For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 18-426 — Flue pipes

Municipal Code of the City of Racine, Wisconsin (Codified through Ordinance No. 0082-26, adopted March 3, 2026. (Supp. No. 108)) · Racine Municipal Code § 18-426

Corpus is an independent public-information project, not the official City of Racine website. Stable reference: corpuslaw.us/code/3cd85d86-f13b-4fa4-a877-df63999b4bf3

Sec. 18-426. - Flue pipes.

(a) Domestic type incinerator flue pipes, except as provided in this section, shall be installed to provide clearance of not less than 18 inches to woodwork or other combustible material. (b) Domestic type incinerator flue pipes may be installed in rooms, but not in confined spaces such as alcoves with reduced clearances to woodwork or other combustible material, provided the combustible material is protected with an approved protective material. (c) Domestic type incinerator flue pipes shall not pass through any combustible wall or partition unless protected at the point of passage in accordance with subsection 18-405, and sections 18-406 and 18-407.

(Code 1973, § 30.42.060)

Ask a question about Racine law

Corpus searches the Racine sections it holds and shows the ones that match, with their citations. Free, no sign-in.