§ 13.32.150 — Grease, oil and sand interceptor—Construction specifications
Municipal Code of the City of Casper, Wyoming (Codified through Ordinance No. 06-26, adopted July 7, 2026. (Supp. No. 97)) · Casper Municipal Code § 13.32.150
Corpus is an independent public-information project, not the official City of Casper website. Stable reference: corpuslaw.us/code/26ca9bd7-f3b8-49f1-ba05-6f8e3ac44e26
13.32.150 - Grease, oil and sand interceptor—Construction specifications.
A. The following apply to the construction of interceptors: 1. The standards set forth in Figures 1 through 4 at the end of this chapter are shown to convey the conceptual standard dimensional requirements for interceptors. 2. The volume of the secondary compartment shall be one-third of the total capacity. 3. Walls, bottom and top shall be constructed for the appropriate traffic loads and solid loads and shall be water tight. 4. All rebar for reinforced concrete interceptors shall have a two-inch minimum cover to the outside concrete surface. 5. Designs shall be submitted for approval and shall be certified by a licensed engineer. 6. Inlet and outlet pipe sizes shall be determined by user's or owner's architect/engineer, but shall not be less than four-inch diameter. The outlet pipe invert is to be two inches lower than inlet pipe. 7. Closed compartments shall be vented in accordance with Uniform Plumbing Code requirements. 8. All joints in pre-cast sections shall be sealed with flexible sealing compound. 9. Vent pipe materials and location shall be in accordance with the Uniform Plumbing Code. 10. The top slab may be of one-piece construction or of multiple segment construction, at the discretion of the owner. 11. The drawings (Figures 1 through 4) as found at the end of this chapter are not to scale.
(Ord. 56-00 (part), 2000)
Ask a question about Casper law
Corpus searches the Casper sections it holds and shows the ones that match, with their citations. Free, no sign-in.