Sec. 18-423. - Mounting.
(a) Domestic type incinerators, except as provided in this section, shall be mounted on floors of fire-resistive construction with noncombustible flooring or surface finish and with no combustible material against the underside thereof. Such construction shall extend not less than 12 inches beyond the incinerator base on all sides, except that at the front or side where ashes are removed, it shall extend not less than 18 inches beyond the incinerator. (b) Domestic type incinerators that are specifically approved for installation on a combustible floor may be mounted in accordance with the conditions of such approval.
(Code 1973, § 30.42.030)