§ 30.15 — OIL BURNER INSTALLATIONS FOR DRAFT BURNERS
Madison General Ordinances (Rev. 28, Update 3: codified through ORD-26-00040, published August 3, 2026) · Madison General Ordinances § 30.15
Corpus is an independent public-information project, not the official City of Madison website. Stable reference: corpuslaw.us/code/04060f6e-8dd7-4653-aa3f-c36a51763e1b
30.15 - OIL BURNER INSTALLATIONS FOR DRAFT BURNERS.
The construction, arrangement and manner of installation of all oil burners and oil burner equipment hereafter installed for use in connection with heating systems, and the alteration and repair hereafter of all oil burners and oil burner equipment used or to be used in connection with heating systems, shall conform to the following provisions: (1) Oil Burners and Oil Burner Equipment Defined. For the purpose of this Ordinance, the term "oil burner" shall mean any device for use in connection with a system designed to burn fuel oil having a flash point of one hundred (100) degrees Fahrenheit, or higher, as determined by the Tag Closed Tester in accordance with the method of test adopted by the American Society for Testing Materials (A.S.T.M. Designation D56-21), and having a fuel tank or container with a capacity of more than ten (10) gallons connected thereto. The term "oil burner equipment" shall include oil burners, as above defined, and all tanks, piping, pumps, control devices and accessories, connected to the burners. (2) Approval of Oil Burner. (a) It shall be unlawful for any person, firm, corporation or their agents, to install any oil burner which has not been approved by the National Board of Fire Underwriters' Laboratory or any other nationally recognized inspection board or laboratory. Any burner which does not meet the above requirements shall not be installed until a certificate of approval has been issued. (b) Application for approval shall give the following information: Name of burner, name and address of manufacturer, fuel recommended for burner, past history of company and burner, furnish detailed drawings and specification sheets. (3) Installation of Oil Burners. (a) All oil burners shall be installed according to the recommendations of the manufacturer. Combustion chambers shall be of proper size and design to meet requirements of firing rate of boiler or furnace. (b) Where oil burners are installed in furnaces, originally designed for solid fuel, the ash door of the furnace shall be removed or bottom ventilation otherwise provided to prevent the re-accumulation of vapors in the ash pit, unless the burner is of a type which mechanically purges the ash pit. (c) Rooms in which oil burners are located shall be provided with adequate ventilation to assure continuous, complete combustion of the oil. (4) Gravity Feed to Burners. Gravity feed shall be used only with burners arranged to prevent abnormal discharge of oil at the burner by automatic means specifically approved for the burner with which it is used.
Ask a question about Madison law
Corpus searches the Madison sections it holds and shows the ones that match, with their citations. Free, no sign-in.