Sec. 18-173. - Stairways, landings, platforms and roof decks.

(a) Every exit stairway shall be not less than three feet in width, and not more than four inches on one side may be used for handrails. Every platform shall be at least as wide as the stairway, measured at right angles to the direction of travel. Whenever a door opens onto a stairway, a platform shall be provided extending at least the full width of the door in the direction of travel. (b) If stairways are provided in addition to those required by this article, such additional stairways need not conform to the width requirements of this article. (c) All stairway landings, platforms, roof decks, or similar elevations or depressions more than two feet above or below adjacent grade or floor level shall have a guardrail on the open sides thereof, at least 36 inches in height, with intermediate rails, balusters, or other construction such that a sphere with a diameter of six inches cannot pass through any opening. (d) Handrails. All stairways and steps of more than three risers shall have at least one handrail. The handrail along stairways shall measure between 30 and 36 inches in height, measured above the stair nosing. Handrails must be installed on all open sides, if any, and this shall meet the minimum requirements. (e) Risers and treads. All stairways and steps shall have a uniform rise of not more than eight inches, and a minimum tread width of nine inches. Risers shall be measured from tread to tread, and treads shall be measured from rise to rise. There shall be no more than 18 risers in any one run. (f) The continuous clear head room measured perpendicularly from the nosing shall be not less than six feet eight inches, except that for basement stairways such head room may be six feet four inches. (g) Winders may be used provided that such winders are designed so the tread width 18 inches from the converging end will not be less than nine inches.

(Code 1973, § 30.15.080; Ord. No. 6-92, pt. 15, 3-3-92; Ord. No. 4-95, pts. 1, 2, 3-21-95)

Ask a question about Racine law

Corpus searches the Racine sections it holds and shows the ones that match, with their citations. Free, no sign-in.