For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 13.17.050 — Definitions

Municipal Code of the City of Casper, Wyoming (Codified through Ordinance No. 06-26, adopted July 7, 2026. (Supp. No. 97)) · Casper Municipal Code § 13.17.050

Corpus is an independent public-information project, not the official City of Casper website. Stable reference: corpuslaw.us/code/406086f5-fa20-4c14-9557-90cc342c669d

13.17.050 - Definitions.

The following definitions shall apply to this chapter: A. "Administrator" means the city manager or his appointed designee. B. "Approved" means accepted by the administrator as meeting an applicable specification stated or cited in this chapter, or as suitable for the proposed use. C. "Approved backflow prevention device" means a device that has been certified by the American Society of Sanitary Engineers (ASSE), the International Association of Plumbing/Mechanical Officials (IAPMO), or the Foundation for Cross-Connection Control and Hydraulic Research, University of Southern California (USC-FCCCHR) in accordance with state department of environmental quality water quality chapter 12 rules and regulations. D. "Auxiliary water supply" means any water supply on or available to the consumer's premises other than the supplier's approved public potable water supply. Auxiliary water may include water from another supplier's public potable water supply or any natural source(s) such as a well, spring, river, stream, etc., or "used waters" or "industrial fluids." These waters may be contaminated or polluted, or they may be objectionable and constitute an unacceptable water source of which the water supplier does not have sanitary control. E. "Backflow" means the flow of water or other liquids, mixtures or substances, under positive or reduced pressure into the distribution pipes of the potable water supply from any source other than its intended source. F. "Backflow assembly tester" means an individual certified to perform backflow/back siphonage device testing by the American Society of Sanitary Engineers (ASSE), or the American Backflow Prevention Association (ABPA). In addition, individuals licensed by a state certification program in the state or other states approved by the state department of environmental quality shall be considered acceptable for backflow/back-siphonage device testing, provided the individual holds a current license from the respective state certification program. G. "Backflow preventer" means a device or means designed to prevent backflow or back-siphonage events from contaminating the potable water supply system and most commonly categorized as air gap, reduced pressure principle device, double check value assembly, double detector check valve assembly, pressure vacuum breaker, atmospheric vacuum breaker, and double check with intermediate atmospheric vent. 1. "Air gap" means a physical separation sufficient to prevent backflow between the free-flowing discharge end of the potable water system and any other system. "Air gap" is physically defined as a distance equal to twice the diameter of the supply side pipe diameter but never less than one-inch. 2. "Atmospheric vacuum breaker" means a device which prevents back-siphonage by creating an atmospheric vent when there is either a negative pressure or sub-atmospheric pressure in the water system. These devices are not suitable for protection against back-pressure events. These devices shall be installed vertically, must not have shut-off downstream, and must be installed at least six inches higher than the final outlet. 3. "Double check valve assembly" means an assembly of two independently operating spring loaded check valves with resilient-seated gate valves or ball shut-off valves on each side of the check valves, plus properly located test cocks for the testing of each check valve. To be approved, these devices must be readily accessible for in-line testing and maintenance. 4. "Double check valve with intermediate atmospheric vent" means a device having two spring loaded check valves separated by an atmospheric vent chamber. 5. "Double detector check valve assembly" means an assembly consisting of a double check valve assembly in parallel with a bypass line assembly consisting of a water meter in series with a double check valve, and two ball shut-off valves. These devices are commonly used for low hazard fire sprinkler systems. 6. "Pressure vacuum breaker" means a device containing one or two independently operated spring loaded check valves and an independently operated spring loaded air inlet valve located on the discharge side of the check or checks. The device includes resilient-seated or ball shut-off valves on each side of the check valves and properly located test cocks for the testing of the check-valve(s). These devices are not suitable for protection against back-pressure events. 7. "Reduced pressure principle backflow preventer" means an assembly consisting of two independently operating approved check valves with an automatically operating differential relief valve located between the two check valves, and resilient-seated or ball shut-off valves on each side of the check valves, plus properly located test cocks for the testing of the check valves and the relief valve. 8. "Reduced pressure principle detector backflow preventer" means an assembly consisting of a reduced pressure principle backflow preventer in parallel with a bypass line assembly consisting of a water meter in series with a reduced pressure principle backflow preventor, and two ball shut-off valves. These devices are commonly used for high hazard fire sprinkler systems. H. "Backpressure" means a condition in which the consumer's system pressure is greater than the supplier's system pressure. I. "Back-siphonage" means the flow of water or other liquids, mixtures or substances into the distribution pipes of a potable water supply system from any source other than its intended source, caused by the sudden reduction of pressure in the potable water supply system. J. "City" means the governing body of the city of Casper, Wyoming. K. "Consumer" means any residential, commercial, industrial owner, or other user of water where the water supply is physically connected to the public potable water system. L. "Containment" means a method of backflow prevention which requires a backflow preventer at the water service entrance. M. "Contaminant" means a substance that will impair the quality of the water to a degree that creates a serious health hazard to the public or that may lead to poisoning or the spread of disease. N. "Cross-connection" means any actual or potential connection between the public water supply and a source of contamination or pollution. O. "Domestic non-residential consumer" means water service connections using potable water for ordinary living processes and not for commercial or industrial uses. Examples of domestic non-residential consumers include, but are not limited to: churches, office buildings, schools, and commercial and industrial businesses with only toilet and domestic kitchen facilities (no potable water used anywhere in operations). P. "Domestic non-residential fire sprinkler system" means a fire sprinkler system installed for a domestic non-residential consumer. Fire sprinkler systems installed for a domestic non-residential consumer with a water service line and meter one-inch in size or smaller may be integral to the building plumbing system if allowed by building code or be a separate fire sprinkler system. In cases where the fire sprinkler system is separate and can be accommodated by a water service line and meter one-inch in size or smaller, it shall be connected after the incoming water meter for the building. Q. "Fixture isolation" means a method of backflow prevention in which a backflow preventer is located to correct a cross-connection at an in-plant location rather than at a water service entrance. R. "Hazard classification" means a determination by a hazard classification surveyor as to high hazard or low hazard and the potential cause of backflow as either back-pressure or back-siphonage. S. "Hazard classification survey" means an inspection of a premise to identify the potable water system, the location of any potential cross connections to the potable water system, the hazard of the potential backflow, the physical identification of any backflow devices or methods present and the inspection status of any backflow devices or methods. The hazard classification survey results must be recorded and certified by a qualified hazard classification surveyor. T. "Hazard classification surveyor" means an individual who is certified by one of the following: the USC-Foundation for Cross-Connection Control and Hydraulic Research as a cross connection control specialist, the American Association of Sanitary Engineers (ASSE) as a cross connection control surveyor, a Wyoming or other state certification program approved by the state department of environmental quality, or by a water distribution system operator also certified as a backflow device tester employed by the city. typically, the surveyor will be the city plumbing inspector and/or city public utilities water distribution staff. U. "Industrial fluid" means a fluid or solution which may be chemically, biologically, or otherwise contaminated or polluted in a form or concentration such as would constitute a health, system, pollution or plumbing hazard if introduced into an approved water supply. This may include, but is not limited to: polluted or contaminated waters; all types of process waters and "used waters" originating from the public potable water system which may have deteriorated in sanitary quality; chemicals in fluid form; plating acids and alkalies, circulating cooling waters connected to an open cooling tower and/or cooling towers that are chemically or biologically treated or stabilized with toxic substances; contaminated natural waters such as from wells, springs, streams, rivers, bays, harbors, seas, irrigation canals or systems, etc.; oils, gases, glycerine, paraffins, caustic and acid solutions and other liquid and gaseous fluids used in industrial or other purposes or for firefighting purposes. V. "Owner" means any person who has legal title to, or license to operate or habitat in, a property upon which a cross-connection inspection is to be made or upon which a cross-connection is present. W. "Pollutant" means a foreign substance that, if permitted to get into the public water system, will degrade the quality of the potable water supply so as to constitute a moderate hazard, or impair the usefulness or quality of the water to a degree which does not create an actual hazard to the public health, but which does adversely and unreasonably effect such water for domestic use. X. "Residential fire sprinkler system" means a fire sprinkler system installed for a residence having a water service line and meter one-inch in size or smaller. The fire sprinkler system may be integral to the residence plumbing system if allowed by building code or be a separate fire sprinkler system. In cases where the fire sprinkler system is separate, it shall be connected after the incoming water meter for the residence. Y. "Used water" means the condition of water purveyors' supplied water after it has passed through the point of delivery of the customer's water system, the used water being no longer under the sanitary control of the water purveyor. Z. "Water purveyor" means the city of Casper in this chapter. AA. "Water service connection" means the terminal end of a service connection from the public potable water system, i.e., the point at which the water purveyor loses jurisdiction and sanitary control over the water, said point being the point of delivery to the customer's water system (service connection curb stop). There shall be no connections to the service line ahead of any meter or backflow prevention device located on the customer's water system. Service connection shall also include water service connection from a fire hydrant and all other temporary or emergency water service connections from the public potable water system.

(Ord. No. 13-13, 6-4-2013)

Ask a question about Casper law

Corpus searches the Casper sections it holds and shows the ones that match, with their citations. Free, no sign-in.