13.17.100 - Periodic testing.

A. It shall be the duty of the consumer at any commercial or industrial establishment where backflow prevention devices are installed to have certified inspections and operational tests made at least once every year. In those instances where the administrator deems the hazard classification to be great enough he may require certified inspections at more frequent intervals. Double check valves used for residential or domestic non-residential fire sprinkler systems with water service lines and meters one-inch in size or smaller will not have to be tested. However, it is up to the owner to ensure the device is working. B. Periodic inspections and tests shall be at the sole expense of the consumer. C. Inspections shall be performed by a backflow assembly tester as certified (Section 13.17.050(F). It shall be the duty of the consumer to see that these tests are made in a timely manner, and that the results of these tests are submitted to the administrator within one-month of the expiration of the prescribed time period, the actual test having been performed not more than three months prior to the expiration of the prescribed time period. D. Any backflow preventer which fails during a periodic test shall be repaired or replaced at the expense of the consumer. When repairs are necessary, upon completion of the repair the device will be retested at owners' expense to insure correct operation. High hazard situations will not be allowed to continue unprotected if the backflow preventer fails the test and cannot be repaired immediately unless a short compliance date is granted by the administrator. In other low hazard situations, a compliance date of not more than thirty days after the test date will be established by the administrator. The consumer is responsible for spare parts, repair tools or a replacement device. E. Backflow prevention devices will be tested more frequently than specified in Section 13.17.100 in cases where the hazard classification indicates a high hazard or there is a history of test failures. The administrator shall determine the testing schedule based upon the degree of hazard. Cost of the additional tests will be borne by the consumer.

(Ord. No. 13-13, 6-4-2013)

Ask a question about Casper law

Corpus searches the Casper sections it holds and shows the ones that match, with their citations. Free, no sign-in.