§ 13.32.120 — Grease interceptors—Specific requirements
Municipal Code of the City of Casper, Wyoming (Codified through Ordinance No. 06-26, adopted July 7, 2026. (Supp. No. 97)) · Casper Municipal Code § 13.32.120
Corpus is an independent public-information project, not the official City of Casper website. Stable reference: corpuslaw.us/code/aaefd8b6-a32d-4573-a489-13cee0d08c16
13.32.120 - Grease interceptors—Specific requirements.
A. Grease interceptors shall provide for and meet the following requirements: 1. Wastes discharged from fixtures and equipment in establishments which may contain grease, including, but not limited to, scullery sinks, pot and pan sinks, dishwashing machines, soup kettles, and floor drains located in areas where grease-containing equipment may exist, shall be drained through grease interceptors. Drains from toilets, restroom sinks, and showers shall not be connected to the grease interceptor, but shall connect to the POTW separately from any grease interceptor installation. 2. Garbage grinders shall not be connected to grease interceptors, shall not be used for disposal of any grease/oil, and shall connect to the POTW separately from any grease interceptor installation. 3. All grease interceptors shall be installed and connected in such a manner as to at all times be easily accessible for inspection, cleaning, and removal of the intercepted grease. A grease interceptor may not be installed near food-handling facilities. Outside grease interceptors shall be designed for traffic loading as referenced in Section 13.32.150(A)(5). 4. When required as per Section 13.32.100(B), grease interceptors shall contain two compartments, and shall be located outside the building on private property. 5. Grease interceptors may be constructed of cast iron, steel, reinforced fiberglass, or concrete. 6. Generally, the minimum cleaning frequency of any outdoor interceptor shall be quarterly, (ninety-day period) or semiannually (six-month period), or as directed by the city. A written record of all cleaning shall be kept on-site for verification purposes. The cleaning frequency shall be more frequent, if grease trap loading is exceeded or the city's POTW is blocked or indicates heavy accumulation of grease. 7. The city may not require installation of an interceptor for facilities that do not cook the food that is served, and do not wash equipment or utensils associated with the preparation or service of cooked food. B. When determining the minimum size of a required interceptor, the following will be considered (these sizing criteria represent minimum requirements and do not reflect special circumstances, which may necessitate increased sizing): 1. The minimum acceptable volume shall not be less than seven hundred fifty gallons (with automatic dishwasher not less than one thousand gallons). 2. The following table will determine a total rate of flow in gallons per minute from kitchen facilities, based on a fixture unit count. Using this flow, the required size of the grease interceptor can be estimated. The total rate of flow shall be multiplied by fifteen minutes of minimum retention time, with the resulting volume expressed in gallons. Size of Interceptor—Total Flow Rate Times Fifteen Minutes of Retention Time. Type of Fixture | Flow Rate, In G.P.M. Floor drain/sink | 10 Restaurant kitchen sink | 15 Single-compartment sink | 20 Double-compartment sink | 25 Three-compartment sinks | 35 2 Single-compartment sinks | 25 2 Double-compartment sinks | 35 2 Three-compartment sinks | 45 Dishwasher for restaurants: Up to 30 gallon water capacity | 15 30 to 50 gallon water capacity | 25 50 to 100 gallon water capacity | 40 3. The city will consider alternate interceptor designs, based on a minimum retention time of fifteen minutes and a minimum total water capacity of seven hundred fifty gallons. Other combinations of tank dimensions may be submitted to the city for approval. Any alternate design shall have the same basic proportional dimensions, comparable volumes, and functional capabilities as outlined in Figure 1 at the end of this chapter. C. Grease interceptors within buildings may be allowed for existing buildings where renovations are proposed and an outside interceptor is not feasible to install due to space problems if the following conditions are met: 1. Sufficient ventilation is provided to remove potential odors; 2. Outside access for cleaning; 3. Sufficient space around interceptor to allow for proper cleaning of the interceptor; 4. A monthly cleaning schedule is followed and a written record of all maintenance shall be available on-site. D. The sizing of inside traps will be determined by the city on a case-by-case basis.
(Ord. 56-00 (part), 2000)
Ask a question about Casper law
Corpus searches the Casper sections it holds and shows the ones that match, with their citations. Free, no sign-in.