For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 103-201 — Gas burner installations exceeding 400,000 BTUs

Municipal Code of the City of La Crosse, Wisconsin (Codified through Ordinance No. 5384, enacted August 13, 2026. (Supp. No. 43)) · La Crosse Municipal Code § 103-201

Corpus is an independent public-information project, not the official City of La Crosse website. Stable reference: corpuslaw.us/code/7fbeb974-4e09-4643-adbc-5bedf98810d4

Sec. 103-201. - Gas burner installations exceeding 400,000 BTUs.

(a) Definitions. The following words, terms and phrases, when used in this section, shall have the meanings ascribed to them in this subsection, except where the context clearly indicates a different meaning: Atmospheric burner means a device in which the air at atmospheric pressure is induced into the burner by a jet of gas under pressure not more than the house line pressure. Conversion burner means a gas burning device designed to supply gaseous fuel to and properly burn this fuel in the combustion space of equipment originally designed to burn another fuel. Duel fuel burner means a burner designed to burn gas or another fuel but not both simultaneously. Gas burner means a device for the final utilization of gas, or a mixture of gas and air in any steam, hot water boiler, furnaces, air heaters and devices and appliances for power, industrial, space heating and process uses in connection with a heating system or commercial and industrial applications, and shall include conversion burners, gas designed equipment, power burners, atmospheric burners, dual fuel burners and process and industrial equipment. Gas burner equipment means gas burners and all auxiliary and equipment accessories, including flue pipe control devices, electric wiring diagrams, piping diagrams, gas controls, safety controls, and accessories in connection with the equipment, and all piping supplying the equipment with gas, air, or mixtures thereof. Gas designed equipment means equipment designed as an integral unit for burning gas only as fuel. Gas pressure. Gas supply pressures shall be classified as follows: (1) Low pressure: Up to and including 14 inches W.C. (2) Medium pressure: From 14 inches W.C. to and including 25 p.s.i.g. (3) High pressure: Over 25 p.s.i.g. Power gas burner means one in which either gas or air or both are supplied at pressures exceeding, for gas, the normal line pressure at the burner, and for air, atmospheric pressure; the added pressure being applied at the burner. Process and industrial equipment means all gas burning equipment burning gas or a mixture of gas and air for industrial and process applications. (b) Compliance. (1) The construction, arrangement, manner of installation, alteration and repair of all gas burners for steam and hot water boilers, furnaces, industrial, power and process uses that exceed 400,000 BTU per hour shall conform to the following: a. Before approval for installation is granted for initial installation, plans and specifications and/or official literature and data, including piping arrangements, type and model of controls, capacities of equipment, and wiring diagram shall be submitted to the Fire Department - Division of Fire Prevention and Building Safety for preliminary approval. b. Upon receiving preliminary approval, the installation shall then be made accordingly, and final approval shall not be granted until the equipment has been tested in the presence of an inspector of the Department of Building and Inspections. Such tests shall consist of Orsat testing, within acceptable limits where applicable, pressure regulation, stack temperature, control operation, pilot turn down, flame lockout and such other tests as may be deemed necessary by the Fire Department - Division of Fire Prevention and Building Safety. (2) General regulations. a. All burners for space heating applications shall be accompanied by complete and comprehensive operating instructions and wiring diagrams, which shall be mounted on the equipment, or securely mounted adjacent to the equipment. b. Where burners are equipped with secondary air shutters or louvers, they must be designed or counter-balanced so as to drop to a wide open position in the event of failure or breakage of connecting linkage. They shall also be of sufficient area to supply adequate air for complete combustion under specified draft conditions and at maximum rate of firing. c. The burner or burners shall be located according to the manufacturer's instructions and shall be so secured that they will not slide, twist or drop out of position. d. The burner or burners shall be so installed as to be readily accessible for cleaning and inspection. e. The burner or burners shall be so installed that no part of flame shall impinge on heating surface so as to cause incomplete combustion. f. On all installations where the combustion air pressure can exceed the house line pressure, an approved check valve or other approved device shall be installed in the gas supply line to prevent air from backing into the gas line. g. Under no condition shall the equipment be fired at a capacity greater or less than that shown in the official data supplied by the manufacturer, or at greater or less gas pressure than the maximum or minimum pressures, as listed by the manufacturer or as approved by the Fire Department - Division of Fire Prevention and Building Safety. h. All equipment is to be installed in the basic manner in which the original approval was obtained, and wiring and piping diagrams shall accompany each permit application when the input is 1,000,000 BTU per hour or more and when different from the original approval or requested by the Fire Department - Division of Fire Prevention and Building Safety. (3) Piping. a. All gas piping under this section shall be wrought iron or black steel pipe where applicable with malleable or steel fittings, and shall be designed so that the pressure drop through the piping does not exceed that which will supply the proper pressure for the particular application, and shall be carefully tested for leaks. Adequate drips shall be installed at any point at which liquid condensate could collect, and such drips shall be readily accessible for cleaning. Gas piping shall not be supported from other pipes, and shall be securely hung so that proper grades will be maintained. b. Main shut-off cocks. An approved type of main shut-off cock shall be installed in a readily accessible location for the convenient operation of the burner and ahead of all other gas controls. When this cock is two inches in size or larger, or the gas pressure exceeds 14 W.C. pressure, it shall be of the lubricated type, and in all cases shall have a permanently attached handle, which shall clearly indicate the "on" and "off" position. c. Firing cocks. A firing cock of a suitable type may be installed downstream of all controls that start and stop the flow of gas to the firing equipment if desired. d. All pilot lines shall be equipped with an approved shut-off cock. (4) Combustion gas controls. a. For a burner or a combination of burners not exceeding 500,000 BTU input per hour, a combustion control of the on and off type may be used. This control may be of either the quick opening or slow opening type. b. For a burner or a combination of burners not exceeding 5,000,000 BTU input per hour, approved on and off types of controls may be used, provided a slow opening automatic gas valve is used. This valve shall have a maximum closing time of five seconds. In addition to the slow opening valve, an approved automatic valve of the position closing type shall be installed up stream of the slow opening type of valve. The positive closing type valve shall have a pressure rating of not less than the maximum street pressure when the inlet pressure is not regulated by the utility and not less than five p.s.i. when the inlet pressure is regulated by the utility, at a pressure not exceeding five p.s.i. c. For burners or a combination of burners with an input exceeding 5,000,000 BTU per hour, an approved modulating, or high-low type of gas control must be used in addition to the slow opening and positive gas valves described in subsection (b)(5)b of this section, or an approved combination modulating and slow opening valve. This modulating or high-low control shall be of a type that controls the firing rate of the equipment throughout its entire range, and so adjusted that the minimum and maximum firing rate stays within the limit as specified for the equipment by the manufacturer, and within the limits of the particular application to which it is applied. d. Modulating controls may use steam, air hydraulic or electricity as an actuating medium, and shall be so arranged that the gas burning equipment starts and stops in the minimum firing position on installations exceeding 5,000,000 BTU per hour. e. Modulating controls that are inter-connected by mechanical linkage to inlet air louvres of natural draft burners, shall have this linkage so arranged that the louvres will go to the open position in the event of failure of the linkage, provided such failure could change the fuel-air ratio. f. On equipment with approved programming controls, the positive closing gas valve may be either the automatic or the manual reset type. On equipment with constantly proved pilot, and on which the positive closing valve and flame failure control relay does not program with the starting and stopping of the main flame, the valve shall be of the approved manual reset type. On equipment with an input of less than 5,000,000 BTU per hour, automatic types of positive closing may be used on either type of pilot control, provided that they do not require the closing of a circuit or relay and are of the "normally closed" type of valve. (5) Gas pressure regulators. a. Approved types of gas regulators shall be used on all gas burner equipment. These regulators shall maintain a stable gas pressure to the equipment, within the range of pressure set up by the manufacture of the gas burning equipment. b. Low pressure. An approved gas pressure regulator shall be installed. c. Medium pressure. An approved pressure regulator shall be installed upstream of all other controls when the inlet pressure is not regulated by the utility and this regulator shall be rated at not less than the maximum street pressure. Where the inlet pressure is regulated by the utility at a pressure not exceeding five p.s.i. and approved regulator shall be installed. This regulator shall be rated at not less than five p.s.i. and may be either up or down stream of other operating controls. d. High pressure. Not less than two gas pressure regulators shall be installed downstream of the meter, one of these to be normally at the meter location and pressure reduction shall be accomplished in not less than two stages. Both the first and second regulators shall be designed for, and capable of handling the maximum street pressure available. If a third stage of regulation is desired, this regulator shall be rated for not less than the outlet pressure of the first stage regulator unless installed downstream of the operating controls. e. A limiting device shall be installed on the downstream side of the final stage of pressure regulating, on medium and high pressure. This limiting device shall be so arranged that it will close the main gas control valves in the event the gas pressure exceeds the proper regulated pressure. This limiting device shall be so arranged that it will require manual re-cycling or re-setting before the equipment can be put back in operation. (6) Operating and limiting controls. a. Steam boilers shall be equipped with not less than one operating control, and one high limit control, and low-water cut-off. b. Hot water boilers shall be equipped with not less than one operating and one high limit control, activated by boiler water temperature. Operating controls actuated by water temperature shall be of immersion type, mounted directly into the boiler water; the high limit control may be of the surface type, mounted on the rise or risers adjacent to the boiler, ahead of all flow or other controls. c. Warm air furnaces shall be equipped with not less than one operating and one high limit control. These controls shall be so located that failure of fans or air circulation through the unit will not appreciably affect their operation, or such fans shall be equipped with air switches to prevent operation of the equipment in the event of fan failure. d. Thermostats, where directly operating the gas burning equipment, may be considered operating controls. e. When forced or induced draft is used, an approved air switch shall be installed to prevent operation of the equipment at any time such draft is not definitely established and maintained at predetermined adequate setting. f. Electrically operated safety device shall not rely on closing a circuit or relay to close the main gas valve or valves. g. Primary air fans shall be equipped with an approved positive method of preventing the burner from starting or remaining in operation in the event of failure of the primary air source. (7) Plain pilot. a. Each burner shall be equipped with a plain gas pilot, or gas pilots in addition to the safety pilot to insure smooth lighting of the burners so that there will be no roll back or heavy detonations during lighting off period, except that where the burner unit is of such size that safety pilot will light burner smoothly, the plain pilot may be omitted. The pilot flame shall effectively ignite the gas at the burner and shall be so designed as to be adequately protected from drafts where required. Pilot flames shall not become extinguished by the main burners when starting or stopping them in a normal manner. Luminous flame pilots shall not show carbon deposit during the period of tests when adjusted according to the manufacturer's instructions. b. Where vertical or upshot type of burner consisting of a multiplicity of heads is used, a minimum of one plain gas pilot for each eight heads must be used. In arriving at the number of pilots, the safety pilot will be counted as one plain gas pilot above eight heads; below eight heads there must be at least one plain gas pilot and a safety pilot unless the Fire Department - Division of Fire Prevention and Building Safety approves a lesser number. (8) Safety pilots and controls. a. Where the total input to any gas burning device exceeds 400,000 BTU all burners shall be equipped with approved flame rectifier, flame conductivity or scanner cell types of safety controls. Heat sensitive types of pilots will not be permitted. b. Safety pilots shall be so designed that upon insertion of pilot after removal for repairs or cleaning, pilot will be in the same position relative to main burner as when originally installed. The pilot flame shall be in such a position that in the event of a drop in gas pressure, the contact between the pilot flame and flame rod or scanner shall be broken before the point where the pilot light will fail to reliably ignite the main burner. c. The control system used in conjunction with the electronic safety pilot shall be of a type to lock out the main flame in approximately five seconds or less, and shall require a manual re-set operation before flame can be re-established. All safety pilots shall be equipped with positive closing automatic gas valves, and shall close in the event of an indicated flame failure. d. Forced or induced draft equipment and natural draft type burners with supplementary air fans with modulating or closing air shutters with an input in excess of 1,000,000 BTU per hour shall be so arranged that a prepurge period of approximately 30 seconds is obtained. This prepurge shall occur before establishing ignition on intermittent or interrupted pilots, and before establishing main flame or continuously proved pilots. e. Where a switch is installed in the low-water cut-off circuit to keep the circuit to the safety shut-off valve closed when blowing down water column, the switch must be of the push button type, so that when operator releases button, the control circuit to safety shut-off valve will be normal. f. All pilot burners shall be supported in such a manner that their position relative to the main burner or burners will remain fixed. g. Pilot lines shall be connected to vertical supply lines when possible. When horizontal line is used, connection must be made on top or side. Connection must be ahead of all controls, (except pressure regulator on medium and high pressure) and main shut-off valve, and shall be provided with separate shut-off cock. Where gas pressure is greater than that for which pilots are designed, a pressure regulator (pilot regulator) must be installed on the downstream side of pilot line shut-off cock. h. Safety shut-off valves shall be tested to assure gas tightness of the seat when in a closed position; the valve assembly shall be gastight in all positions. Packing glands shall be designed so that the valve will not be made inoperative by excessive tightening of the packing nut. (9) Venting of controls. Pressure regulators, slow opening gas valves and other gas equipment requiring venting shall be vented to a safe point outside the building, or to a point in the breeching or stack, where the volume of flow of air is such that a combustible mixture cannot be obtained. (10) Draft controls. a. Approved draft controls are to be used on all equipment, except when forced and induced draft is used in conjunction with controls that modulate the forced or induced draft in the direct ratio with the fuel modulation, and shall be used with forced or induced draft modulating systems when they are attached to a stack which may disturb fuel air ratio due to its draft intensity to the equipment. b. Barometric draft controls. These draft controls are to be of the "gas" type control, free to swing both ways. Barometric type draft controls shall have a cross sectional area equal to approximately 75 percent of the cross sectional area of the breaching from equipment which they are regulating. c. Mechanical draft controls. This type of control may use hydraulic pressure, steam, air, or electricity as an actuating medium, and shall be so arranged that they will program to the open position before ignition is established on interrupted or intermittent piloted equipment, and before main flame is established on constantly proved pilot equipment, and shall be equipped with a positive means of delaying the equipment before the open position is obtained. (11) Dual fuel equipment. a. All dual fuel equipment, using gas as one of the fuels, must comply with the requirements of this section, in controlling the gas equipment, and shall be so arranged that no adjustments are changed or required when changing fuels. Dual fuel equipment shall be equipped with an on-off-on type of transfer switch that will not pass through the center off position without stopping in the off position. b. When atmospheric inshot gas burners are used for over stoker dual fuel operation, two automatic draft sensing controls shall be installed to insure a preset draft for each fuel. These two automatic draft sensing controls shall be electrically connected with the control systems so that each draft sensing control will be electrically interlocked with its respective fuel. c. Inshot type gas burners installed for dual fuel operation shall be equipped with a sliding protective refractory slab that can be easily positioned in front of the gas burner firing nozzles when the other fuel is being used. The sliding protective refractory slab shall be interlocked electrically with the control system so as to prohibit accidental operation of the gas burner when the protective slab is positioned for other fuel operation. Note: The protective slab may be omitted when using power gas burners installed for dual fuel operation provided continuous fan operation is maintained while the gas burner is on standby. (12) Inspection and tests. All installations shall be carefully tested for the proper operation of all controls and electrical circuits. Upon completion of fire testing and adjusting, a complete test report shall be filed with the Fire Department - Division of Fire Prevention and Building Safety in accordance with forms supplied by the Fire Department - Division of Fire Prevention and Building Safety. Piping shall be carefully tested for leaks. (13) Industrial applications. On certain industrial and process applications, where certain parts of these regulations cannot be met as required, individual approval must be obtained from the Fire Department - Division of Fire Prevention and Building Safety, before a permit will be issued, or installation can be made. (14) Air intakes. Gas burning equipment in buildings where adequate air for combustion is not assured, shall have fresh air intakes of the permanently open type, or with closeable dampers. Air intakes with closeable or automatic type dampers that program with the equipment shall be equipped with a positive lockout device to prevent operation of the equipment unless the damper is open to a predetermined position.

(Code 1980, § 18.04(L); Ord. No. 4911, § I(attch.), 1-14-2016)

Ask a question about La Crosse law

Corpus searches the La Crosse sections it holds and shows the ones that match, with their citations. Free, no sign-in.