§ 18-272 — Fiberboard roof deck
Municipal Code of the City of Racine, Wisconsin (Codified through Ordinance No. 0082-26, adopted March 3, 2026. (Supp. No. 108)) · Racine Municipal Code § 18-272
Corpus is an independent public-information project, not the official City of Racine website. Stable reference: corpuslaw.us/code/66ba31d7-f00a-4166-9551-3f9d5b43bf30
Sec. 18-272. - Fiberboard roof deck.
In fiberboard roof decks: (1) Thickness and joist spacing shall comply with manufacturer's specifications and be designed in accordance with roof loads designated in this article. (2) End joints shall be staggered and shall occur over supports at least three inches in width. Side joints shall be supported at eaves, ridge and openings. Nails shall penetrate supporting members at least 1½ inches and shall be spaced a maximum of five inches apart.
(Code 1973, § 30.31.020)
Ask a question about Racine law