§ 18-28-507.9 — Clearances for Type I hood
Municipal Code of Chicago (2026 S-74, current through Council Journal of June 17, 2026) · Municipal Code of Chicago § 18-28-507.9
Corpus is an independent public-information project, not the official City of Chicago website. Stable reference: corpuslaw.us/code/09584dc3-124a-4be7-8768-fae75d3956f2
18-28-507.9 Clearances for Type I hood.
A Type I hood shall be installed with a clearance to combustibles of not less than 18 inches (457 mm). Exception: Clearance shall not be required from gypsum wallboard attached to noncombustible structures provided that a smooth, cleanable, nonabsorbent and noncombustible material is installed between the hood and the gypsum wallboard over an area extending not less than 18 inches (457 mm) in all directions from the hood.