For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 30.02 — DEFINITIONS

Madison General Ordinances (Rev. 28, Update 3: codified through ORD-26-00040, published August 3, 2026) · Madison General Ordinances § 30.02

Corpus is an independent public-information project, not the official City of Madison website. Stable reference: corpuslaw.us/code/6e3ebf12-a321-4a32-a0f6-9d2526bcecf5

30.02 - DEFINITIONS.

Active Solar Collector. An active solar collector is a device that transforms light energy from solar radiation into heat energy. (This definition does not include passive solar devices or installations.) (Cr. by Ord. 8348, 5-25-84) Active Solar Thermal System. An active solar thermal system is an auxiliary heating system using solar collectors to augment the building's primary heat source for space or water heating. (This definition does not include passive solar greenhouses.) (Cr. by Ord. 8348, 5-25-84) Air Conditioner, Unitary. A unitary air conditioner consists of one (1) or more factory-made assemblies which normally include an evaporator, or cooling coil, a compressor and condenser combination, and may include a heater function as well; where such equipment is provided in more than one (1) assembly, the separated assemblies are described to be used together. Air Conditioning. The simultaneous control of the temperature, humidity, air motion, and air distribution within an enclosure, where human comfort and health are involved. A reasonable air purity with regard to dusts, bacteria, and odors is also included. Air Infiltration. The leakage of air into a house through cracks and crevices and through doors, windows and other openings, caused by wind pressure and/or temperature difference. Boiler. A closed vessel in which a liquid is heated or vaporized and built in conformance with the American Society of Mechanical Engineers Boiler and Pressure Vessel Code. (Am. by ORD-21-00016, 3-8-21) Boiler, High Pressure. A boiler furnishing steam at pressure in excess of fifteen (15) pounds per square inch gauge. Boiler Hot Water and Low Pressure Steam. A boiler furnishing hot water at pressure not more than thirty (30) pounds per square inch gauge or steam at pressures not more than fifteen (15) pounds per square inch gauge. Building. Any structure built for the support, shelter or enclosure of persons, animals, chattels, or movable property of any kind, and which is permanently affixed to the land. Central Heating Equipment. Equipment used to generate heat which is distributed by means of pipes or ducts to furnish heat to areas other than those in which the equipment is located. Coefficient of Heat Transmission (Overall) -U-. The amount of heat transmitted from air to air in one (1) hour per square foot of the wall, floor, roof, or ceiling for a difference in temperature of one (1) degree Fahrenheit between the air on the inside and outside of the wall, floor, roof or ceiling. Conduction (Thermal). The transmission of heat through and by means of matter. Convection. The transmission of heat by circulation (either natural or forced) of a liquid or gas such as air. If natural, it is caused by the difference in weight of hotter and colder fluid. Convector. A concealed radiator. An enclosed heating unit located (with enclosure) either within, adjacent to, or exterior to the room or space to be heated, but transferring heat to the room or space mainly by the process of convection. A shielded heating unit is also termed a convector. If the heating unit is located exterior to the room or space to be heated, the heat is transferred through one (1) or more ducts or pipes. Conversion Oil Burner. A burner for field installation in heating appliances such as boilers, furnaces, etc. It may be furnished with or without a primary safety control. Under special circumstances it may be installed for firing ovens, water heaters, ranges, special furnaces, and the like. A burner of this type may be a pressure atomizing gun type, a horizontal or vertical rotary type or a mechanical or natural draft vaporizing type. Converter. A piece of equipment for heating water with steam without mixing the two. It may be used for supplying hot water for domestic purposes or for a hot water heating system. Draft Regulator. A device which functions to maintain a desired draft in the fired appliance by automatically reducing the chimney draft to the desired value. Furnace Room. A room in which heat generating equipment is installed. One-Pipe System (Hot Water). A hot water heating system in which one (1) pipe serves both as a supply main and also as a return main. The heating units have separate supply and return pipes but both are connected to the same main. One-Pipe System (Steam). A steam heating system consisting of a main circuit in which the steam can condensate flow in the same pipe. There is but one connection to each heating unit which must serve as both the supply and the return. Panel Heating Systems. A heating system in which heat is transmitted by both radiation and convection from panel surfaces to both air and surrounding surfaces. Radiant Heating. A heating system in which the heating is by radiation only. Sometimes applied to panel heating system. Radiation. The transmission of heat in a straight line through space. Radiator. A heating unit located within the room to be heated and exposed to view. A radiator transfers heat by radiation to objects "it can see" and by conduction to the surrounding air which in turn is circulated by natural convection. Register. A grille with a built-in damper or shutter. Square Foot of Heating Surface. Equivalent direct radiation (EDR). By definition that amount of heating surface which will give off two hundred forty (240) BTU per hour when filled with a heating medium at two hundred fifteen (215) degrees Fahrenheit and surrounded by air at seventy (70) degrees Fahrenheit. The equivalent square foot of heating surface may have no direct relation to the actual surface area. Steam Heating System. A heating system in which the heating units give up their heat to the room by condensating the steam to them by a boiler or other source. Steam Trap. A device for allowing the passage of condensate and air but preventing the passage of steam. See Thermostatic Trap. Thermostat. An instrument which responds to changes in temperature and which directly or indirectly controls the room temperature. Thermostatic Trap. A steam trap which opens by a drop in temperature such as when cold condensate or air reaches it and closes it when steam reaches it. The temperature sensitive element is usually a sealed bellows or series of diaphragm chambers containing a small quantity of volatile liquid. Two-Pipe System (Steam or Water). A heating system in which one (1) pipe is used for the supply main and another for the return main. The essential feature of a two-pipe hot water system is that each heating unit receives a direct supply of the heating medium which cannot have served a preceding heating unit. Unit Heater. A direct-heating, factory-made, encased assembly including a heating element, fan and motor, and directional outlet. Vacuum Heating System (Steam). A one (1) or two (2) pipe system equipped with the necessary accessory apparatus to permit the pressure in the system to go below atmospheric. Vapor Heating System (Steam). A two-pipe heating system which operates under pressure at or near atmospheric and which returns the condensation to the boiler or receiver by gravity. Ventilation. Air circulated through a room for ventilating purposes. It may be mechanically circulated with a blower system or it may be natural circulation through an open window, etc. Vent Valve (Steam). A device for permitting air to be forced out of a heating unit or pipe and which closes against water and steam. Vent Valve (Water). A device permitting air to be pushed out of a pipe of heating unit but which closes against water. Wet Return (Steam). That part of a return main of a steam heating system which is completely filled with water of condensation.

Ask a question about Madison law

Corpus searches the Madison sections it holds and shows the ones that match, with their citations. Free, no sign-in.