30.06 - WARM AIR.

(1) Selection of Furnace or Rooftop Unit Size. The furnace or rooftop unit shall be selected to satisfy the maximum hourly BTU requirement of the building and shall have a register delivery rating determined by a recognized authority. If the manufacturer's rating is given as a rating at the bonnet, the rating at the register shall be determined by the following method: To obtain the register rating on a gravity furnace, the BTU rating at the bonnet shall be reduced by twenty-five percent (25%); on forced warm air furnaces, bonnet rating shall be reduced by fifteen percent (15%). (2) Selection of Blower Capacity. The blower shall be selected to furnish the required CFM air delivery against the total static pressure of the system, equal to or greater than the sum or the CFM requirements of all spaces to be heated. (3) Selection of Ducts, Registers, Intakes. (a) Gravity system less than one hundred fifty thousand (150,000) BTU per hour. The system of branches, risers, fittings, registers, intakes and trunk ducts to be installed shall meet the minimum requirements resulting from the use of Manual No. 5, of the N.W.A.H.A.C. Association, as listed in Appendix No. 1. (b) Forced warm air system not in excess of one hundred twenty thousand (120,000) BTU per hour. The system of branches, risers, fittings, registers, intakes and trunk ducts to be installed shall meet the minimum requirements resulting from use of Manual No. 7, of N.W.A.H.A.C. Association, as listed in Appendix No. 1. (c) Forced warm air system in excess of one hundred twenty thousand (120,000) BTU per hour. The system of branches, risers, fittings, registers, intakes and trunk ducts to be installed shall meet the minimum requirements resulting from the use of Tables of Manual No. 9, N.W.A.H.A.C. Association as listed in Appendix No. 1. (d) Individual return air intakes in new residential construction shall be installed from each room excepting bathrooms, kitchens and utility rooms. This shall include all heated recreation and playrooms. In kitchens with a dining area, return air intake shall be installed. However, in the case of one (1) story dwellings with either a crawl space or a full basement, and where baseboard warm air heating is used, direct return airs may be eliminated from the bedrooms providing: 1. Air is transferred at the floor level to a return air grille located in the connecting hall or corridor. 2. The free area of the said return air grilles shall be sized to equal one hundred percent (100%) of the required area of the supply ducts. 3. The said grille to be located at the floor level with a velocity not to exceed five hundred ninety-nine (599) feet per minute. 4. Air shall not be transferred from one habitable room through another habitable room. (e) Selection of the return air ducts size shall be sized for at least one hundred percent (100%) of the area of the supply duct system. Where return air is taken from more than one (1) story and where high sidewall returns are used, at least fifty percent (50%) of those located on the lowest story must be located at the floor level. (4) Furnace Location and Mounting. (a) Accessibility. Furnaces shall be so located that all parts which require periodical service or replacement are easily accessible with a minimum clearance of twenty-four (24) inches, except for a closet installation, a door or access panel which will open the full size of equipment may be used. (b) Pipeless Furnaces. Placement. Locate so that no door, drapery, or similar object can be nearer than twelve (12) inches to any portion of the floor, furnace or register. (c) Floor Furnaces. 1. Placement. Locate so that no door, drapery, or similar object can be nearer than twelve (12) inches to any portion of the floor, furnace or register. 2. Bracing. The floor around the furnace shall be braced and headed with a framework of material not lighter than the joists. The inside dimensions of the framework shall be approximately one-half (½) inch longer and one-half (½) inch wider than the furnace to be installed. 3. Support. Means shall be provided to support the furnace when the floor grille is removed. 4. Clearance. The bottom of the floor furnace shall have at least a six (6) inch clearance from the ground, obtained, when necessary, by excavating the ground below and to the sides to form a "basin-like" pit under the furnace so that there is a six (6) inch clearance beneath the furnace and a twelve (12) inch clearance on all sides, except the control side, which shall have an eighteen (18) inch clearance. 5. Seepage Pan. Whenever the excavation exceeds twelve (12) inches and water seepage is apparent under the house, a water-tight copper pan, concrete pit, or other suitable material shall be used. If of copper, it shall be made of not less than sixteen (16) ounces sheet copper. The pan shall extend at least four (4) inches above the ground level, with a twelve (1) inch clearance from the furnace on all sides, except the control side, which shall have an eighteen (18) inch clearance. 6. Access. Adequate provision shall be made for easy access to the furnace under the house by means of an opening in the foundation wall or through a trap door of at least thirty by thirty (30 x 30) inches, located at some convenient point in the house, and a clear, unobstructed passageway to the furnace at least thirty by thirty (30 x 30) inches. 7. Appliance Alterations. All gas floor furnaces, including those having single or dual wall register outlets, shall be installed without alterations, extensions, or changes of any kind in the furnace. 8. Upper Floor Installations. Gas floor furnaces may be installed in an upper floor provided the furnace assembly projects below into a utility room, closet, garage, or similar nonhabitable space. In such installations, the furnace shall be enclosed completely, with provisions for service, with furnace clearances of six (6) inches on all sides and bottom, and with the enclosure constructed of Portland cement plaster on metal lath or material of equal fire resistance. Sufficient air for combustion must be supplied. (d) Recessed Heaters. 1. Installation. Recessed heaters shall be installed in accordance with Sections 30.18, 30.19, 30.20 and 30.21 of the Madison General Ordinances. 2. Location. Recessed heaters shall be located so as not to cause a hazard to walls, floors, curtains, furniture, doors, etc. Recessed heaters installed between bathroom and adjoining rooms shall not circulate air from bathroom to other parts of the building. (e) Mounting Furnaces. 1. For Incombustible Floor. Furnaces shall be mounted on a firm, level base of brick, cement or other incombustible material; tightly sealed at the bottom of the casing, or suspended or supported in a rigid manner. Said base shall be directly on the ground or adequately supported. 2. High Boy, Forced Air Furnace on Combustible Floor. Automatically fired, forced warm air furnaces may be mounted on a combustible floor provided they are so arranged that the fan and fan chamber occupies the entire area beneath the firing chamber and forms a well ventilated air space between the firing chamber and the floor. 3. Furnaces With Legs on Combustible Floor. Warm air furnaces and heaters which have four (4) inches or more of open space under the base of the appliance may be mounted on combustible floors, provided the appliance is such that flame or hot gases do not come in contact with its base, and further provided, the floor under the appliance is protected with not less than one-fourth (¼) inch of asbestos mill board or equally covered with sheet metal of not less than No. 24 U.S. gauge. The above specified floor protection shall extend not less than the clearances specified in Section 30.06(4)(f) 2, 3, and 4 of the Madison General Ordinances. 4. Downflow Furnace on Combustible Floor. A downflow furnace installed in a combustible floor must be set over a plenum of proper size, and both the furnace and the plenum must be supported by a base of one (1) inch thick asbestos mill board, building tile or cinder block. The plenum must be suspended from the top of the noncombustible base, and a clearance of at least one (1) inch must be provided between the outer sides of the plenum and the wood framing around the opening in the floor. This one (1) inch space must be filled with noncombustible insulation. When oil-fired equipment is to be installed, the floor protection must extend beyond the burner and must be covered with a drip pan at least one (1) inch deep to prevent oil saturation of the combustible floor. On all downflow furnaces there shall be installed an additional high limit control to close down the burner if there should be blower failure. (f) Installation Clearances. 1. Furnace Clearances, by Temperature. Locate furnace so as to maintain a clearance sufficient to prevent surface temperatures of adjacent combustible materials, not to exceed one hundred seventy-five (175) degrees Fahrenheit. 2. Furnace Clearance, by Inches. No Protection. Except as otherwise provided, warm air furnaces and heat exchangers shall be installed to provide a clearance to woodwork or other combustible material, whether plastered or unplastered, not less than as shown in Table 1. Note 1. Front clearance shall be sufficient for servicing the burner and furnace. Note 2. Listed limit control that cannot be set higher than two hundred fifty (250) degrees Fahrenheit installed not more than ten (10) inches above the top surface of heat exchanger in a supply plenum that extends at least twelve (12) inches above the top surface of the heat exchanger. Note 3. Barometric draft control operated by draft intensity and permanently set to limit the draft to a maximum intensity of thirteen-hundredths (0.13) inches of water gauge. Note 4. Clearance above supply ducts within three (3) feet of the plenum shall be not less than one (1) inch. See Section 30.06(4)(f)5. of the Madison General Ordinances. Note 5. Clearance above supply ducts within six (6) feet of the plenum shall be not less than that specified above the bonnet or plenum. See Section 30.06(4)(f)5. of the Madison General Ordinances. Note 6. Clearance above horizontal supply ducts within three (3) feet of the plenum shall be not less than eighteen (18) inches, and beyond six (6) feet, not less than one (1) inch. 3. Furnaces in Closets, etc. Furnaces shall not be installed in a confined space such as an alcove or closet unless specifically approved for such installation and then only when installed in compliance with the approval and with the clearance from the walls and ceiling of the alcove or closet, not less than specified regardless of the type of construction. TABLE NO. 1 Minimum Clearance, Inches Above and Sides of Bonnet or Plenum | Jacket Sides and Rear | Front Note 1 I. | Listed or unlisted automatically fired, forced air or gravity system, equipped with 250 degrees Fahrenheit temperature limit control installed in accordance with Note 2. | 24 Burning Liquid Fuel (See Note 4) | 1 | 6 | 24 Burning Gas Fuel (See Note 4) | 1 | 6 | 18 Utilizing Electricity (See Note 4) | 1 | 6 | 18 II. | Listed automatically fired, forced air or gravity system, equipped with limit control not conforming to Note 2, but that will limit outlet air temperature to 250 degrees Fahrenheit (See Note 5). Burning Liquid Fuel | 2 | 6 | 24 Burning Gas Fuel | 2 | 6 | 18 Utilizing Electricity | 2 | 6 | 18 III. | Steam or Hot Water Heat Exchanger. Steam not over 15 pounds gauge pressure and hot water not more than 250 degrees Fahrenheit. | 1 | 1 | 1 IV. | Automatically stoker fired, forced air system equipped with 250 degrees Fahrenheit temperature limit control installed in accordance with Note 2 and barometric draft control (See Notes 3 and 5). Burning Solid Fuel | 6 | 6 | 48 V. | Furnaces other than above (See Note 6) Burning Liquid Fuel | 18 | 18 | 48 Burning Gas Fuel | 18 | 18 | 18 Burning Solid Fuel | 18 | 18 | 48 TABLE NO. 2 REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTION Where required clearance w/no protection from appliance, vent connector, or single wall metal pipe is: Type of protection applied to & covering all surfaces of combustible material w/in distance specified as required clearance w/no protection (See Figs. 7, 8, 9) | 36" | 18" | 12" | 9" | 6" Allowable Clearances w/Specified Protection, inches Above | Sides and Rear | Above | Sides and Rear | Above | Sides and Rear | Above | Sides and Rear | Above | Sides and Rear a) 3½" thick masonry wall w/out ventilated air space | — | 24 | — | 12 | — | 9 | — | 6 | — | 5 b) ½" insulation board over 1" glass fiber or mineral wool batts | 24 | 18 | 12 | 9 | 9 | 6 | 6 | 5 | 4 | 3 c) 0.024 (24 gauge) sheet metal over 1" glass fiber or mineral wool batts reinforced w/wire on rear face w/ventilated air space | 18 | 12 | 9 | 6 | 6 | 4 | 5 | 3 | 3 | 3 d) 3½" thick masonry wall w/ventilated air space | — | 12 | — | 6 | — | 6 | — | 6 | — | 6 e) 0.024 (24 gauge) sheet metal w/ventilated air space | 18 | 12 | 9 | 6 | 6 | 4 | 5 | 3 | 3 | 2 f) ½" thick insulation board w/ventilated air space | 18 | 12 | 9 | 6 | 6 | 4 | 5 | 3 | 3 | 3 g) 0.024 (24 gauge) sheet metal w/ventilated air space over 0.024 (24 gauge) sheet metal w/ventilated air space | 18 | 12 | 9 | 6 | 6 | 4 | 5 | 3 | 3 | 3 h) 1" glass fiber or mineral wool batts sandwiched between two sheets 0.024 (24 gauge) sheet metal w/ventilated air space | 18 | 12 | 9 | 6 | 6 | 4 | 5 | 3 | 3 | 3 _____ NOTES APPLICABLE TO TABLE 2 1. Reduction of clearances from combustible materials shall not interfere with combustion air, draft hood clearance and relief, and accessibility of servicing. 2. All clearances shall be measured from the outer surface of the combustible material to the nearest point on the surface of the appliance, disregarding any intervening protection applied to the combustible material. 3. Spacers and ties shall be of noncombustible material. No spacer or tie shall be used directly opposite appliance or connector. 4. With all clearance reduction systems using a ventilated air space, adequate provision for air circulation shall be provided as described. (See Figures 7 and 8.) 5. There shall be at least 1 inch between clearance reduction system and combustible walls and ceilings for reduction systems using ventilated air space. 6. If a wall protector is mounted on a single flat wall away from corners, adequate air circulation may be provided by leaving only the bottom and top edges or only the side and top edges open with at least 1 inch air gap. 7. Mineral wool batts (blanket or board) shall have a minimum density of 8 lb/ft 3 and a minimum melting point of 1500/F. 8. Insulation material used as part of clearance reduction system shall have a thermal conductivity of 1.0 (Btu-in)/(sq ft-hr-F) or less. 9. There shall be at least 1 inch between the appliance and the protector. In no case shall the clearance between the appliance and the combustible surface be reduced below that allowed in the table. 10. All clearances and thicknesses are minimum; larger clearances and thicknesses are acceptable. 4. Furnace Clearances - By Inches - With Protection. Warm air furnaces may be installed with clearances to woodwork or other combustible material, as shown in Table 2, where the combustible material or the appliance is protected as described in Table 2. 5. Duct Clearances. All parts of the supply system exposed to radiated heat from a furnace or surface, the temperature of which may be higher than two hundred fifty (250) degrees Fahrenheit, shall be constructed, insulated, shielded, or otherwise arranged, so that the temperature of the combustible construction adjacent to the supply system is not raised above one hundred seventy-five (175) degrees Fahrenheit. Horizontal Supply Duct Clearances. Within a distance of three (3) feet of the plenum of systems classified under Items I and III of Table 1, the clearance shall be not less than one (1) inch. Beyond three (3) feet, no clearance is required. Within a distance of six (6) feet of the plenum of a system classified under Items II, IV, and V of Table 1, the clearances shall be not less than specified above the bonnet of plenum. Beyond six (6) feet, no clearance is required. From ducts of furnaces classified under Item IV of Table 1, the clearance shall be not less than six (6) inches out to six (6) feet and one (1) inch beyond six (6) feet to a point where there is a change of direction equivalent to ninety (90) degrees or more. Where a horizontal supply duct passes through or pierces a partition or enclosure constructed of combustible material, the clearance shall be not less than specified in this section. The ends of the space providing this clearance may be closed with a thimble and collar or the wall surfaces extended to the duct with incombustible building material such as plaster on metal lath. Vertical Supply Ducts, Risers, Boots and Register Box Clearance. Where a duct, riser, boot or box in a system that does not require an eighteen (18) inch clearance above the supply plenum or bonnet enters a floor, partition or enclosure constructed of combustible material within the distance from the plenum specified in this section, the clearance from such duct, riser or boot shall be not less than the distance required above the furnace bonnet of plenum (See Table 1) or the duct shall change direction equivalent to at least ninety (90) degree turns before entering such floor, partition or enclosure. The above does not apply to pipeless furnaces covered hereinafter in this section. Where a supply duct enters the floor of the first story above that in which the furnace is located, the space around the duct at such points shall be sealed with asbestos cement or other incombustible material. Pipeless Furnace Registers. Where registers are installed in the floor over the furnace (as in the "pipeless" furnace) the register box shall be constructed double with an air space not less than four (4) inches between except where the warm air passage is surrounded by a cold air passage. Where warm air ducts are exposed in closets, they shall be covered with not less than one-fourth (¼) inch air seal asbestos or its equivalent in approved fire-resistive insulating covering, properly protected against injury.

(Sec. 30.06(4)(f)3. Table 2 R. & Re-Cr. by Ord. 10,255, Adopted 5-7-91)

Ask a question about Madison law

Corpus searches the Madison sections it holds and shows the ones that match, with their citations. Free, no sign-in.