rule 08-02(05). Dilution of Discharge Prohibited. No person discharging into the wastewater collection facilities shall increase the use of potable or process water or mix separate wastewaters for the purpose of diluting prohibited wastewater as a partial or complete substitute for pretreatment or to otherwise avoid compliance with or circumvent this Section. Rule 08-02(06). Notice of Accidental Discharge of Prohibited Wastewater. Any person who does not hold a Wastewater Discharge Permit who discharges or causes to be discharged prohibited wastewater into the wastewater collection facilities shall immediately orally notify the Water Utility thereof. Such notice shall include the date, time, place, and cause of such discharge, the nature, volume, and concentration of such discharge and any corrective action taken. The oral notice must be reduced to writing and submitted to the Water Utility within ten (10) days of an accidental discharge. Rule 08-03. Wastewater Discharge Permits. Rule 08-03(01). Dischargers Required to Obtain a Permit. The following Dischargers shall be required to obtain a Wastewater Discharge Permit prior to and as a condition of any wastewater discharge into the wastewater collection facilities: A. Industrial Dischargers currently discharging to the wastewater collection facilities. B. Industrial Dischargers not currently discharging to the wastewater collection facilities who intend to discharge within ninety (90) days. C. Haulers. D. Municipalities. Rule 08-03 (02). Procedures for Application. Applications for Wastewater Discharge Permits shall be made on Water Utility supplied forms. It shall be unlawful for any person to intentionally file an incomplete or inaccurate application. A Wastewater Discharge Permit will not be processed or issued until a complete and accurate application is filed. The application for a Wastewater Discharge Permit must be signed by an authorized representative of the industrial user, municipality or hauler, and must contain the following information prior to being processed: A. The name, address and location of the industrial discharger, hauler or municipality and the location of the point of discharge if different from the business address. B. The SIC number of the facility. C. The probable constituents and characteristics of wastewater that will be discharged. D. The expected time and duration of discharges. E. The expected average daily wastewater discharge rates, in gallons per day, including seasonal variations, if any. F. Site plans, floor plans, mechanical and plumbing plans, and details which show all sanitary sewers, sanitary sewer connections, inspection manholes, sampling chambers, and appurtenances by size, location and elevation. G. General description of activities, facilities, and plant processes on the premises, including all materials that may be discharged. H. A listing of each product produced by type, expected quantity, process or processes, and anticipated rate of production. I. The type and quantity of raw materials utilized, which may be discharged. J. Whether or not the Facility will be in compliance with this Section on a consistent basis. Rule 08-03(03). Amendments to Applications. An industrial discharger, municipality, or hauler, must submit an amended application for a Wastewater Discharge Permit within thirty (30) days following any material change in the information required and previously submitted on an application form, and thirty (30) days prior to the following: A. Change in the characteristics and constituents of wastewater, B. Change in the volume of wastewater discharged by twenty (20) percent or more, or C. Change in the operations or processes utilized by the discharger. An amended application will be processed the same as if it were an original application. This rule does not apply to temporary variations in production schedules. Rule 08-03(04). Insufficient Information. Where an application for a Wastewater Discharge Permit contains insufficient or inaccurate information, the Water Utility may require more complete and accurate information. Applicants shall be provided thirty (30) days from the date of receipt of written notice of an incomplete or inaccurate application in which to furnish more complete or accurate information. Rule 08-03(05). Permit Approval. Ninety (90) days after a fully completed and accurate application is submitted for a Wastewater Discharge Permit, such permit shall be issued in accordance with the provisions of this Section, which will specify wastewater which is totally prohibited, place limits on the constituents and characteristics of wastewater, and provide for the pretreatment of certain wastewater prior to its discharge to the wastewater collection facilities. Wastewater Discharge Permits are granted by the Board. Rule 08-03(06). Permit Terms, Conditions and Limitations. The following terms, conditions, and limitations shall be specified in Wastewater Discharge Permits: A. Effluent limitations based on prohibited discharge standards, categorical pretreatment standards, local limits and state and local law. B. Limitations on the average and maximum rate and time of discharge and/or requirements for flow regulation and equalization. C. Requirements for inspection and sampling. Cost incurred by the Water Utility for sample collection and analysis shall be billed to the discharger. D. Special conditions imposed by the Water Utility under particular circumstances, including sampling locations, frequency of sampling and monitoring, the number and types of analytical tests, reporting schedule, and special technical reports or discharge reports. The special conditions imposed shall be reasonable and necessary to carry out the objectives of this Section. In each case, at the discharger's written request, the Water Utility may provide to the discharger a full and complete explanation of the reason for the special condition(s). E. Requirements for reporting and action plans in the event of an accidental discharge of prohibited wastewater. Dischargers which have a potential for an accidental discharge of prohibited wastewater shall be required to develop a written plan designed to prevent accidental discharges of prohibited wastewater, and in the event of such accidental discharge, to mitigate potential damages which could be caused thereby. Such plan shall include a provision that dischargers place signs in conspicuous places on their premises advising officers, employees and agents thereof of the procedure to be utilized to report a discharge of prohibited wastewater to the Water Utility. F. Requirements for pretreatment. Where pretreatment is required, the discharger shall submit a plan therefor to the Water Utility. Such plan may not be implemented until approved by the State of Wisconsin and the Water Utility. Effluent limitations will be based on applicable Federal and State pretreatment standards and this Chapter. It shall be unlawful for a discharger to fail to obey an order for pretreatment for any phase of the implementation of pretreatment. Pretreatment shall be at the sole cost and expense of the discharger. G. Provisions for self-monitoring, sampling, reporting, notification, and record keeping requirements, including an identification of the pollutants to be monitored, sampling location, sampling frequency, and sample type, based on Federal and State laws, rules and regulations and this Chapter. Installation, operation, and maintenance of the sampling facilities shall be at the cost and expense of the discharger and shall be subject to the approval of the Water Utility. Access to sampling sites, processes that discharge wastewater, pretreatment facilities and wastewater self-monitoring records shall be granted to the Water Utility and its authorized representatives. H. Requirements to control slug discharges, if determined by the POTW to be necessary. If the POTW determines that a slug control plan is needed, the industrial user must develop a plan with the following elements as deemed necessary by the POTW: 1. A description of discharge practices, including non-routine batch discharges; 2. A description of stored chemicals; 3. Procedures for immediately notifying the POTW of slug discharges, including any discharge that would violate a prohibition in Rule 08-02(04), with procedures for a subsequent written notification within five (5) days; 4. Any procedures deemed necessary by the POTW to: a. Prevent accidental spills; b. Inspect and maintain storage areas; c. Handle and transfer materials; d. Control loading and unloading operations; e. Control plant site run-off; and f. Train workers. 5. Any procedures deemed necessary by the POTW for building containment structures or equipment; 6. Any procedures deemed necessary by the POTW to contain toxic organic pollutants, including solvents; 7. Any procedures and equipment deemed necessary by the POTW for emergency response; and 8. Any practices deemed necessary by the POTW to limit the damage suffered by the treatment plant or the environment after a slug discharge. I. Provisions of discharge by haulers. The permit will identify each vehicle and the license number thereof which will discharge into the wastewater collection facilities. Permits shall be nonassignable and nontransferable, except in the case of replacement of a vehicle for which a permit has been issued. The Water Utility may require a bond to guarantee payment of all fees and charges. The time and place of discharge into the wastewater collection facilities will be designated by the Water Utility. The Water Utility may impose such conditions as it deems necessary on any permit granted. Haulers must carry public liability and motor vehicle insurance in an amount no less than one million dollars ($1,000,000.00) covering loss through death, injury and property damage caused in any way or manner by an action, or omission, of a hauler or the employees or agents thereof. A Certificate of Insurance must be furnished to the Water Utility with the application. Haulers shall post a bond for five thousand dollars ($5,000.00) to indemnify and hold harmless the Water Utility against injury to the system, contamination of the sludge, and costs associated with the correction of upsets in process at the wastewater treatment facility. Permit holders may not discharge prohibited wastewater into the system unless their permit so authorizes, and then only to the extent permitted. Haulers shall pay a service charge as determined by the concentration of the waste pursuant to Rule 07-07(05) of this Chapter, or as determined by agreement with the Water Utility. All trucked or hauled wastewater must be discharged at the point(s) designated by the Water Utility. J. A statement that dischargers discharging on the effective date of this rule shall comply with said Section where it is stricter than Federal or State laws, or regulations, within fifteen (15) days after the effective date of said Section. If compliance with Section 32.08 is not met within the allotted fifteen (15) days, stepped enforcement actions will be initiated. K. A statement of applicable civil and criminal penalties for violation of this Chapter, pretreatment standards and requirements, and any applicable compliance schedule. L. Compliance by existing industrial sources with categorical pretreatment standards shall be within three (3) years of the date the standard is effective unless a shorter compliance time is otherwise specified. Existing sources which become industrial users subsequent to promulgation of an applicable categorical pretreatment standard shall be considered existing industrial users. M. New sources shall install and have in operating condition, and shall "start-up" all pollution control equipment required to meet applicable pretreatment standards before beginning to discharge. Within the shortest feasible time (not to exceed ninety (90) days), new sources must meet all applicable pretreatment standards. Rule 08-03(07). Equivalent Limits. When the limits in a categorical pretreatment standard are expressed only in terms of mass of pollutant per unit of production, the POTW may convert the limits to equivalent limits expressed either as mass of pollutant discharged per day or effluent concentration. The POTW shall calculate equivalent mass-per-day limitations by multiplying the limits in the standard by the industrial user's average rate of production. This average rate of production shall be based upon a reasonable measure of the industrial user's actual long-term daily production, such as the average daily production during a representative year. New sources shall use projected production in place of actual production. Any industrial user operating under a control mechanism incorporating equivalent mass or concentration limits shall notify the POTW within two (2) business days after the user has a reasonable basis to know that the production level will significantly change. Rule 08-03(08). Permit Duration. All Wastewater Discharge Permits shall be issued for four (4) years, or as determined by the Board, subject to conditions of this Section. Rule 08-03(09). Limitations on Permit Assignment and Transfer. A Wastewater Discharge Permit is issued to a specific industrial discharger, municipality, or hauler for a specific operation and is not valid for operations not described in the application, is not assignable to another discharger, or transferable to any other location without prior notification and approval from the Water Utility. Rule 08-03(10). Permit Amendments by Issuer. The Water Utility may amend any Wastewater Discharge Permit issued to a discharger subject to the discharger being given an opportunity to be heard, for the purpose of correcting any errors or omissions made by the Water Utility and to incorporate revised limitations on prohibited wastewater required by law. A compliance schedule shall be issued if an industry cannot meet any new or modified requirements on their effective date, unless prohibited by Federal or State law, rule or regulation. Rule 08-03(11). Extensions of Permit Time Schedules. Whenever any industrial discharger, municipality, or hauler believes that any time schedule contained in a Wastewater Discharge Permit is unreasonable under the circumstances, such discharger may request, in writing, an extension of time to meet such schedule prior to the expiration of any such time limit. Time extensions may be given after the fact, but the discharger is subject to the penalties herein provided for failure to meet such time schedule. Rule 08-03(12). Opportunity for Hearing Relative to Permit Conditions and Limitations. Any discharger, within thirty (30) days of the granting of a Wastewater Discharge Permit, may file with the Water Utility a request to be heard relative to the application of any permit conditions and limitations. An opportunity to be heard will be provided before the General Manager of the Water Utility within ten (10) days of the receipt thereby of a request for hearing. Rule 08-04. Reporting and Monitoring Requirements for Holders of Wastewater Discharge Permits. Rule 08-04(01). NCPS Incorporated by Reference. The NCPS, and all amendments which may be made thereto, are incorporated herein by reference. Rule 08-04(02). Application of Rule 08-04. Rule 08-04 is applicable to all holders of Wastewater Discharge Permits where NCPS are applicable. Rule 08-04(03). Notice to Holders of Wastewater Discharge Permits. Where applicable, the Water Utility shall provide written notification to all holders of Wastewater Discharge Permits, that NCPS are applicable, as follows: A. At the time of granting a Wastewater Discharge Permit, such notice will be provided within such permit, and limitations provided for by NCPS will be a term and condition of such permit. B. At such time as the Water Utility is aware of new NCPS. C. At such time as the Water Utility is aware that a holder of a Wastewater Discharge Permit is subject to NCPS. However, lack of notice furnished by the Water Utility will not relieve the holder of a Wastewater Discharge Permit of their obligation to timely comply with NCPS. Rule 8-04(04). Baseline Monitoring Report (BMR) Filing Requirements. All Baseline Monitoring Reports shall be filed with the Water Utility as follows: A. Any industrial discharger subject to NCPS that plans to connect to the wastewater collection facilities shall file a BMR with the Water Utility no later than sixty (60) days prior to discharging any wastewater to the collection facilities. B. New industrial dischargers subject to NCPS shall file a BMR with the Water Utility no later than ninety (90) days prior to the initial discharge of wastewater to the collection facilities. C. An existing discharger that becomes an industrial discharger subject to NCPS after promulgation of an applicable pretreatment standard shall file a BMR with the Water Utility within one hundred eighty (180) days following the effective date of the categorical standard. Rule 08-04(05). Required Contents of BMR. A BMR shall be on a Water Utility form and shall contain the following information respecting industrial dischargers subject to NCPS: A. Identifying Information. The name and address of the discharger, and the names of the persons who own and operate the facility from which there will be a discharge of wastewater into the wastewater collection facilities; and the SIC of the operator. B. Permits. A listing of any environmental control permits held or applications pending. C. Description of Operations. A description of the unit processes that the facility plans to use in production. D. Production. A description of the nature and average rate of production. E. Points of Discharge. A process schematic diagram indicating points of wastewater discharge. F. Pretreatment Equipment. Any pretreatment equipment employed at the facility. G. Flow Measurement. The discharger shall submit information showing the measured average daily and maximum daily flow, in gallons per day, to the POTW from all wastestreams. H. Measurement of Pollutants. The discharger shall identify the pretreatment standards applicable to each regulated process. Sampling and analysis shall be done on wastestreams that are regulated and results shall identify the nature and concentration of regulated pollutants. Sampling and analysis shall be performed pursuant to 40 CFR 403.12(b)(5)(ii)—(viii).Where alternative sampling is authorized by the POTW under Rule 08-04(10), the samples shall be representative of the discharge and the decision to allow alternative methods shall be documented in the industrial user's file. I. Certification. A statement, reviewed by an authorized representative of the discharger and certified by a qualified professional, indicating whether pretreatment standards are being met on a consistent basis, and, if not, whether additional operation and maintenance and/or additional pretreatment is required for the discharger to meet the pretreatment standards and requirements. Rule 08-04(06). Compliance Date Report. Within ninety (90) days following the date for final compliance with applicable categorical pretreatment standards or in the case of a new source following commencement of the introduction of wastewater into the POTW, any industrial discharger subject to NCPS shall submit to the Water Utility a report containing the information described in 40 CFR 403.12(b)(4)—(6). For all other industrial dischargers subject to NCPS expressed in terms of allowable pollutant discharge per unit of production, this report shall include the discharger's actual production during the appropriate sampling period. This report shall be signed by an authorized representative of the discharger and certified by a qualified professional. Rule 08-04(07). Periodic Reports on Continued Compliance. Any industrial discharger subject to NCPS shall submit to the Water Utility a report indicating the nature and concentration of pollutants in the effluent which are limited by categorical pretreatment standards. This report shall also include a record of measured or estimated average and maximum daily flows for the reporting period for the discharge reported in Rule 08-04(05)G. Compliance reports shall be submitted to the Water Utility during the months of July and January, unless required more frequently by the Water Utility. Flow shall be reported on the basis of actual measurement, except that where cost or feasibility considerations justify, the Water Utility may accept reports of average and maximum flows estimated by verifiable techniques. Rule 08-04(08). Pretreatment Reporting Requirements. Industrial dischargers subject to NCPS shall comply with the following reporting requirements: A. All dischargers shall notify the POTW immediately of all discharges that could injure the system or contaminate the sludge, including any slug loadings by the discharger. B. The reports required in Rule 08-04(07) shall be based upon data which is representative of conditions occurring during the reporting period. Appropriate sampling and analysis shall be performed during the period covered by the reporting period. The POTW shall require such frequency of monitoring as necessary to assess and assure compliance by discharger, with applicable pretreatment standards and requirements. Sampling and analysis may be performed by the POTW instead of the discharger. When the POTW collects all of the information required for a report, the POTW will not require the discharger to submit the report. C. If a discharger subject to the reporting requirement in Rule 08-04(07) monitors any pollutant more frequently than required by the POTW, using the procedures prescribed in this Section, the results of this monitoring shall be included in the report required in Rule 08-04(07). D. The POTW may authorize a monitoring waiver for individual pollutants for an industrial user subject to a categorical standard if the user has demonstrated through sampling and other technical factors as deemed necessary by the POTW that the pollutant is neither present nor expected to be present in the discharge, or is present only at background levels from intake water and without any increase in the pollutant due to activities of the industrial user. This authorization is subject to the following conditions: 1. The POTW may authorize a waiver where a pollutant is determined to be present solely due to sanitary wastewater discharged from the facility provided that the sanitary wastewater is not regulated by an applicable categorical standard and otherwise includes no process wastewater. 2. The monitoring waiver is valid only for the duration of the effective discharge permit, but in no case longer than five (5) years. The user shall submit a new request for the waiver before the waiver may be granted for each subsequent discharge permit or five-year period. 3. In making a demonstration that a pollutant is not present, the industrial user shall provide data from sampling of the facility's process wastewater prior to any treatment present at the facility that is representative of all wastewater from all processes. The request for a monitoring waiver shall include the certification statement and be signed in accordance with Wisconsin Administrative Code, NR 211.15(10). Non-detectable sample results may only be used as a demonstration that a pollutant is not present if the EPA approved method from 40 CFR Part 136 with the lowest minimum detection level for that pollutant was used in the analysis. 4. Any grant of the monitoring waiver by the POTW shall be included as a condition in the user's discharge permit. The reasons supporting the waiver and any information submitted by the user in its request for the waiver shall be maintained by the POTW for three (3) years after expiration of the waiver. 5. Upon approval of the monitoring waiver and revision of the user's discharge permit by the POTW, the industrial user shall certify on each report with the statement below, that there has been no increase in the pollutant in its wastestream due to activities of the industrial user: "Based on my inquiry of the person or persons directly responsible for managing compliance with the applicable pretreatment standards, I certify that, to the best of my knowledge and belief, there has been no increase in the level of [list pollutant(s)] in the wastewaters due to the activities at the facility since filing of the last periodic report." 6. In the event that a waived pollutant is found to be present or is expected to be present based on changes that occur in the user's operations, the user shall immediately comply with the monitoring requirements of the discharge permit or other more frequent monitoring requirements and notify the POTW. 7. This paragraph does not supersede certification processes and requirements established in categorical pretreatment standards, except as otherwise specified in the categorical pretreatment standard 8. Where the POTW has authorized a user subject to a categorical pretreatment standard to forego sampling for a pollutant that is not present, the POTW shall sample for the waived pollutant at least once during the term of the user's discharge permit. In the event that the POTW subsequently determines that a waived pollutant is present or is expected to be present in the industrial user's wastewater based on changes that occur in the user's operations, the POTW shall immediately begin at least annual effluent monitoring for that pollutant and inspection. E. The POTW may determine that an industrial user subject to categorical pretreatment standards is a non-significant categorical industrial user rather than a significant industrial user on a finding that all of the following conditions are met: 1. The industrial user never discharges more than one hundred (100) gallons per day of total categorical wastewater, excluding sanitary, non-contact cooling and boiler blowdown wastewater, unless specifically included in the pretreatment standard. 2. The industrial user has consistently complied with all applicable categorical pretreatment standards and requirements. 3. The industrial user never discharges any untreated concentrated wastewater. 4. The industrial user annually submits the following certification statement signed in accordance with the signatory requirements of Wisconsin Administrative Code, NR 211.15 (10) along with any additional information deemed necessary by the POTW: "Based on my inquiry of the person or persons directly responsible for managing compliance with pretreatment standards, I certify that, to the best of my knowledge and belief that during the period from [date], to [date], the facility described as [facility name] met the definition of a non-significant categorical industrial user as described in NR 211.15 (4) (d); the facility compiled with all applicable pretreatment standards and requirements during this reporting period; and the facility never discharged more than one hundred (100) gallons of total categorical wastewater on any given day during this reporting period. This compliance certification is based upon the following information: [applicable data]." 5. Where the POTW has determined that an industrial user meets the criteria for classification as a non-significant categorical industrial user in accordance with Wisconsin Administrative Code, NR 211.15(4)(d), the POTW shall evaluate, at least once per year, whether the industrial user continues to meet those criteria. F. The POTW may reduce the frequency of the reports required under Rule 08-04(07) to no less than once per year, unless required more frequently by the pretreatment standard or the department, where the industrial user meets all of the following conditions: 1. The industrial user's total categorical wastewater flow does not exceed any of the following: a. One one-hundredth (.01) percent of the design dry weather hydraulic capacity of the POTW, or five thousand (5,000) gallons per day, whichever is smaller, as measured by a continuous effluent flow monitoring device unless the industrial user discharges in batches; b. One one-hundredth (.01) percent of the design dry weather organic treatment capacity of the POTW; and c. One one-hundredth (.01) percent of the maximum allowable headworks loading for any pollutant regulated by the applicable categorical pretreatment standard for which approved local limits were developed by a POTW in accordance with Wisconsin Administrative Code, NR 211.10(3); 2. The industrial user has not been in significant noncompliance, at any time in the past two (2) years; 3. The industrial user does not have daily flow rates, production levels, or pollutant levels that vary so significantly that decreasing the reporting requirement would result in data that are not representative of conditions occurring during the reporting period; 4. The industrial user shall notify the POTW immediately of any changes at its facility causing it to no longer meet conditions of paragraph 1. or 2. Upon notification, the industrial user shall immediately begin complying with the minimum reporting requirements under Rule 08-04(07); and 5. The control authority shall retain documentation to support the determination that a specific industrial user qualifies for reduced reporting requirements under this paragraph for a period of three (3) years after the expiration of the term of the control mechanism. 6. Where the POTW has determined that an industrial user is subject to reduced reporting requirements as described in, the POTW shall inspect and sample the effluent from the industrial user at least once every two (2) years. If the industrial user no longer meets the conditions for reduced reporting, the POTW shall immediately begin sampling and inspecting the industrial user at least once a year. Rule 08-04(09). Reports from Noncategorical Significant Industrial Dischargers. The POTW shall require appropriate reporting from those significant industrial dischargers with discharges that are not subject to NCPS. Significant noncategorical industrial dischargers shall submit to the Water Utility at least once every six (6) months, in the months of July and January, a report indicating the nature, concentration, and flow of the pollutants required to be monitored by the Water Utility. These reports shall be based on sampling, and analysis performed in the period covered by the report, and performed in accordance with the techniques described in 40 CFR Part 136 and amendments thereto. Where 40 CFR Part 136 does not contain sampling or analytical techniques, or where the sampling or analytical technique described in 40 CFR Part 136 are inappropriate for the pollutants in question, or where the Administrator otherwise determines, the sampling and analysis shall be performed by using validated analytical methods or any other applicable sampling and analytical procedures, including procedures suggested by the POTW or other persons approved by the EPA Administrator. Sampling shall be conducted at the appropriate sampling location and shall be representative of conditions during the reporting period. If a user monitors any regulated pollutant more frequently than required by the POTW, the results of this monitoring shall be included in the report. This sampling and analysis may be performed by the POTW. Where the POTW itself collects all information required for the report, the noncategorical significant industrial discharger will not be required to submit the report. Rule 08-04(10). Sampling Collection and Analysis for SIUs. Sampling and analysis shall be performed to identify the concentration or mass of regulated pollutants in the discharge from each regulated process, according to the requirements of the applicable categorical pretreatment standard and the POTW. Samples shall be representative of daily operations. Grab samples shall be used for pH, cyanide, total phenols, oil and grease, sulfide and volatile organics. All other samples shall be twenty-four-hour flow proportional composites, unless time proportional or grab sampling is authorized by the POTW. Where alternative sampling is authorized by the POTW, the samples shall be representative of the discharge and the decision to allow alternative methods shall be documented in the industrial user's file. Multiple grab samples collected during a twenty-four-hour period may be composited prior to analysis provided appropriate protocols specified in Wisconsin Administrative Code, ch. NR 219, and in EPA and department guidance are followed. Rule 08-04(11). Notice of Violation/Repeat Sampling and Reporting. If sampling performed by a discharger indicates a violation, the discharger must notify the POTW within twenty-four (24) hours of becoming aware of the violation. The discharger shall also repeat the sampling and analysis and submit the results of the repeat analysis to the POTW within thirty (30) days after becoming aware of the violation, except the discharger is not required to resample if the POTW performs sampling between the discharger's initial sampling and the time when the discharger receives the results of this sampling. Rule 08-04(12). Notification of Changed Discharge. All industrial dischargers shall promptly notify the POTW in advance of any substantial change in the volume or character of pollutants in their discharge, including the listed or characteristic hazardous wastes for which the industrial user has submitted initial notification under Rule 08-04(11). Significant Industrial Users are required to notify the POTW immediately of any changes at its facility affecting the potential for a Slug Discharge. Rule 08-04(13). Hazardous Waste Notification. Any industrial discharger who commences the discharge of hazardous waste shall notify the POTW, the EPA Regional Waste Management Division Director, and State hazardous waste authorities in writing of any discharge into the POTW of a substance which, if otherwise disposed of, would be a hazardous waste under 40 CFR Part 261. Such notification must include the name of the hazardous waste as set forth in 40 CFR Part 261, the EPA hazardous waste number, and the type of discharge (continuous, batch, or other). If the industrial discharger discharges more than one hundred (100) kilograms of such waste per calendar month to the POTW, the notification shall also contain the following information to the extent such information is known and readily available to the industrial discharger: A. An identification of the hazardous constituents contained in the wastes, B. An estimation of the mass and concentration of such constituents in the wastestream discharged during that calendar month, and C. An estimation of the mass of constituents in the wastestream expected to be discharged during the following twelve (12) months. All notifications must take place no later than one hundred eighty (180) days after the discharge commences. Dischargers are exempt from the hazardous waste notification requirement during a calendar month in which they discharge fifteen (15) kilograms or less of non-acute hazardous wastes. Discharge of any quantity of acute hazardous waste as specified in 40 CFR 261.30(d) and 261.33(e) requires a onetime notification. Rule 08-04(14) Signature Requirements. The reports containing analytical data required by this section shall include a certification as defined in NR 211.15(10)(a) signed by an Authorized Representative. Rule 08-05. General Provisions Governing Dischargers Discharging to the Wastewater Collection Facilities. Rule 08-05(01). Measurement of Flow. The volume of flow used for computing service charges shall be the metered water consumption of the discharger as shown in the records of meter readings maintained by the Water Utility, except that devices for measuring the volume of wastewater discharged may be required by the Water Utility if this volume cannot otherwise be determined from the metered water consumption records. Metering devices for determining the volume of wastewater shall be approved by the General Manager of the Water Utility and installed, owned, and maintained by the discharger. Such meters, upon approval and installation, shall not be removed without the consent of the General Manager of the Water Utility. New categorical dischargers shall install, maintain, and own flow monitoring equipment for processes which generate categorical wastewater discharges. When a pretreatment system is updated or newly constructed, flow monitoring equipment shall be installed, maintained, and owned by the industrial user. Devices used for measuring flows by methods described in Section NR 218.05 shall be calibrated and the calibration rechecked at least annually using one (1) of the following methods: A. A method specified by the manufacturer of the device. B. Calculation of the flow from the dilution of chloride or other ion or substance added to the effluent stream at a fixed rate sufficiently ahead of the sampling point to ensure complete mixing, C. Measuring the volume withdrawn from or introduced into a tank or container in a known period of time, or D. In any specific instance by any other method approved by the General Manager of the Water Utility in response to a written request. Records of calibration data shall be retained for a three-year period, or for a longer period on specific request of the Water Utility. Rule 08-05(02). Sampling Manholes. A discharger which discharges wastewater in excess of normal domestic strength wastewater, including all food service facilities, and/or which discharges nonconventional pollutants, shall be required to construct and maintain one (1) or more sampling manholes to facilitate observation, measurement, and sampling of its wastewater. Sampling manholes shall be located as prescribed by or approved by the General Manager. Sampling manholes and related equipment shall be installed by the discharger at his/her cost and expense, and shall be maintained by the discharger so as to be safe, accessible, and in proper operating condition at all times. Plans for the installation and construction of sampling manholes and related equipment shall be approved by the General Manager prior to the commencement of construction or installation. This requirement shall apply to all new construction, change in occupancy, and renovation of existing facilities, and existing facilities classified as Category B Retail. Rule 08-05(03). Wastewater Sampling. Any wastewater discharged into the wastewater collection facilities shall be subject to periodic inspection by the Water Utility to determine the character and concentration thereof, without notice to the discharger. Rule 08-05(04). Grease and Oil, Sand Separators and Sand Basins. A discharger (other than cooking and/or food waste) who utilizes a garage catch basin, or grease or oil interceptor/separator which is connected to the wastewater collection facilities shall install, at its cost and expense, a sampling manhole on the sewer lateral. The manhole shall be located outside of the building, on private property and, if possible, accessible by a van/truck. The design of the manhole shall be as shown in "Standard Specifications for Sewer and Water Construction in Wisconsin" (latest edition) or as approved by the General Manager. Rule 08-05(05). Monitoring of Municipalities. Municipalities other than the City of Kenosha shall monitor their wastewater and report their findings as to the wastewater volume, BOD, suspended solids, phosphorus, and oil at the cost and expense of the municipality, as directed by the General Manager. Metering stations may be required by the General Manager to be installed and maintained at the cost and expense of the municipality. The General Manager shall have the right to install flow monitoring and sampling equipment to check the results reported by a municipality, and in the event of a dispute or conflict, the findings and determinations of the Water Utility shall control, all in accordance with the municipality's Wastewater Discharge Permit. Rule 08-05(06). Analysis. All measurements, testing and analysis shall be performed in accordance with 40 CFR Part 136 and amendments thereto. Where 40 CFR Part 136 does not contain sampling or analytical techniques for the pollutant in question, or where the Administrator determines that the Part 136 sampling and analytical techniques are inappropriate for the pollutant in question, sampling and analysis shall be performed by using validated analytical methods or any other applicable sampling and analytical procedures, including procedures suggested by the POTW or other parties, as approved by the Administrator. Sampling method, location, time, duration and frequency are determined on a case-by-case basis, subject to the approval by the Water Utility. Rule 08-05(07). Confidential Information. Information and data obtained by the Water Utility pursuant to this Section with respect to the nature and frequency of wastewater discharges shall be available to the public or other governmental agencies, without restriction, unless the discharger specifically requests confidentiality and is able to satisfactorily demonstrate that the release of such information would divulge information, processes, or methods of production entitled to protection as trade secrets. When the Water Utility grants a request for confidentiality, the portions of a report which are confidential shall not be made available for inspection to the public, but shall be made available, upon written request, to governmental agencies for uses related to this Section. The National Pollutant Discharge Elimination System (NPDES) Permit, and Wisconsin Pollutant Discharge Elimination System (WPDES) Permit shall also be available for use by any party involved in judicial or administrative review or enforcement proceedings involving the discharger furnishing the report. Wastewater constituents and characteristics are not recognized as confidential information. Rule 08-05(08). Bypass. Bypass is prohibited, and the POTW may take enforcement action against an industrial user for a bypass, unless: A. The bypass was unavoidable to prevent loss of life, personal injury, or severe property damage; B. There were no feasible alternatives to the bypass, such as the use of auxiliary treatment facilities, retention of untreated wastes, or maintenance during normal periods of equipment downtime. This condition is not satisfied if adequate backup equipment should have been installed in the exercise or reasonable engineering judgment to prevent a bypass which occurred during normal periods of equipment downtime or preventative maintenance; and C. The industrial user submitted notices as required under this rule. If an industrial user knows in advance of the need for a bypass, it shall submit prior notice to the POTW, at least ten (10) days before the date of the bypass, if possible. An industrial user may allow any bypass to occur which does not cause pretreatment standards or requirements to be violated, but only if it also is for essential maintenance to assure efficient operation. An industrial user shall submit oral notice of an unanticipated bypass that exceeds applicable pretreatment standards to the POTW within twenty-four (24) hours from the time it becomes aware of the bypass. A written submission shall also be provided within five (5) days of the time the industrial user becomes aware of the bypass. The written submission shall contain a description of the bypass and its cause; the duration of the bypass, including exact dates and times, and if the bypass has not been corrected, the anticipated time it is expected to continue; and steps taken or planned to reduce, eliminate, and prevent reoccurrence of the bypass. The POTW may approve an anticipated bypass, after considering its adverse effects, if the POTW determines that the user will meet the three (3) conditions listed above in 08-05(08)A., B., and C. Rule 08-05(09). Upset. An upset shall constitute an affirmative defense to an action brought for noncompliance with pretreatment standards if the requirements of the next paragraph are met. A. An industrial user who wishes to establish the affirmative defense of upset shall demonstrate, through properly signed, contemporaneous operating logs, or other relevant evidence that: 1. An upset occurred and user can identify the cause(s) of the upset. 2. The facility was at the time being operated in a prudent and workmanlike manner and in compliance with applicable operation and maintenance procedures. 3. The user has submitted the following information to the POTW within twenty-four (24) hours of becoming aware of the upset (if this information is provided orally, a written submission must be provided within five (5) days): a. A description of the discharge and cause of noncompliance. b. The period of noncompliance, including exact dates and times or, if not corrected, the anticipated time the noncompliance is expected to continue. c. Steps being taken and/or planned to reduce, eliminate and prevent recurrence of the noncompliance. 4. In any enforcement proceeding, the user seeking to establish occurrence of an upset shall have the burden of proof. 5. The user shall control production or all discharges to the extent necessary to maintain compliance with pretreatment standards upon reduction, loss, or failure of its treatment facility until the facility is restored or an alternative method of treatment is provided. This requirement applies in the situation where, among other things, the primary source of power of the treatment facility is reduced, lost or fails. Rule 08-07. Reassignment of Dischargers. The General Manager will reassign dischargers into appropriate service charge categories where Water Utility records indicate facts supporting such a change. Dischargers will be given an opportunity to be heard on the proposed action before it becomes effective. Rule 08-08. Enforcement of Wastewater Discharge Permit. Rule 08-08(01). Written Notice of Violation. Any discharger in violation of a Wastewater Discharge Permit issued to it, shall be served with a written notice stating the nature of the violation and the action proposed to be taken by the Water Utility, in response to such violation. Rule 08-08(02). Administrative Order(s). The General Manager shall have the following courses of action as options which may be taken, jointly or severally, in response to a violation of a Wastewater Discharge Permit: A. To issue an order to immediately cease the unlawful conduct identified in a notice of violation. B. To issue an order to cease the unlawful conduct identified in a notice of violation within a specified period of time. C. To pursue penalties and legal remedies as provided in Section 32.11. D. To make a claim for damages occasioned by injury to the system or contamination of the sludge. E. To suspend or revoke a Wastewater Discharge Permit. F. To commence an action at law or in equity in the State or Federal Courts for a declaratory judgment, monetary damages, and/or a temporary or permanent injunction. G. To commence an action at law for a court imposed compliance schedule. Rule 08-08(03). Opportunity for and Purpose of Hearing. The notice of violation shall provide the discharger with an opportunity for a hearing prior to enforcement action being taken. Such notice shall provide a time within which the discharger may request a hearing, which time limit shall be reasonable under the circumstances. Following a request for a hearing, a hearing shall be held before the General Manager and the violator shall be notified, in writing, of the time, date and place thereof. The purpose of such hearing shall be to determine the existence of mitigating factors, if any, and to determine the factual basis underlying the alleged violation. The failure to make a timely, written request for a hearing shall constitute a waiver of the right to such hearing. However, in the event of an emergency, an order under Rule 08-08(02)A. may be issued without a written notice and prior hearing, provided that such written notice and hearing are provided as soon as possible following the issuance of said order. Rule 08-08(04). Written Determination. Within ten (10) days following the hearing, or in the absence of a timely request for a hearing, within ten (10) days following the last day on which a hearing could have been requested, a written determination report shall be made. Rule 08-08(05). Grounds for Suspension, Revocation, or Nonrenewal of Wastewater Discharge Permit. The General Manager of the Water Utility may commence an administrative proceeding, upon written notice, and an opportunity to be heard, to seek the suspension, revocation or nonrenewal of any Wastewater Discharge Permit should a discharger: A. Fail to factually report to the Water Utility the constituents and characteristics of its wastewater discharge. B. Fail to promptly report to the Water Utility any violation by it of this Section or of any order promulgated under authority of this Section or any violation of any permit it may hold issued pursuant to this Section. C. Fail to promptly report to the Water Utility any significant change in the constituents and characteristics of its wastewater discharge. D. Fail to provide to the Water Utility reasonable access to its premises for inspection, sampling and monitoring purposes. E. Fail to abide by the terms and conditions of this Section, any order promulgated under authority of this Section, any permit issued pursuant to this Section or any court order enforcing this Section and orders promulgated under its authority. F. Fail to provide accurate and truthful information and statements to the Water Utility. G. Attempt to or tamper with any sampling, or monitoring equipment or with the analysis or reports required by this Chapter. H. Fail to timely file an amended permit application where one (1) is required by this Section. Rule 08-09. Service of Notices, Findings, and Determinations. Service of notices, findings, and determinations provided for in this Section shall be by personal service or by Certified Mail with Return Receipt. Notices to the Water Utility shall be served at or delivered to the Water Utility Business Office. Rule 08-10. Procedures for Review. Any discharger, permit applicant, or permit holder adversely affected by any decision, action or determination made by the General Manager of the Water Utility interpreting or implementing the provisions of this Section or of any permit issued herein, may file with the General Manager of the Water Utility a written request for reconsideration within ten (10) days of the date of such decision, action, or determination, setting forth in detail the facts and arguments supporting the request for reconsideration. The General Manager of the Water Utility shall render a decision on the request for reconsideration, in writing, within fifteen (15) days of receipt of the request. If the decision on the request for reconsideration made by the General Manager of the Water Utility is unsatisfactory to the party requesting the reconsideration, then such party may, within ten (10) days after notification of such decision, file a written appeal with the Board. The written appeal shall be heard by the Board within forty-five (45) days from the date of filing. The Board shall make a final ruling on the appeal within sixty (60) days from the date of the filing of an appeal. Rule 08-11. Annual Publication of Enforcement Proceedings. The Water Utility shall annually publish, in the largest daily newspaper published in Kenosha, a list of industrial users which, during the previous twelve (12) months, were in significant noncompliance with applicable pretreatment standards and requirements. Significant noncompliance and/or criteria are listed in [Rule] 08-01. Rule 08-12. Grease Management. Rule 08-12(01). Purpose. The purpose of this rule is to establish uniform requirements for food service establishments discharging grease wastewater into the Water Utility wastewater collection system and to enable the Water Utility to comply with all applicable federal and state laws, including those, which apply to sanitary sewer overflows. Rule 08-12(02). Food Service Establishments. A. General. All food service establishments are required to have a grease trap or grease interceptor as per the requirements of the Wisconsin Administrative Code, SPS 382.34(5) as may be amended from time to time. B. New facilities. Upon the effective date of this rule, food service establishments which are newly proposed or constructed, or existing facilities which will be expanded or renovated, where such facility did not previously exist, shall be required to install, operate and maintain a grease interceptor or grease trap according to the requirements of the Wisconsin Administrative Code, SPS 382.34(5). C. Existing facilities. For the purposes of sizing and installation of grease interceptors, all food service establishments existing prior to the effective date of this rule shall be permitted to operate and maintain existing grease interceptors or grease traps provided same are in efficient operating condition. Upon the effective date of this rule, the Water Utility may require an existing food service establishment to install, operate and maintain a new grease interceptor or trap that complies with the requirements of this chapter or to modify or repair any noncompliant plumbing or existing interceptor or trap within ninety (90) days of written notification by the Water Utility when any one (1) or more of the following conditions exists: 1. The facility is found to be contributing oils and grease in quantities sufficient to cause line stoppages or necessitate increased maintenance on the wastewater collection system; 2. The facility has an undersized, irreparable or defective grease interceptor or trap; 3. The facility has a garbage grinder; 4. Remodeling of the food preparation or kitchen waste plumbing system is performed which requires a plumbing or building permit to be issued; 5. The existing facility is sold or undergoes a change of ownership. D. Plumbing connections. Grease interceptors or traps shall be located in the food service establishment's lateral sewer line after all fixtures that may introduce grease into the sewer system and the connection to the wastewater collection system. Such fixtures shall include but not be limited to, sinks, dishwashers, automatic hood wash units, floor drains in food preparation and storage areas, and any other fixture which is determined to be a potential source of grease. Garbage grinders installed within food service establishments shall be plumbed through the grease interceptor(s) and a solids interceptor shall separate the discharge before connecting to the grease trap. Solids interceptors and grease interceptors shall be sized and rated for the discharge of the garbage grinder. Wastewater from sanitary facilities and other similar fixtures shall not be introduced into the grease interceptor or trap under any circumstances. E. Grease interceptors. Grease interceptors shall be installed at all new food service establishments as specified by the Wisconsin Administrative Code, SPS 382.34(5). All food service establishments shall comply with the following guidelines: 1. Inspection, pumping, and maintenance. Each food service establishment shall be responsible for the costs of installing, inspecting, pumping, cleaning and maintaining its grease interceptor. Pumping services shall include the initial complete removal of all contents, including floating materials, wastewater and bottom sludge and solids from the interceptor. Grease interceptor cleaning shall include scraping excessive solids from the walls, floors, baffles and all pipe work. The return of gray water back into the grease interceptor from which the wastes were removed is allowable, provided that grease and solids are not returned to the interceptor. The grease hauler shall wait at least twenty (20) minutes to allow the interceptor waste to separate in the truck tank before attempting to re-introduce the gray water to the interceptor. It shall be the responsibility of each food service establishment to inspect its grease interceptor during the pumping procedure to ensure that the interceptor is properly cleaned out and that all fittings and fixtures inside the interceptor are in working condition and functioning properly. 2. Interceptor pumping frequency. Each food service establishment shall determine the frequency at which its grease interceptor(s) shall be pumped according to the following criteria: a. When the floatable grease layer exceeds six (6) inches in depth as measured by an approved dipping method; or b. When the settleable solids layer exceeds eight (8) inches in depth as measured by an approved dipping method; or c. When the total volume of settleable solids is more than three-quarters (¾) of the total clearance of the outlet pipe located at the bottom of the interceptor; or d. When the total volume of captured grease and solid material displaces more than twenty (20) percent of the capacity of the interceptor as calculated using an approved dipping method. 3. Repairs. Each food service establishment shall be responsible for the cost and scheduling of all repairs to its grease interceptor(s). Repairs required by the Water Utility shall be completed within ten (10) calendar days after written notice is received by the facility unless the Water Utility establishes a different compliance date. 4. Disposal. Wastes removed from each grease interceptor shall be disposed of at a facility permitted to receive such wastes. Neither grease nor solid materials removed from interceptors shall be returned to any grease interceptor, private sewer line or to any portion of the wastewater collection system. F. Interceptor additives prohibited. Any chemicals, enzymes, emulsifiers, live bacteria or other grease cutters or additives are prohibited. G. Alternative grease removal devices or technologies. Alternative devices and technologies such as automatic grease removal systems shall be subject to written approval by the Water Utility prior to installation. Approval of the device shall be based on demonstrated (proven) removal efficiencies and reliability of operation. The Water Utility may approve these types of devices depending on manufacturers' specifications on a case-by-case basis. The food service establishment may be required to furnish analytical data demonstrating that grease discharge concentrations to the wastewater collection system will not exceed the established limitation. Rule 08-12(03). Entry, Inspection, Sampling, and Reporting. A. Entry. All food service establishments shall allow Water Utility personnel, bearing proper credentials and identification, access to all parts of the premises during reasonable business hours, for the purpose of inspection, observation, and sampling in accordance with the provisions of this rule. Any user refusing the Water Utility entry to or upon the premises of the user for the purposes of inspection, sampling effluents or performing such other duties as required by this rule shall constitute a violation of the terms of this rule. The Water Utility may seek a warrant or use any other legally available procedures to discharge their duties. B. Inspection and sampling. The Water Utility may inspect the facilities of any food service establishment, to determine compliance with this rule. Grease interceptors shall be inspected as necessary to ensure compliance with specific grease interceptor requirements and to determine if proper cleaning and maintenance schedules are being performed. The Water Utility may collect effluent samples to determine compliance. The Water Utility shall re-inspect any user that received a deficiency notice after the original inspection. In the event that the user is compliant with all of the deficiencies, there shall be no charge for the re-inspection. In the event of continuing noncompliance, successive re-inspections will be scheduled and appropriate fees shall be charged to the user for the first and all successive re-inspections. Such fees may be charged to the appropriate account of the customer's sewer bill. C. Reporting. Owners of grease trap/interceptors shall obtain records from contractors used to remove grease waste showing the volume of grease waste shipped; the name and address of the destination; and the name and address of the contractor. Owners of grease trap/interceptors shall maintain these records for a minimum of five (5) years and make them available to the Water Utility for inspection and copying upon request. Rule 08-12(04). Enforcement and Damage Assessment. A. Enforcement response plan. Whenever the Water Utility determines that a grease interceptor is in need of pumping, repairs or other maintenance, or in the event that an additional grease interceptor is required, the Water Utility shall proceed as prescribed below: 1. If during inspection, the Water Utility determines that a violation exists, the Water Utility shall immediately notify the owner/manager of the food service establishment that a violation exists and must be addressed promptly. 2. The Water Utility may issue the food service establishment a notice of violation (NOV) stating the nature of the violation(s). Upon issuance of a NOV: The Water Utility shall perform a first re-inspection after a minimum of fifteen (15) calendar days after issuance of the NOV, to allow sufficient time for corrective action by the food service establishment to be completed. In the event that the food service establishment is compliant with all of the deficiencies, there shall be no charge for the re-inspection. If all of the deficiencies have not been corrected, a first re-inspection fee shall be charged to the food service establishment. A second re-inspection will be performed after a minimum of ten (10) additional calendar days have passed. In the event that the food service establishment is compliant with all of the deficiencies, there shall be no additional charge for the re-inspection. If deficiencies remain, a second re-inspection shall be charged to the food service establishment. Additional re-inspections and fees will be assessed until the food service establishment is compliant with all of the deficiencies. If necessary, additional enforcement actions may be necessary. Fees shall be established and, when necessary, modified by the Board. B. Assessment of damages. When the discharge from a food service establishment causes an obstruction, damage or any other impairment to the facilities or any expense of whatever character or nature to the Water Utility, the Water Utility may charge the expenses incurred to the discharger. The expenses include services to clear the obstruction, repair the damage to the Utility's facilities or to recover any other expenses for damage(s) of any kind or nature suffered by the Water Utility. The Water Utility shall file a claim with the food service establishment or person causing the damages for any and all expenses or damages suffered by the Water Utility. If the claim is ignored or denied, the Water Utility may charge the expense to the Water Utility sewer bill, or notify the city attorney to take such measures as shall be appropriate to recover any expense or damages suffered by the Water Utility. Rule 08-12(05). Permit Requirements. A. It is unlawful for any facility to discharge effluent from a grease interceptor without authorization from the Water Utility. Authorization shall be given in the form of a Grease Interceptor Permit. Application for a permit shall be made to the Water Utility. If the Water Utility determines that the proposed discharge does not conflict with the provisions of this Chapter, or any other federal, state or local requirement or regulation, and the permit fee is paid, a permit shall be issued allowing the facility to discharge into the sanitary sewer collection system. Each grease interceptor permit shall be issued for a time not longer than three (3) years from the date of the permit. The grease generator shall apply for permit re-issuance prior to the expiration of the grease generator's existing permit. Rule 08-12(06). Fees. The Board may establish and, from time to time, modify charges, surcharges, and fees for permit application, operation, enforcement, administration, and reimbursement of costs incurred. Rule 08-13. Amalgam Management at Dental Offices. A. This rule applies to any dental office that places or removes amalgam. If work in a dental office is limited to work that does not involve placing or removing amalgam, such as orthodontics, periodontics, maxillo-facial surgery, endodontics, or prosthodontics, then this rule does not apply. B. All dental offices shall implement best management practices for amalgam as established by the Wisconsin Dental Association. C. Within the shortest reasonable time, but no later than four (4) years from the effective date of this Chapter, every vacuum system where amalgam is used or removed shall include an amalgam separator that meets the criteria of the International Standards Organization for amalgam removal equipment (ISO 11143). Dental office shall install, operate and maintain the amalgam separator according to manufacturer's instructions. The amalgam separator shall have a design and capacity appropriate for the size and type of vacuum system. D. Within one (1) year of the adoption of this Chapter, each dental office shall submit a report that certifies the implementation of the management practices required by paragraph 08-13 B and identifies the contractors used to remove amalgam waste within the last twelve (12) months. E. Within two (2) years of the adoption of this Chapter, each dental office shall provide a schedule for the installation of the amalgam separator required by paragraph 08-13 C. F. Within three (3) years of the adoption of this Chapter, each dental office shall provide the following information: 1. The installation date, manufacturer and model name of the amalgam separator, if the installation of the separator is completed. 2. A brief explanation of the delay, anticipated installation schedule, proposed manufacturer and model name of the amalgam separator, if the separator has not yet been installed. G. If the dental office has provided a report according to paragraph 08-13.F., the dental office shall notify the Water Utility of the completion of the installation within five (5) days after completion. H. Dental offices shall obtain records for each shipment from contractors used to remove amalgam waste showing the volume or mass of amalgam waste shipped; the name and address of the destination; and the name and address of the contractor. Dental offices shall maintain these records for a minimum of five (5) years and make them available to the Water Utility for inspection and copying upon request. I. Dental offices shall allow the Water Utility to inspect vacuum system, amalgam separator, and amalgam waste storage areas upon request. Inspections shall occur during the normal operating schedule of the dental office. J. If the dental office is implementing the management practices required by paragraph 08-13.B. and is operating and maintaining the amalgam separator required by paragraph 08-13.C., then any numerical discharge limit for mercury established in any other section of this Chapter does not apply. Rule 08-14. Record Retention by Dischargers. Dischargers subject to this Section shall retain and preserve, for no less than three (3) years, any records, books, documents, memoranda, reports, correspondence, and any and all summaries thereof relating to monitoring, sampling and chemical analyses made in connection with its wastewater discharge. All records that pertain to matters that are the subject of administrative adjustment or any other enforcement or litigation activities brought by the Water Utility pursuant hereto shall be retained and preserved by the discharger until all enforcement activities and related review proceedings have concluded and all periods of limitation with respect to any and all appeals have expired. Records of any contractor or agent of the discharger must be retained by the discharger.

Ask a question about Kenosha law

Corpus searches the Kenosha sections it holds and shows the ones that match, with their citations. Free, no sign-in.