§ 46-112 — Pretreatment facilities
Municipal Code of the City of La Crosse, Wisconsin (Codified through Ordinance No. 5384, enacted August 13, 2026. (Supp. No. 43)) · La Crosse Municipal Code § 46-112
Corpus is an independent public-information project, not the official City of La Crosse website. Stable reference: corpuslaw.us/code/36f4c596-cacd-4cfe-b8e1-e821652b7007
Sec. 46-112. - Pretreatment facilities.
(a) Submission of pretreatment plans. Where pretreatment or equalization of wastewater flows prior to discharge into any part of the wastewater treatment system is required, complete plans, specifications, and other pertinent data or information relating to such pretreatment or flow-control facilities shall be submitted to the Board and the Wisconsin Department of Natural Resources (WDNR) for review and approval at least 60 days prior to initiation of construction. Such approval shall not exempt the applicant from compliance with any applicable code, ordinance, rule, regulation, or order from any governmental authority. Any subsequent alterations or additions to such pretreatment or flow control facilities shall not be made without due notice to and prior approval of the Board. (b) Protection from accidental discharge. Each nondomestic user shall provide protection from accidental discharge of prohibited materials or other wastes regulated by this division. Facilities to prevent accidental discharge of prohibited materials shall be provided and maintained at the owner's or operator's expense. Detailed plans showing facilities and operating procedures to provide this protection shall be submitted to the Board for review at least 60 days prior to the construction of the facility. Review and approval of such plans shall not relieve said user from the responsibility to modify its facility as necessary to meet the requirements of this division. (c) Reporting of accidental discharge. If, for any reason, a facility does not comply with or will be unable to comply with any prohibition or limitation in this division, or has experienced or is experiencing operational upsets, including but not limited to slug discharges, the user shall immediately notify the Director of Public Works or the Wastewater Utility Superintendent so that corrective action may be taken to protect the wastewater treatment system. In addition, a written report addressed to the Board shall be filed within five days of the occurrence of the noncomplying discharge. The written report shall detail the date, time, and cause of the accidental discharge, the quantity and characteristics of the discharge, and corrective action taken to prevent future accidental discharges. (d) Bypass. (1) An industrial user may allow any bypass to occur which does not cause pretreatment standards or requirements to be violated, but only if it is also for essential maintenance to assure efficient operation. (2) If an industrial user knows in advance of the need for a bypass, it shall submit prior notice to the Control Authority, if possible, at least ten days before the date of the bypass. (3) Bypass is prohibited, and the Control Authority may take enforcement action against an industrial user for a bypass unless: a. The bypass was unavoidable to prevent loss of life, personal injury, or severe property damage; or b. There were no feasible alternatives to the bypass. (e) Grease, oil, and/or sand interceptors. Grease, oil, and sand interceptors shall be provided when, in the opinion of the Board, they are necessary for the proper handling of liquid wastes containing floatable oil or grease in an excessive amount, or sand or other harmful ingredients, except that such interceptors shall not be required for private living quarters or dwelling units. All interceptors shall be of a type and capacity approved by the Board, and shall be located so as to be readily accessible for cleaning and inspection. The user shall clean and maintain these interceptors as required to maintain efficient removal of grease, oil, and/or sand. In maintaining these interceptors, the owner(s) shall be responsible for the proper removal and disposal by appropriate means of the captured material, and shall maintain records, which are subject to review by the Board, of the dates and means of disposal, including manifests, if used. (f) Dilution. No user shall increase the use of potable or process wastewater in any way, nor mix separate waste streams for the purpose of diluting a discharge as a partial or complete substitute for adequate treatment to achieve compliance with the standards set forth in this division. (g) Admission to property. Whenever it shall be necessary for the purpose of these rules and regulations, the Board or its duly appointed representatives, upon presentation of credentials, may enter upon any user's property or premises at any time, either scheduled or unscheduled, for the purpose of: (1) Inspection of premises. (2) Copying any records required to be kept under the provisions of this division. (3) Inspecting any monitoring equipment or method, any pretreatment facilities, or facilities creating process discharges. (4) Sampling any discharge of wastewater to the wastewater treatment system.
(Code 1980, § 6.11(F))
Ask a question about La Crosse law
Corpus searches the La Crosse sections it holds and shows the ones that match, with their citations. Free, no sign-in.