§ 103-170 — Oil heating

Municipal Code of the City of La Crosse, Wisconsin (Codified through Ordinance No. 5384, enacted August 13, 2026. (Supp. No. 43)) · La Crosse Municipal Code § 103-170

Corpus is an independent public-information project, not the official City of La Crosse website. Stable reference: corpuslaw.us/code/6597f2ce-767c-43d5-a94f-8758ca4cede8

Sec. 103-170. - Oil heating.

(a) Definitions. The following words, terms and phrases, when used in this section, shall have the meanings ascribed to them in this subsection, except where the context clearly indicates a different meaning: Fuel oil means any liquid used as fuel and having a flash point of not less than 110 degrees Fahrenheit. The Pensky-Martens closed cup tester shall be authoritative. The test shall be made in accordance with the methods of test adopted by the American Society for Testing Materials. Oil heating burner means any device designed and arranged for the purpose of burning fuel oil as defined in this subsection, and having a tank or container with a capacity of more than 20 gallons connected thereto. Oil heating equipment means all equipment connected to an oil heating burner and located within the building, internal and external supply or storage tanks and provisions for filling and venting, piping, wiring, and all accessories. (b) Approval of burner. No person shall install any oil heating burner unless the type of burner to be installed has been previously approved by the Fire Department - Division of Fire Prevention and Building Safety. The Fire Department - Division of Fire Prevention and Building Safety shall automatically approve any oil heating burner listed by the Underwriters Laboratory or any other nationally recognized inspection board or laboratory, but shall not approve any others until inspected and tested, including arrangement of parts, suitability of material, strength of parts, electrical control, thermostatic arrangement, reliability of automatic features, positiveness of ignition, and safeguards against flooding. If the Fire Department - Division of Fire Prevention and Building Safety does not feel it is competent to make the above test, it may require that the applicant submit a report from a recognized laboratory. The Fire Department - Division of Fire Prevention and Building Safety shall give the applicant reasons for any disapproval. (c) Oil heating equipment; permit for installation. No person shall install oil heating burners or oil heating equipment until the Fire Department - Division of Fire Prevention and Building Safety shall have issued a permit for the specific installation. Application for the permit shall be made in writing and accompanied by a sketch showing the layout of the proposed installation. The Fire Department - Division of Fire Prevention and Building Safety shall issue such permit or in writing notify the applicant of changes required before a permit will be issued, or the reasons why application is denied. Upon the required changes being made in the application or sketch, a permit shall be issued. No oil heating equipment of a different kind than that specified in the application, and no tanks of a different size, kind or quality shall be installed, nor shall the installation be made in any manner other than as described in such application or shown in the sketch submitted therewith. (d) Tanks. All tanks used with an oil heating burner shall conform to the following: (1) Material and construction. a. Tanks shall be constructed of galvanized steel, open hearth steel or wrought iron of a minimum gauge (U.S. Standard) depending on the capacity as given below: 1. 1 to 285 gallons: 16 gauge. 2. 286 to 56 gallons: 14 gauge. 3. 561 to 1,10 gallons: 12 gauge. 4. 1,101 to 4,00 gallons: 7 gauge. 5. 4,001 to 12,00 gallons: ¼ gauge. b. For tanks of 1,100 gallons or more, a tolerance of ten percent in capacity may be allowed. c. All joints shall be riveted and caulked, brazed, welded or made tight by some equally satisfactory process. Tanks shall be tight and sufficiently strong to bear without injury the most severe strains to which they may be subjected in practice. Shells shall be properly reinforced where connections are made. All connections shall be made through the top of the tank above the liquid level, except in tanks having a capacity of 275 gallons and less, where one connection may be made, not larger than one-inch iron pipe size, in the bottom of the tank. Unenclosed inside storage or gravity tanks of 275 gallons capacity and less may be provided with an additional one-inch opening in the bottom for an approved key stem gate valve to aid in cleaning. d. Underground tanks shall be thoroughly coated on the outside with tar asphaltum, red lead or asphaltum paint. e. Inside and above ground tanks and auxiliary tanks shall be coated with a good quality rust-resisting paint. (2) Location of tanks. a. Inside storage, gravity, and auxiliary pressure tank, not enclosed in masonry or concrete, shall be provided with securely attached, substantial, incombustible support, and be securely bolted to the basement floor or otherwise secured to avoid strains in the piping, and shall not be located within ten feet, measured horizontally, from any fire or source of flame. b. The aggregate capacity of exposed storage tanks installed in a cellar or basement and used in connection with one complete system shall not exceed 275 gallons capacity, except that two tanks of not more than 275 gallons capacity each may be installed in buildings occupied strictly for dwelling purposes, provided that they are so arranged that the contents of both tanks cannot be made available to the burner simultaneously. c. Storage tanks of over 275 gallons capacity shall be placed in an enclosure with inside dimensions six inches greater on all sides than the outside dimensions of the tanks. The walls of the enclosure shall be constructed of concrete not less than six inches in thickness or of eight inches of masonry. The walls shall be bonded to the floor and carried up to a height not less than one foot above the tank, and the space between the tank and the wall and the top of the enclosure shall be completely filled with sand or well-tamped earth. d. Storage tanks having a capacity greater than 550 gallons may be placed in the cellar or basement of any building below the level of the floor, provided that they are so placed that the top of the tank is not less than 12 inches below the level of the floor. e. Tanks located underground outside of any building shall be so placed that the top of the tank is not less than two feet below the surface of the ground, except that a tank may be buried under only 12 inches of earth if a cover of reinforced concrete at least three inches in thickness is provided which shall extend at least 12 inches on all sides of the tank. f. Where tanks are so located that the top of the tank is above the level of the suction inlet of the pump supplying oil to the burner or burner assembly, a siphon-breaking device consisting of an anti-siphon valve, a vacuum tank, Underwriters vacuum siphon breaker, siphon breaking pump set or an equivalent device to prevent siphoning shall be installed. g. Tanks of 275 gallons capacity and less may be used to supply oil to the burner by gravity, provided that there is a suitable automatic safeguard to prevent abnormal discharge of oil at the burner. When more than one storage tank is installed, such tanks shall be connected with the main feed pipe line leading to the burner through a manually operated three-way valve, so that not more than one tank can in any way discharge its contents at one time. h. Tanks of 60 gallons capacity and less may be used under pressure, provided that they shall be designed for six times the maximum pressure, which shall not exceed 50 pounds per square inch, and shall be proven tight at twice the maximum working pressure. Pressure tanks shall be equipped with a reliable gauge and an automatic relief valve piped to discharge by gravity to the storage tank. (3) Venting of tanks. a. Storage tanks shall have an open or automatically operated vent pipe of ample size to prevent abnormal pressures in cases of fire or when filling, and of not less than one-inch iron pipe size. b. The lower end of the vent pipe shall not extend through the top of the tank for a distance of more than one inch. c. The vent pipe shall extend from the tank to the outside air terminating at a point outside the building one foot above the level of the highest reservoir from which the tank may be filled and not less than two feet, measured vertically above or horizontally from any window or other building opening. Outer ends of the vent, unless automatically operated, shall be provided with a return bend or a weatherproof hood. (4) Filling pipes. All filling pipes shall be not less than two-inch iron pipe, shall terminate outside the building and when installed in the vicinity of any door or building opening shall be provided with a metal cover or cap which shall be closed tight when not in use. (5) Tank gauges. a. No oil tank used in connection with oil heating equipment shall be equipped with a glass gauge or any gauge the breaking of which will permit the oil to escape from the tank. b. Test wells shall not be located within the buildings. Test wells located outside of buildings shall be locked. (6) Scavenging line. A scavenging line, installed in connection with a tank located within a building, may be used and shall terminate outside the building. It shall be capped oil-tight when not in use. (7) Piping. a. Standard full weight wrought iron, steel or brass pipe with substantial fittings, or standard brass or copper tubing and fittings shall be used, and shall be carefully protected against mechanical injury. In all piping systems proper allowance shall be made for expansion and contraction, jarring and vibration. b. All threaded joints shall be tight and shall be made up with litharge and glycerin, shellac or suitable pipe compound. c. All piping shall be secured rigidly and protected from injury. (8) Pumps. All auxiliary pumps used for pumping oil from the storage tank to auxiliary tanks shall be of an approved type. They shall be rigidly mounted. (e) Other oil heating equipment. (1) Burner controls. a. All oil heating burners shall be equipped with a device, mechanical or electrical, which will automatically prevent an abnormal flow of oil. b. All oil heating burners subject to automatic ignition must be provided with a permanent automatic device, so designed that oil, upon being turned into the combustion chamber, will immediately become ignited or shut off. c. All oil heating burners used in connection with hot water, steam or warm air heating systems shall be equipped with an automatic device to reduce or extinguish the fire in event of undue pressure or overheating within the boiler or furnace. (2) Electrical installation. Electrical installations in connection with oil heating equipment shall comply with the Electrical Code of the City. (3) Chimney. No oil heating burner shall be installed in any boiler or heater unless said boiler or heater is connected with a chimney having sufficient draft at all times to insure the safe operation of the burner. (f) Ventilation. All boilers or furnace rooms shall be provided with adequate ventilation to insure continuous complete combustion. (g) Posting instructions. A printed copy of the rules and instructions of the manufacturer shall be conspicuously posted near every oil heating burner.

(Code 1980, § 18.02; Ord. No. 4911, § I(attch.), 1-14-2016)

Ask a question about La Crosse law

Corpus searches the La Crosse sections it holds and shows the ones that match, with their citations. Free, no sign-in.