Sec. 18-271. - Wood roof decking.
The following specifications shall be observed in the construction of wood roof decking: (1) Planks shall be tongue and groove or splined; minimum thickness shall be two inches, maximum width shall be eight inches. (2) Planks shall be continuous over at least two spans. All joints shall be cut parallel to and over center of roof beams with not more than two adjacent planks breaking joints over the same support except at ends and at openings. (3) Maximum span of two-inch plank shall not exceed the following: a. Planks continuous over two supports, eight feet. b. Planks over single span, six feet. c. Other spans or thicknesses may be used when calculated according to standard engineering practices. Deflection shall be limited to 1/240 of span. (4) Tongue and groove planks having end matched end joints may be used to break joints between roof beams provided: a. Each plank bears upon at least two supports. b. End joints between supports shall not occur in adjacent planks. (5) The roof deck shall be blind and face nailed to roof beams in accordance with the nailing schedule in Table No. 4, section 18-442. (6) When the roof deck is also the finished ceiling surface, an approved vapor barrier shall be installed between deck and roof insulation.
(Code 1973, § 30.31.010)
Ask a question about Racine law
Corpus searches the Racine sections it holds and shows the ones that match, with their citations. Free, no sign-in.