Sec. 18-178. - Insulation.
(a) Outside walls and sill boxes shall have a minimum of 3½ inches in thickness of insulation with a minimum rating of R-11. Ceilings shall have a minimum of six inches in thickness of insulation with a minimum rating of R-19. (b) All windows must be double glazed, insulating glass, or have storm windows, and the frames thereof shall be caulked. All outside doors shall have storm doors, and the frames thereof shall be caulked. All openable windows and outside doors shall be weatherstripped. (c) Crawl spaces vented to the outside shall have a minimum of six inches of insulation with a minimum rating of R-19 on floors above. (d) Weather protection. When interior plastering work is in progress, adequate ventilation shall be provided, and in freezing weather the enclosure shall be heated. Plaster shall not be applied to surfaces that contain frost.
(Code 1973, § 30.15.130)